I want to search for...
Permit #2009110455
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00530-0040 |
| CONDITIONED SPACE: 2100 sqft |
| GARAGE: 426 sqft |
| OPENED PORCH (WITH ROOF) : 176 sqft |
| OPENED PORCH (WITH ROOF) : 71 sqft |
| Total Square Footage: 2773 sqft |
| Block: 00530 |
| Subdivision: - |
| Job Phone: 386-246-6125 |
| Location Address: 20 WHEATFIELD DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/07/2009 |
| NOC: RECORDED |
| Applicant name: BRIAN ANDREW GAZZOLI |
| Owner: SEAGATE HOMES LLC |
|
Address 185 CYPRESS POINT PKWY PALM COAST, FL 32164 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤177,891.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SEAGATE HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
185 CYPRESS POINT PARKWAY Palm Coast, FL 32137 |
SUITE 7 Palm Coast, FL 32137 |
CRC057202 (Exp: 08/31/2010) | 386-246-6125 | 386-246-6124 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 04/01/2010 | FINAL APPROVED | ACOOPER |
| Note: 4/1/10 (PA) - LANDSCAPE OK | |||
| STORMWATER FINAL INSPECTION | 03/30/2010 | APPROVED | JCOLASANTI |
| Note: no road or swale damage 11/30/09 | |||
| UTILITY COMPANY FINAL | 03/26/2010 | APPROVED | TSCHWEERS |
| R.O.W. DAMAGE INSPECTION | 03/24/2010 | CANCELLED BY INSPECTOR | JCOLASANTI |
| Note: Please mark road for necessary repairs 3/24/10 unable to make assesssment//road is blocked and needs sweeping/jc/la | |||
| PRE DRIVEWAY | 03/10/2010 | APPROVED - AS NOTED | JCOLASANTI |
| Note: concrete needs to be 5" if within 15' of the EOP per JC.\\wk | |||
| RESIDENTIAL EARLY POWER | 03/04/2010 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 3/4/2010 11:03:12 AM CALLED FPL. PALMETTO ELECTRIC. | |||
| LATH /BRICK FLASHING | 02/17/2010 | APPROVED | ACOOPER |
| INSULATION INSPECTION | 02/12/2010 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 02/11/2010 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 2/11/2010 3:21:15 PM PROPERLY FIRE BLOCK ABOVE PANEL. BOTH SIDE WALLS AT FRONT ENTRANCE NEED TO BE FURRED TO BLOCK FOR PROPER FIRE BLOCKING. | |||
| ALL ROUGH | 02/09/2010 | APPROVED | JHINDMAN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/08/2010 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/04/2010 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/4/2010 3:50:49 PM ADD ENGINEERING TRUSS A4, STRAP INTERIOR BEARING WALLS FOR CONTINUOUS LOAD PATH (SEE GREEN PAINT), BLOCK OSB LAID VERTICALLY ON ENDS AND ADD 2X4S ON GABLE ENDS TO MAINTAIN 24" SPREAD PER MANUFACTURER, ADD FRONT PORCH GABLE END ENGINEERING, ADD STRONGBACK BRIDGING PER PLAN (9.1 AND TRUSS MANUFACTURER) | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/02/2010 | CANCELLED BY APPLICANT | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Requested at 2/1/2010 6:37:45 PM PLEASE MAKE AFTERNOON INSP Inspection Resulted at 2/2/2010 8:00:40 AM THEY CALLED JERRY HINDMAN TO CANCEL THIS INSPECTION. | |||
| RESIDENTIAL EARLY POWER | 02/02/2010 | CANCELLED BY APPLICANT | AIRS WEB |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/01/2010 | CANCELLED BY APPLICANT | RMARVEL |
| LINTEL | 01/21/2010 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 01/20/2010 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 1/20/2010 2:14:50 PM EPOXY ON DRILLED DOWELS NOT PROPERLY MIXED. | |||
| FOUNDATION SURVEY APPROVED BY ZONING | 01/19/2010 | APPROVED | BBARTON |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 01/19/2010 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/13/2010 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 01/12/2010 | APPROVED | ACOOPER |
| R.O.W. DAMAGE INSPECTION | 12/11/2009 | APPROVED - AS NOTED | JCOLASANTI |
| Note: 12/10/09 please note existing road damage (applicant reports cracking in roadway frontage)//la 12/11/09 jc noted road damage next door at #18//normal asphalt cracking at #20//remove port o let form swale 1/13/09 port o let in swale//silt fence up |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/04/2009 | 12/04/2009 |
| PLUM | COMPLETE | 12/04/2009 | 12/04/2009 |
| MECH | COMPLETE | 12/04/2009 | 12/04/2009 |
| ELEC | COMPLETE | 12/04/2009 | 12/04/2009 |
| ELEC | HOLD | 11/24/2009 | 11/24/2009 |
| Note: Electrical plans must be to current 2008 NEC | |||
| BLD | COMPLETE | 11/24/2009 | 12/04/2009 |
| SW1 | COMPLETE | 11/24/2009 | 11/25/2009 |
| Note: Joint review with wk//la | |||
| ZON | COMPLETE | 11/24/2009 | 11/24/2009 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 04/01/2010 |
| EARLY POWER INSPECTION | ¤40.00 | 04/01/2010 |
| REINSPECTION FEE | ¤40.00 | 04/01/2010 |
| REINSPECTION FEE | ¤40.00 | 04/01/2010 |
| REINSPECTION FEE | ¤40.00 | 04/01/2010 |
| NEW RESIDENTIAL INSPECTIONS | ¤355.78 | 12/07/2009 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/07/2009 |
| SITE PLAN 20 | ¤20.00 | 12/07/2009 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/07/2009 |
| TRANS IMPACT FEE 7-RESIDENTIAL | ¤3,565.34 | 12/07/2009 |
| FIRE COMM IMPACT FEE 4/1/09 | ¤190.48 | 12/07/2009 |
| MECHANICAL FEE | ¤166.73 | 12/07/2009 |
| PERMIT FEE | ¤20.00 | 12/07/2009 |
| PARKS IMPACT FEE 4/1/09 | ¤1,230.83 | 12/07/2009 |
| PLAN CHECK FEE | ¤71.16 | 12/07/2009 |
| PLUMBING FEE | ¤166.73 | 12/07/2009 |
| RADON FEE | ¤13.87 | 12/07/2009 |
| BUILDING CODE ADMIN FUND | ¤13.87 | 12/07/2009 |
| BUILDING DISCOUNT 100% | (¤852.42) | 12/07/2009 |
| ELECTRIC FEE | ¤166.73 | 12/07/2009 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,009.10 |