Permit #2009120287

Permit Details

Status: COED

Parcel Id: 02-11-30-0000-01010-0031
Total Square Footage: 2500 sqft
Block: 01010
Subdivision: -
Job Phone: (386) 445-7945
Location Address: 5455 BELLE TERRE PKWY
Type: BC - BUILDING COMMERCIAL
Issue Date: 05/25/2010
NOC: Unknown
Applicant name: RYSZARD A SKLADZIEN
Owner: CITY OF PALM COAST

Address

SUITE B-106

PALM COAST, FL 32164

Address

160 CYPRESS POINT PKWY

PALM COAST, FL 32164

Lot: 0031
Contracted Stated Job Value: ¤150,000.00
Job Description: MEETING / EQUIPMENT STORAGE BUILDING(PALM COAST LITTLE LEAGUE)
Type: CN

Contractor

RYSKCON CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
CANCEL

2 Market Place Unit D

Palm Coast, FL 32137

CGC037470 (Exp: 08/31/2014) (386) 445-7945 (386)446-3871

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
THOMAS WALTER ALBANO
Status Location Address State License Number Phone Fax
INACTIVE

P. O. BOX 352075

Palm Coast, FL 32135

CFC045991 (Exp: 08/31/2024) 386-437-2795 (386)437-2781
JOANNA S REELEY
Status Location Address State License Number Phone
INACTIVE

2 MARKET PLACE D

PALM COAST, FL 32137

CCC1327485 (Exp: 08/31/2020) 386-445-7945
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856

Inspection History

Type Request Date Result Inspector
ELECTRICAL FINAL 05/02/2012 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION REQUESTED BY CONTRACTOR
ELECTRICAL FINAL 04/25/2012 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 4/25/2012 2:42:30 PM ALL CONDUIT OUTSIDE NEED TO HAVE CORRECT WASHERS AND SEALS AND NEED TO BE GLUED.....NEED TO TORQURE GROUND LUG WIRES,HAS MOVEMENT. NEED TO PHASE OUT CONDUCTORS THAT ARE BEING USED AS HOT AND PHASE OUT CONDUCTORS THAT ARE BEING USED AS HOT..SCHEDULE ON INSIDE PANEL NEED TO BE REVISED TO MATCH.....
PLUMBING FINAL 04/25/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION
H.V.A.C. FINAL 04/25/2012 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
H.V.A.C. FINAL 03/26/2012 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 3/26/2012 2:51:51 PM DISCONNECT FOR AHU NEEDS TO BE READILY ACCESSIBLE.
PLUMBING FINAL 03/26/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 3/26/2012 3:21:47 PM POP OFF RELIEF VALVE PIPE NEEDS TO EXIT THE BUILDING.HANDICAPP SIGNS NEED TO BE INSTALLED.
ELECTRICAL FINAL 03/26/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 3/26/2012 3:21:46 PM ALL CONDUIT OUTSIDE NEED TO HAVE CORRECT WASHERS AND SEALS AND NEED TO BE GLUED....NEED TO SHOW TAP BOX ON PLAN WITH RISER DIAGRAM AND WIRE SIZES SHOWN ALSO.NEED TO TORQURE GROUND LUG WIRES,HAS MOVEMENT. NEED TO PHASE OUT CONDUCTORS THAT ARE BEING USED AS HOT AND PHASE OUT CONDUCTORS THAT ARE BEING USED AS GROUNDS...NEED TO HAVE WEATHER PROOF WIRE OUTSIDE NOT NO. 12 WIRE... DISCONNECT FOR A/C HANDLER NEEDS TO BE ACCESSABLE AND CORRECT CLEARANCE IN FRONT OF IT.......NEED TO HAVE LOCK OUT BREAKER FOR WATER HEATER...RECEPTACLES IN BREAK ROOM NEXT TO MOP SINK NEED TO BE GFCI PROTECTED...PANEL SCHEDULE ON INSIDE AND OUTSIDE PANELS NEED TO BE REVISED TO MATCH.....
HANDICAPPED RAMP INSPECTION 03/26/2012 APPROVED CMINI
BUILDING-ADA - RAMPS/SIDEWALKS/CROSSWALKS 03/26/2012 APPROVED CMINI
BUILDING-ADA- PARKING (TOTAL AND REQ. HC ACCESIBLE) 03/26/2012 APPROVED CMINI
BUILDING-ADA - REQUIRED SIGNAGE 03/26/2012 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 3/26/2012 3:21:50 PM SIGNAGE AT RESTROOMS
COMMERCIAL BUILDING FINAL 03/26/2012 APPROVED - AS NOTED CMINI
Note: REQUESTED BY CONTRACTOR Inspection Resulted at 3/26/2012 3:21:48 PM HANDICAPP SIGNS NEED TO BE INSTALLED
UTILITY COMMERCIAL FINAL 03/26/2012 APPROVED KKING
UTILITY COMPANY FINAL 03/26/2012 APPROVED KKING
FIRE FINAL 02/09/2012 APPROVED JHINDMAN
2ND ROUGH ELECTRICAL 02/09/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION
H.V.A.C. FINAL 02/09/2012 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 2/9/2012 10:16:19 AM THE CONDENSER DOES NOT FUNCTION. THE EXHAUST FAN IS HITTING THE HOUSING IN THE BATHROOM.
ELECTRIC FEEDER 12/14/2011 APPROVED LHITES
COMMERCIAL POWER INSPECTION 12/05/2011 APPROVED LHITES
Note: Inspection Resulted at 12/5/2011 10:54:46 AM CALLED SUSAN WITH FPL 9:00 AM
INSULATION INSPECTION 05/09/2011 APPROVED CMINI
2ND ROUGH ELECTRICAL 05/04/2011 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 5/4/2011 3:00:13 PM ROUGH IN EMERGENCY LIGHTS AND COUPLE SPOTS WHERE NAIL PLATES ARE NEEDED AND WIRES OFF CAN LIGHTS.CHECK ON INSULATION
2ND ROUGH ELECTRICAL 04/18/2011 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 4/18/2011 11:05:46 AM 2008 NEC ARTICAL 334.30 TO SUPPORT AND STRAP CABLE EVERY 4``..STRAP WITHIN 12" OF BOXES..RECHECK NAIL PLATES..REMOVE CABLES FROM HOUSING OF RECESSED CANS..NEED REVISION TO MATCH FROM ELECTRICAL LAYOUT ON PLANS TO WORK DONE...GROUNDS AND NEUTRALS NEED TO BE LANDED IN PANEL...
ABOVE CEILING 04/18/2011 APPROVED - AS NOTED RMARVEL
Note: Inspection Resulted at 4/18/2011 11:05:48 AM NOT APPLICABLE ALL LOOKED AT AT INDIVIDUAL INSPECTIONS
H.V.A.C. ROUGH 04/18/2011 APPROVED RMARVEL
SECOND ROUGH PLUMBING INSPECTION 04/18/2011 APPROVED RMARVEL
FRAMING 04/18/2011 APPROVED RMARVEL
FIREWALL INSPECTION 04/18/2011 APPROVED LHITES
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/27/2010 APPROVED CMINI
LINTEL 09/14/2010 APPROVED JHINDMAN
MONOLITHIC SLAB INSPECTION/SLAB 07/21/2010 APPROVED CMINI
FOOTER 07/21/2010 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 07/20/2010 APPROVED RMARVEL
FOUNDATION SURVEY APPROVED BY ZONING 07/16/2010 CANCELLED BY INSPECTOR CBENTLEY
Note: Interior to park foundation does not need setback determination.

Review History

Department Status Date In Date Out
BLD COMPLETE 05/01/2012 05/01/2012
BLD COMPLETE 04/18/2012 04/19/2012
ELEC COMPLETE 04/18/2012 04/19/2012
ELEC COMPLETE 03/23/2012 03/23/2012
BLD COMPLETE 03/23/2012 03/23/2012
BLD COMPLETE 03/06/2012 03/06/2012
ELEC HOLD 03/06/2012 03/06/2012
Note: Provide specification sheet for water fountain provide HVAC service side dimensions for minimum service accessibility
ZON COMPLETE 03/06/2012 03/08/2012
ELEC COMPLETE 05/03/2011 05/03/2011
Note: Released By: LHITES Revised electrical layout- switched from reflective light to high-hats with hard ceilings
MECH COMPLETE 11/05/2010 11/05/2010
Note: Released By: FREODICA Revision: Added a/c in storage equipment room
ZON COMPLETE 11/01/2010 11/01/2010
Note: Released By: JGONZALEZ Revised landscape plan/sidewalk layout
MECH HOLD 11/01/2010 11/01/2010
Note: Held By: FREODICA Revision: Revised a/c layout to include equipment storage w/ revised energy calcs. Comment: Provide information on what items/equipments to be stored in the equipment storage. emailed @ 3:07, 11-1-10
PLUM COMPLETE 10/04/2010 10/04/2010
Note: Released By: JMCGOWEN changed electric hot water system to solar/electric system being donated by solat fit inc documents requested by Joe Mcgowen attached
BLD COMPLETE 09/08/2010 09/08/2010
Note: Released By: FREODICA Correction to revision : Signed & sealed detail for openings using steel lintel instead of cast concrete lintel.
BLD HOLD 09/03/2010 09/03/2010
Note: Held By: FREODICA revision-plan modification replacing concrete lintels for use with steel lintels for use with split faced block Revision comments: 1. Plans & detail shall be signed & sealed by the design engineer. 2. Previous comment need to be addressed regarding steel lintel location, size and schedule. 3. Please be reminded that revision dated 7/22/10 regarding submittal of (1) missing plan copy of door schedule has not been received yet. Faxed & emailed @10:44, 9-3-10.
BLD HOLD 08/31/2010 09/01/2010
Note: Held By: JMCGOWEN revision- steel lintel over openings instead of pre cast - split face block provide steel lintel locations and size and schedule
BLD COMPLETE 08/12/2010 08/12/2010
Note: Released By: FREODICA Revision: slope removed from slab door schedule- missing # on door (door #3)
BLD HOLD 07/22/2010 07/22/2010
Note: Held By: JMCGOWEN REVISION_ revised foundation plan page two is missing on one copy, please provide
PLUM COMPLETE 07/16/2010 07/16/2010
Note: Released By: JMCGOWEN PLUMBING RISER DIAGRAM MODIFICATION
UD1 COMPLETE 07/09/2010 07/09/2010
Note: Released By: CJOHNSON LOCATION OF WATER & SEWER LINES
BLD COMPLETE 07/08/2010 07/08/2010
Note: Released By: JMCGOWEN LOCATION OF WATER & SEWER LINES
FI1 COMPLETE 05/17/2010 05/18/2010
Note: Released By: JPATTEE
BLD COMPLETE 05/17/2010 05/17/2010
Note: Released By: JMCGOWEN plumbing change on bathroom and reserving door. and fire extenquiser
PLUM COMPLETE 05/17/2010 05/17/2010
Note: Released By: JMCGOWEN plumbing changes on bathroom and reserving door and fire extension
BLD HOLD 05/05/2010 05/05/2010
Note: Held By: JMCGOWEN Modification of bathroom and electrical coordinate plumbing and building plans
ELEC COMPLETE 05/05/2010 05/05/2010
Note: Released By: JMCGOWEN
PLUM HOLD 05/05/2010 05/05/2010
Note: Held By: JMCGOWEN coordinate plumbing and building plans
FI1 HOLD 04/15/2010 04/20/2010
Note: Held By: JPATTEE 1) Door labeled #3 for storage room, reverse swing or swing in. 2) K fire extinguisher not required unless cooking produces grease laden vapors.
BLD COMPLETE 04/15/2010 04/15/2010
Note: Released By: JMCGOWEN corrections for Plumb,elec,a/c,bathroom layout
ELEC HOLD 04/15/2010 04/15/2010
Note: Held By: LHITES 1. Latest correction is missing electrical load calculation. 2. Electric riser shows single phase 120/240, panel schedule is for 3 phase 120/208 please confirm which will be used.
MECH COMPLETE 04/15/2010 04/15/2010
Note: Released By: JMCGOWEN
PLUM HOLD 04/15/2010 04/15/2010
Note: Held By: LHITES 1. Per Florida Building Code fig 30e. the required distance between sink edge and wall is 60" Also need 95" min. wall lenth at grab bar wall.
PLUM HOLD 03/26/2010 03/26/2010
Note: Held By: FREODICA 1. No plumbing plans submitted.
ELEC HOLD 03/25/2010 03/25/2010
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit App. #2009120287 (Palm Coast Little League @ 5455 Belle Terre Pkwy.) 3/25/2010 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. New Panel schedule, load calculation and riser shown on revised sheet 5/8 has removed the Life Safety plan. Provide Life Safety plan. 2. Panel schedules, load calculations, and electrical risers do not match on revised sheet 5/8, and 6/8. Coordinate. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 160 Cypress Point Pkwy Ste B106 Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
MECH HOLD 03/25/2010 03/26/2010
Note: Held By: FREODICA Correction review comments: 1. Conditioned area in square footage shown in submittted energy calculations does not match with plan. 2. Return air from break room (previously named food preparation room) and srvr. storage are still missing (previous comment item 3). 3. Outdoor air ventilation calculations (previous comment item 4). 4. Exhaust fan specifications (previous comment item 6). 5. Condensate disposal (previous comment item 7).
BLD HOLD 03/25/2010 03/25/2010
Note: Held By: JJOSEPH 1. Provide classication type of construction, occupancy and occupant load . 2. Provide column footing and footer details. Revisions as requested
MECH HOLD 02/18/2010 02/18/2010
Note: Held By: FREODICA Review comments base on corrections submittal: 1. Submitted energy calculations are not code compliant. Provide completed Form 400A-08 (generated by Energy Gauge Summit FLA/COM computer program) per FBC 2007 Sec. 13-400.3A Method A Form. 2. Provide duct sizes of main supply air (item 2 of previous comment) 3. Provide method of return air from food preparation room and srvr storage. 4. Provide calculations for the required outdoor ventilation air per FMC 2007 Table 403.3 (item 4 of previous comment) 5. Exhaust fan specifications (item 5 of previous comment) 6. Provide duct material specifications (item 6 of previous comment). 7. Provide hvac duct details such as AHU mounting, duct supports, condensate disposal etc. (item 7 of previous comment).
PLUM HOLD 02/18/2010 02/18/2010
Note: Held By: FREODICA 1. Men's and women's toilet dimensions for handicap do not meet code. Please see FBC 2007 Figure 30e. 2. Plan and elevation dimensions do not match each other. 3. Domestic water distribution pipe size appears to be smaller than what is required. Provide calculations.
FI1 HOLD 02/18/2010 02/22/2010
Note: Held By: JPATTEE Did not address previous comments.
ELEC HOLD 02/17/2010 02/17/2010
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit #2009120287 (Palm Coast Little League @ 5455 Belle Terre Pkwy.) 2/17/2010 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Coordinate voltage of service. Riser shows 240V 1PH, panel schedule shows 208V 3PH. Confirm feeders. 2. Clarify service disconnecting means including size (amperage) and voltage. 3. Revise riser to show quantity and size of conductors between meter and first means of disconnect. 4. Revise load calculation to include all equipment and motor loads, i.e. water heater, well pump, garage door opener, and refrigerator. 5. Clarify 5HP load in load calculation and revise load per nameplate or NEC Table 430.248. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD HOLD 02/17/2010 02/18/2010
Note: Held By: JJOSEPH 1.Provide Florida Product Approval number for all doors and windows. 2. Provide classication type of construction, occupancy and occupant load . 3 Provide column footing and footer details
UD1 COMPLETE 01/13/2010 01/15/2010
Note: Released By: CJOHNSON
FI1 HOLD 12/29/2009 01/05/2010
Note: Held By: JPATTEE 1) Door labeled #3 for storage room, reverse swing or swing in. 2) K fire extinguisher not required unless cooking produces grease laden vapors.
MECH HOLD 12/28/2009 12/28/2009
Note: Held By: FREODICA 1. Provide energy calculations. 2. Provide complete duct sizes for supply and return ducts. 3. Indicate distributed CFM by supply diffusers and return grilles. 4. Provide required outdoor ventilation air per FMC 2007 Table 403.3. 5. Provide exhaust for restrooms and exhaust fan specifications. 6. Provide ductwork material specifications. 7. Provide HVAC details such as AHU mounting, duct supports, condensate disposal etc.
PLUM HOLD 12/28/2009 12/28/2009
Note: Held By: FREODICA 1. Provide complete pipe sizes of sanitary, domestic water and vent lines on plumbing riser diagram. 2. Provide location of drinking fountain and show it on plumbing riser. 3. Provide service sink in Plumbing Fixture Schedule, its location on plan and in riser diagram. 4. Single compartment sink (Sink-2) shown on Plumbing Fixture Schedule is not shown on plan or riser diagram. Please clarify. 5. Water closets shown on plan are all designated as WC-1 but are not shown on Plumbing Fixture Schedule. They are shown as WC-H. Please clarify. 6. Floor drains are noted on plan but are not shown on plan or riser diagram. Please clarify. 7. Provide material specifications for DWV and domestic water (hot & cold).
BLD HOLD 12/23/2009 12/28/2009
Note: Held By: JJOSEPH 1.Provide Florida Product Approval number for all doors and windows. 2. Provide wall storage details separating the meeting Hall .(UL Number) 3. Provide classication type of construction. 4. Provide column footing and footer details 5. The door between rooms 106 and 107 needs to be 20 minutes fire rated door. 6. The ceiling room 106 cannot be accoustical LAY-in tile. Revise and make correction.
ELEC HOLD 12/23/2009 12/23/2009
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009120287 (Palm Coast Little League Meeting/Storage Bldg. @ 5455 Belle Terre Pkwy.) 12/23/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide circuit loads for all panel circuits. 2. Provide electrical riser diagram including feeder conductor and conduit sizes, OCP size, overhead or underground. Show location of meter and utility transformer on plans. 3. Provide Service Demand Load Calculation per FBC 106.3.5 Electrical #7 and NEC 220 Part III. 4. Provide emergency/exit lighting in Equipment Storage room. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
ZON COMPLETE 12/23/2009 12/23/2009
Note: Released By: ECOYNE correction - site plans & Development order
ZON HOLD 12/14/2009 12/14/2009
Note: Held By: ECOYNE provide approved site plan and development order faxed 12/14/09 3:12pm

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/10/2012
REINSPECTION FEE ¤40.00 05/10/2012
REINSPECTION FEE ¤40.00 05/10/2012
REINSPECTION FEE ¤40.00 05/10/2012
REINSPECTION FEE ¤40.00 05/10/2012
REINSPECTION FEE ¤40.00 05/10/2012
REVISION ¤40.00 05/10/2012
REVISION ¤40.00 05/10/2012
REVISION ¤40.00 05/10/2012
DUMMY FEE ¤1.00 05/25/2010
Fees Total Due: ¤0.00 Total Paid: ¤361.00