Permit #2009120356
Permit Details
Status: VOID
| Parcel Id: 14-11-30-5540-00000-00B0 |
| Block: 00000 |
| Subdivision: 1188 - ST JOE PLAZA AT PC |
| Job Phone: (386) 547-0409 |
| Location Address: 235 ST JOE PLAZA DR SW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| NOC: Unknown |
| Applicant name: BOHDAN HAWRYLUK |
| Owner: ST JOE PLAZA INC |
|
Address 76-36 265TH ST NEW HYDE PARK, NY 11040 |
| Lot: 00B0 |
| Contracted Stated Job Value: ¤1,200.00 |
| Job Description: # 235 - 2X4 TILE INTO CEILING/PLUMBING BOILER TO WATER SUPPLY AND ELECTRICAL BROUGHT TO CODE. |
| Type: CN |
Contractor
INTERCOASTAL CONSTRUCTION CO.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
14 SLIPPER ORCHID TRAIL EAST PALM COAST, FL 32164 |
CBC035048 (Exp: 08/31/2024) | (386) 547-0409 | 386-673-8868 |
Sub Contractors
HAROLD C WINTZ
| Status | Location Address | State License Number | Phone |
| CANCEL |
1721 Palm Road Ormond Beach, FL 32174 |
EC13001342 (Exp: 08/31/2018) | (386) 212-4786 |
AARON JOSHUA CRANDALL
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1519 SOUTH DAYTONA AVE PALM COAST, FL 32164 |
CFC1425974 (Exp: 08/31/2026) | 386-931-6329 |
Inspection History
| Type | Request Date | Result | Inspector |
| ABOVE CEILING | |||
| 2ND ROUGH ELECTRICAL | |||
| COMMERCIAL POWER INSPECTION | |||
| ELECTRICAL FINAL | |||
| COMMERCIAL BUILDING FINAL | |||
| UTILITY COMMERCIAL FINAL | |||
| UTILITY COMPANY FINAL | |||
| FIRE FINAL |
Review History
| Department | Status | Date In | Date Out |
| UD1 | COMPLETE | 12/23/2009 | 12/28/2009 |
| Note: Released By: CJOHNSON | |||
| ZON | COMPLETE | 12/17/2009 | 12/17/2009 |
| Note: Released By: ECOYNE interior work only | |||
| ELEC | HOLD | 12/17/2009 | 12/17/2009 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application#2009120356 (Dry Cleaning Equipment Installation @ Unit 235 St. Joe Plaza Palm Coast Pkwy.) 12/17/2009 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide legible electrical specifications/requirements (voltage, load, circuit/panel identification, wire size) for the following equipment per FBC Building 106.1.1 and NEC 110: a. Gas-fired steam boiler b. Induced draft fan for gas-fired steam boiler c. Air compressor d. 80 LB Washer e. Pants Leg Press f. Pants Topper g. Utility Press h. Shirt Unit i. Collar and Cuff Units j. Hot Head Press 2. Identify size, voltage and location of required disconnects for gas-fired steam boiler and other equipment as required by NEC 422. 3. Provide electrical riser diagram with all OCP, panels and feeders shown per FBC Building 106.3.5. 4. Provide load calculations for all revised panels and service per FBC Building 106.3.5. 5. Identify panel/s location on plan sheet per NEC 110. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| PLUM | COMPLETE | 12/17/2009 | 12/17/2009 |
| Note: Released By: JMCGOWEN | |||
| ELEC | CANCEL |