I want to search for...
Permit #2010020324
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-1090-00000-00B0 |
| Total Square Footage: 2300 sqft |
| Block: 00000 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: (386) 547-0409 |
| Location Address: 160 CYPRESS POINT PKWY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| NOC: Unknown |
| Applicant name: BOHDAN HAWRYLUK |
| Owner: ASNACO LLC |
|
Address PO BOX 953966 LAKE MARY, FL 32795 |
| Lot: 00B0 |
| Contracted Stated Job Value: ¤2,000.00 |
| Job Description: BLDG A 114 INSTALL OFFICE PARTITIONS- MOVE GRID DROP IN LIGHTING |
| Type: CN |
Contractor
INTERCOASTAL CONSTRUCTION CO.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
14 SLIPPER ORCHID TRAIL EAST PALM COAST, FL 32164 |
CBC035048 (Exp: 08/31/2024) | (386) 547-0409 | 386-673-8868 |
Sub Contractors
HAROLD C WINTZ
| Status | Location Address | State License Number | Phone |
| CANCEL |
1721 Palm Road Ormond Beach, FL 32174 |
EC13001342 (Exp: 08/31/2018) | (386) 212-4786 |
Inspection History
| Type | Request Date | Result | Inspector |
| FRAMING | |||
| ABOVE CEILING | |||
| 2ND ROUGH ELECTRICAL | |||
| COMMERCIAL POWER INSPECTION | |||
| ELECTRICAL FINAL | |||
| COMMERCIAL BUILDING FINAL | |||
| UTILITY COMMERCIAL FINAL | |||
| UTILITY COMPANY FINAL | |||
| FIRE FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/05/2010 | 03/05/2010 |
| Note: Released By: JJOSEPH | |||
| ELEC | COMPLETE | 03/02/2010 | 03/02/2010 |
| Note: Released By: SKNOPF Approved for Release. | |||
| BLD | HOLD | 03/02/2010 | 03/02/2010 |
| Note: Held By: JJOSEPH 1. According to FBC 2007 at ADA Section page 11.50 figure 5 the leg space must be greater or equal than 20" ( he cannot be 18"). 2. The UL # P522 provided is not correct for the fire wall rated; please revise and make correction. corrections submitted | |||
| ELEC | HOLD | 02/18/2010 | 02/18/2010 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit #2010020324 (Commercial Interior Alteration @ Unit A-114 160 Cypress Point Pkwy.) 2/18/2010 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. Provide circuitry for revised lighting plan. 2. Provide panel schedule. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | HOLD | 02/17/2010 | 02/18/2010 |
| Note: Held By: JMCGOWEN 1) add description of ada counters measurements 2)seperation fo 1st and second floor fire 1hr wall see detail on plan & wall sections 3) provide no new lighting on plan 4) provide door & hardware schedule the foward reach as per ADA figure 5 calls for 20" min. please revise provide UL test numbers for fire seperation walls | |||
| UD1 | COMPLETE | 02/16/2010 | 02/17/2010 |
| Note: Released By: CJOHNSON | |||
| ELEC | HOLD | 02/15/2010 | 02/15/2010 |
| Note: Held By: JMCGOWEN provide load calculation to include added lighting fixtures, provide new emergency light and exit light locations | |||
| FI1 | COMPLETE | 02/15/2010 | 02/16/2010 |
| Note: Released By: JPATTEE Relocate emergency light in office to hall wall. | |||
| ZON | HOLD | 02/12/2010 | 02/12/2010 |
| Note: Held By: ECOYNE plans include 3' vinyl fence provide confirmation if fence a part of this interior alteration 2/12/10 ecoyne 9:16am spoke with contractor | |||
| ZON | COMPLETE | 02/12/2010 | 02/12/2010 |
| Note: Released By: ECOYNE | |||
| BLD | HOLD | 02/12/2010 | 02/15/2010 |
| Note: Held By: JMCGOWEN provide detailed ADA accessible counter as per chapter 11 FBC provide door and hardware schedule. The stair well was originally built unprotected because both the first and second floor units were to be combined , provide detail for fire separation between up stairs and down stairs units. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | |
| BUILDING CODE ADMIN FUND | ¤11.50 | |
| BUILDING DISCOUNT 100% | (¤244.08) | |
| ELECTRIC FEE | ¤61.20 | |
| FIRE PLANS REVIEW | ¤25.00 | |
| PERMIT FEE | ¤50.00 | |
| PLAN CHECK FEE | ¤100.00 | |
| RADON FEE | ¤11.50 | |
| REVISION | ¤40.00 | |
| SITE PLAN 20 | ¤20.00 | |
| Fees | Total Due: ¤135.12 | Total Paid: ¤0.00 |