I want to search for...
Permit #2010050461
Permit Details
Status: COED
| Parcel Id: 07-11-31-7031-00210-0010 |
| CONDITIONED SPACE: 1514 sqft |
| CONDITIONED SPACE: 991 sqft |
| OPENED PORCH (WITH ROOF) : 252 sqft |
| GARAGE: 498 sqft |
| Total Square Footage: 3255 sqft |
| Block: 00210 |
| Subdivision: 2166 - SECTION 31-ROYAL PALMS |
| Job Phone: 386-672-6101 |
| Location Address: 18 RIPTIDE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/01/2010 |
| NOC: RECORDED |
| Applicant name: JOHN DAVID MINABERRY |
| Owner: ALMEIDA MARLENE & JULIO VASQUEZ JTWROS |
|
Address 5550 E MICHIGAN ST #3207 ORLANDO, FL 32822 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤2,000,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KEYSTONE HOMES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1339 W GRANADA BLVD ORMOND, FL 32174 |
CRC1329222 (Exp: 08/31/2026) | 386-672-6101 | 386-672-6102 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 11/18/2010 | FINAL APPROVED | RMARVEL |
| STORMWATER FINAL INSPECTION | 11/16/2010 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY | 11/15/2010 | APPROVED | JJOSEPH |
| UTILITY COMPANY FINAL | 11/15/2010 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 11/15/2010 | Disapproved -FEE REQUIRED | CMINI |
| Note: 5/27/10 no existing swale or raod damage/gl/la 6/8/10 left message in job box, need to bury silt fence 4" to 6" into ground and back fill downward side of fence 6/18/10 everything ok//dr Inspection Resulted at 11/15/2010 3:32:07 PM NEED TO HAVE FINAL SURVEY ON SITE. | |||
| RESIDENTIAL EARLY POWER | 10/21/2010 | APPROVED | RMARVEL |
| Note: requested by contractor Inspection Resulted at 10/21/2010 2:41:02 PM PALMETTO | |||
| RESIDENTIAL EARLY POWER | 10/20/2010 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 10/20/2010 3:29:47 PM THE CONDUIT AT THE ELECTRICAL SERVICE PANEL HAS BEEN PULLED OFF THE WALL. 2ND TRIP | |||
| RESIDENTIAL EARLY POWER | 10/19/2010 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 10/19/2010 11:06:41 AM THE CONDUIT AT THE ELECTRICAL SERVICE PANEL HAS BEEN PULLED OFF THE WALL. | |||
| PRE DRIVEWAY | 09/28/2010 | APPROVED | BCHAMBERLAIN |
| INSULATION INSPECTION | 08/31/2010 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 08/30/2010 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 8/30/2010 12:30:25 PM NEED TO FIRECAULK OR FIREFOAM ALL ANNULAR AND OPENINGS...NEED APPROVED NAIL PLATE AT DRYER VENT. | |||
| ALL ROUGH | 08/24/2010 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/24/2010 12:45:06 PM APPROVED NAIL PLATE AT DRYER DUCT/STRAP DRYER DUCT MID-POINT SAME ROOM/NAIL PLATE AT LOW-VOLT WIRING-CHECK AT NEXT INSPECTION | |||
| ALL ROUGH | 08/19/2010 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 8/19/2010 2:46:19 PM HVAC DUCT PLAN IS MISSING. THE EXPOSED WIRES ABOVE THE ELECTRIC PANEL NEED TO BE PROTECTED. THE KITCHEN AND BONUS ROOM LIGHTING IS NOT PER PLAN. THE PLUMBING DRAIN,WASTE AND VENT SYSTEM NEEDS TO HAVE TEST PRESSURE ON IT. | |||
| LATH /BRICK FLASHING | 08/09/2010 | APPROVED | CMINI |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/29/2010 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/27/2010 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 7/27/2010 2:56:20 PM TIGHTEN ALLTHREAD. ALLTHREAD MISSING IN LOCATIONS. RECHECK PER PLANS. MISSING ENGINEERING ON TRUSS 18. MULTIPLE SHINERS. SHOW PAPER WORK FOR ZIP BOARD THAT ALLOWS NO CLIPS BETWEEN TRUSSES. | |||
| LINTEL | 06/28/2010 | APPROVED | JHINDMAN |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/24/2010 | APPROVED | LAPTEKAR |
| FOUNDATION SURVEY APPROVED BY ZONING | 06/24/2010 | APPROVED | BBARTON |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/21/2010 | APPROVED | JHINDMAN |
| FIRST ROUGH PLUMBING INSPECTION | 06/17/2010 | APPROVED | JHINDMAN |
| Note: per request from robby | |||
| TEMPORARY POLE | 06/17/2010 | APPROVED | JHINDMAN |
| Note: per request from Robby Inspection Resulted at 6/17/2010 2:44:19 PM CALLED FPL ON 6-17-10 AT 3:45 P.M. | |||
| STORMWATER EROSION CONTROL | 06/11/2010 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| STEM WALL FOUNDATION | 06/11/2010 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/09/2010 | APPROVED | JHINDMAN |
| Note: Robbie called to schedule this inspection Inspection Resulted at 6/9/2010 3:09:28 PM THE STEMWALL FOOTING IS OK. | |||
| STORMWATER EROSION CONTROL | 06/08/2010 | Disapproved - NO FEE | DRANDALL |
| Note: left notice....need to bury silt fence 4" to 6" into ground and back fill back side of fence |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 11/15/2010 | 11/15/2010 |
| Note: Held By: JJOSEPH Revise the final survey to match it to the original site plan submitted. FINAL SURVEY | |||
| SW1 | COMPLETE | 11/10/2010 | 11/15/2010 |
| Note: Released By: JJOSEPH FINAL SURVEY | |||
| BLD | COMPLETE | 08/23/2010 | 08/23/2010 |
| Note: Released By: LHITES REVISION- light fixture changes called contractor 3:32 pm | |||
| BLD | COMPLETE | 07/29/2010 | 07/29/2010 |
| Note: Released By: LHITES roof & wall sheating materials changed | |||
| BLD | COMPLETE | 07/23/2010 | 07/23/2010 |
| Note: Released By: JMCGOWEN correction to the revision - truss corrections | |||
| BLD | HOLD | 07/21/2010 | 07/21/2010 |
| Note: Held By: JMCGOWEN New truss layout truss modifications and repairs will need to be designed by the truss manufactures engineer. provide proper signed and sealed drawings | |||
| MECH | COMPLETE | 05/28/2010 | 05/28/2010 |
| Note: Released By: JMCGOWEN revision- duct layout & duct size | |||
| BLD | COMPLETE | 05/28/2010 | 05/28/2010 |
| Note: Released By: JMCGOWEN | |||
| BLD | HOLD | 05/26/2010 | 05/26/2010 |
| Note: Held By: JMCGOWEN provide a florida registered engineer to seal structural pages of plan | |||
| MECH | HOLD | 05/26/2010 | 05/26/2010 |
| Note: Held By: JMCGOWEN duct layout provide duct sizes | |||
| ELEC | COMPLETE | 05/26/2010 | 05/26/2010 |
| Note: Released By: JMCGOWEN electrical load calcs & pep tank outlet | |||
| BLD | HOLD | 05/24/2010 | 05/24/2010 |
| Note: Held By: JMCGOWEN provide an other truss package, two complete | |||
| ELEC | HOLD | 05/24/2010 | 05/24/2010 |
| Note: Held By: JMCGOWEN provide pep tank j-box location. provide a revised load calculation to include 20 amp pep tank circuit. | |||
| MECH | HOLD | 05/24/2010 | 05/24/2010 |
| Note: Held By: JMCGOWEN provide duct layout {supply, return, and transfer grills, size and location} | |||
| PLUM | COMPLETE | 05/24/2010 | 05/24/2010 |
| Note: Released By: JMCGOWEN | |||
| ZON | COMPLETE | 05/21/2010 | 05/21/2010 |
| Note: Released By: BBARTON | |||
| SW1 | COMPLETE | 05/19/2010 | 05/19/2010 |
| Note: Released By: LAPTEKAR Received upgraded survey and grading plan///erosion control measures will be required//la | |||
| SW1 | HOLD | 05/14/2010 | 05/14/2010 |
| Note: Held By: LAPTEKAR 1. topographic survey missing the road centerline elevation. 2. Grading plan missing grade elevation proposals of property line, rear yard and side yard between property line and structure. Majority of drainage should be directed to the front swale as possible...with as little drainage directed to the adjacent ditch. 5/14/10 emailed comments | |||
| ZON | HOLD | 05/14/2010 | 05/17/2010 |
| Note: Held By: BBARTON 1. Show the AC pad on site plans, submit new site plans showing AC pad. 2. Site plans need to indicate if there are or are not any index trees on the lot, submit a new site plan indicating index trees. 3. The submitted landscape plan is incomplete. Submit new landscaping plans showing the following: (a) Indicate the tree types, caliper (measured above grade) and height. (b) There are bare spots in the front of the residence where landscaping is required. Show the required landscaping along the left side of the driveway parallel to the walkway and wrapping the right corner of the house. (c) Front landscaping needs to have a variety of shrubbery with varying heights. Provide a new landscape plan that indicates more that one shrub being used for the required front landscaping. (d) Show the AC pad with the required landscaping (min of 24"-30" in height). 4. Site plans are missing the walkway and driveway width. Submit new site plans indicating widths. 5. The submitted site plans and the site plan in the construction drawings do not match. The porch sizes are different, indicate the correct porch size and revise plans an/or site plans to match. 6. The wooden deck indicated on the construction plans are not shown of the site plans, show deck on site plans with dimensions and setbacks. faxed and emailed hold comments to contractor 05/17/10 @ 10:54 am | |||
| ZON | COMPLETE | 11/15/2010 | |
| Note: Released By: JJOSEPH |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 11/19/2010 |
| REINSPECTION FEE | ¤40.00 | 11/19/2010 |
| REINSPECTION FEE | ¤40.00 | 11/19/2010 |
| REINSPECTION FEE | ¤40.00 | 11/19/2010 |
| REINSPECTION FEE | ¤40.00 | 11/19/2010 |
| REINSPECTION FEE | ¤40.00 | 11/19/2010 |
| REVISION | ¤40.00 | 11/19/2010 |
| REVISION | ¤40.00 | 07/29/2010 |
| REINSPECTION FEE | ¤40.00 | 07/29/2010 |
| REVISION | ¤40.00 | 07/26/2010 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/01/2010 |
| SITE PLAN 20 | ¤20.00 | 06/01/2010 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/01/2010 |
| TRANS IMPACT FEE 7-RESIDENTIAL | ¤3,565.34 | 06/01/2010 |
| NEW RESIDENTIAL INSPECTIONS | ¤548.00 | 06/01/2010 |
| BUILDING CODE ADMIN FUND | ¤16.28 | 06/01/2010 |
| BUILDING DISCOUNT 100% | (¤1,215.72) | 06/01/2010 |
| ELECTRIC FEE | ¤224.40 | 06/01/2010 |
| FIRE IMPACT FEE RES 4/1/10 | ¤195.62 | 06/01/2010 |
| MECHANICAL FEE | ¤224.40 | 06/01/2010 |
| PERMIT FEE | ¤20.00 | 06/01/2010 |
| PARKS IMPACT FEE 4/01/10 | ¤1,264.06 | 06/01/2010 |
| PLAN CHECK FEE | ¤109.60 | 06/01/2010 |
| PLUMBING FEE | ¤224.40 | 06/01/2010 |
| RADON FEE | ¤16.28 | 06/01/2010 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,292.66 |