I want to search for...

Permit #2010050791

Permit Details

Status: COED

Parcel Id: 07-11-31-7012-00120-0010
CONDITIONED SPACE: 1512 sqft
GARAGE: 496 sqft
OPENED PORCH (WITH ROOF) : 56 sqft
Total Square Footage: 2064 sqft
Block: 00120
Subdivision: 2187 - SECTION 12-BELLE TERRE
Job Phone: 386-672-6101
Location Address: 1 BALLARD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/11/2010
NOC: RECORDED
Applicant name: JOHN DAVID MINABERRY
Owner: ASCIONE, RALPH & THERESA

Address

300 SEA ISLAND RD

JESSUP, GA 31545

Lot: 0010
Contracted Stated Job Value: ¤130,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

KEYSTONE HOMES
Status Location Address State License Number Phone Fax
ACTIVE

1339 W GRANADA BLVD

ORMOND, FL 32174

CRC1329222 (Exp: 08/31/2026) 386-672-6101 386-672-6102

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 10/27/2010 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION 10/27/10 (JB) APPROVED LANDSCAPING.
FINAL COMPLETE BUILDING INSPECTION 10/26/2010 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 10/26/2010 3:10:31 PM INSULATION CERT/WATER HAMMER AT DISHWASHER
UTILITY COMPANY FINAL 10/25/2010 APPROVED MBACON
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 10/22/2010 APPROVED - AS NOTED BCHAMBERLAIN
Note: 6/14/10 no swale or road damage/DR/ REQUESTED BY CONTRACTOR 10/22/10 Stmwtr fnl approved as noted: clean out culvert ends, remove silt fence and portable toilet.
FINAL SURVEY 10/22/2010 APPROVED JJOSEPH
UTILITY COMPANY FINAL 10/22/2010 Disapproved - NO FEE TSCHWEERS
Note: can't locate sewer cleanout near right of way. needs to be uncovered so it can inspected.
RESIDENTIAL EARLY POWER 10/14/2010 APPROVED RMARVEL
Note: Inspection Resulted at 10/14/2010 1:25:00 PM PALMETTO
PRE DRIVEWAY 09/16/2010 APPROVED BCHAMBERLAIN
Note: THIS IS A REINSPECTION requested by contractor
PRE DRIVEWAY 09/15/2010 CANCELLED BY APPLICANT BCHAMBERLAIN
INSULATION INSPECTION 08/06/2010 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION per request from Trishia
INSULATION INSPECTION 08/05/2010 Disapproved -FEE REQUIRED CMINI
Note: Trisha from Keystone Homes called to schedule this inspection Inspection Resulted at 8/5/2010 3:10:25 PM NEED TO PROVIDE ENERGY CALCULATGIONS FOR INSPECTION.
ALL ROUGH 07/30/2010 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 7/30/2010 12:51:32 PM FRAME AT ELECTRIC PANEL/16 GUAGE STRAPPING AT ALL OVER-NOTCHED TOP PLATES
LATH /BRICK FLASHING 07/29/2010 APPROVED CMINI
Note: THIS IS A REINSPECTION
TEMPORARY POLE 07/26/2010 APPROVED CMINI
Note: Inspection Resulted at 7/26/2010 12:55:34 PM CALLED DAWN FROM FPL AT 10:46 AM....PALMETTO ELECTRIC
LATH /BRICK FLASHING 07/23/2010 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 7/23/2010 1:14:17 PM LATH TO BE FASTENED TO FRAMING MEMBERS ONLY(TOP CORD,BOTTOM CORD AND UPRIGHTS) A MINIMUM OF 7IN ON CENTER.NAILS MUST PENETRATE FRAMING MEMBERS 3/4 IN MINIMUM/NO NAILS IN THE FIELD AT ALL. BACK OUT NAILS IN FIELD.SEE SHEET I LEFT FOR FUTURE REFERENCE.BEEN IN FORCE FOR OVER A YEAR.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/22/2010 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/19/2010 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 7/19/2010 3:11:03 PM NEED TO HAVE X-BRACING FOR GABLE END.....NEED TO BLOCK JOINTS FOR OSB LAID HORIZONTALY PER MANUFACTURES SPECS...NEED TO SHIM AND OR GROUT UNDER TRUSSES THAT ARE NOT SITTING FULL BEARING ON BLOCK MOSTLY AT FRONT AND LEFT OF HOUSE...LOOSE SHEETS AT FRONT ENTRANCE...
LINTEL 07/02/2010 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LINTEL 07/01/2010 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection added by LW per phone call from contractor.Vent not properly attached in masonary wall
FOUNDATION SURVEY APPROVED BY STORMWATER 07/01/2010 APPROVED LAPTEKAR
FOUNDATION SURVEY APPROVED BY ZONING 07/01/2010 APPROVED BBARTON
MONOLITHIC SLAB INSPECTION/SLAB 06/25/2010 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 06/23/2010 APPROVED RMARVEL

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/22/2010 10/22/2010
Note: Released By: JJOSEPH Revised final survey
SW1 HOLD 10/21/2010 10/21/2010
Note: Held By: JJOSEPH Need to show Elevations on all adjacent identified (e.g vacant and improved lots) properties l at a minimum of 20 foot interval ,on a 10 foot offset outside the properties line. Faxed and emailed on 10/21/10 at 2:44PM
ZON COMPLETE 06/10/2010 06/10/2010
Note: Released By: ECOYNE CORRECTION BONDING PLANTINGS TREE SIZE
BLD COMPLETE 06/10/2010 06/10/2010
Note: Released By: JMCGOWEN LOAD CALC CONDUCTOR SIZES SERVICE ENTERANCE GROUNDING SMOKE DETECTORS CARBON MONOXIDE VENT FOR BATH TUB & SHOWER ENGINEER SEAL DOOR & WINDOW ENGINEERING HANGAR STRAP SCHEDULE
PLUM COMPLETE 06/10/2010 06/10/2010
Note: Released By: JMCGOWEN
ELEC COMPLETE 06/10/2010 06/10/2010
Note: Released By: JMCGOWEN
SW1 COMPLETE 06/01/2010 06/02/2010
Note: Released By: LAPTEKAR received grading plan//checked with MB
SW1 HOLD 05/27/2010 05/27/2010
Note: Held By: JMCGOWEN provide an florida registered engineer to sign and seal structural pages of plans, provide florida produce approvals for all windows and doors,provide site specific hanger and strap schedule,
ELEC HOLD 05/27/2010 05/27/2010
Note: Held By: JMCGOWEN provide load calculation, provide conductor sizes [service entrance, grounding], provide panel location, provide smoke detecter and carbon monoxide detecter locations
MECH COMPLETE 05/27/2010 05/27/2010
Note: Released By: JMCGOWEN
PLUM HOLD 05/27/2010 05/27/2010
Note: Held By: JMCGOWEN provide vent for bath tub and vent for shower
SW1 HOLD 05/26/2010 05/26/2010
Note: Held By: LAPTEKAR 1.Grading plan has flow arrows only...need grading plan to show proposed grade elevations next to existing elevations of and swale and culvert elevation proposals.. 5/26/10 emailed comments
ZON HOLD 05/26/2010 05/26/2010
Note: Held By: ECOYNE provide height of trees (new and to remain on lot) provide banding around windows/doors on home facing Barrington Drive 3 gallon plantings required on left elevation facing Barrington Drive (wrap around rear left elevation) faxed 05/26/10 3:55pm

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 10/28/2010
REINSPECTION FEE ¤40.00 10/28/2010
REINSPECTION FEE ¤40.00 10/28/2010
REINSPECTION FEE ¤40.00 10/28/2010
REINSPECTION FEE ¤40.00 10/28/2010
REINSPECTION FEE ¤40.00 10/28/2010
NEW RESIDENTIAL INSPECTIONS ¤338.00 06/11/2010
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 06/11/2010
SITE PLAN 20 ¤20.00 06/11/2010
STORM WATER PERMIT FEES ¤80.00 06/11/2010
TRANS IMPACT FEE 7-RESIDENTIAL ¤3,565.34 06/11/2010
FIRE IMPACT FEE RES 4/1/10 ¤195.62 06/11/2010
MECHANICAL FEE ¤161.40 06/11/2010
PERMIT FEE ¤20.00 06/11/2010
PARKS IMPACT FEE 4/01/10 ¤1,264.06 06/11/2010
PLAN CHECK FEE ¤67.60 06/11/2010
PLUMBING FEE ¤161.40 06/11/2010
RADON FEE ¤10.32 06/11/2010
BUILDING CODE ADMIN FUND ¤10.32 06/11/2010
BUILDING DISCOUNT 100% (¤818.82) 06/11/2010
ELECTRIC FEE ¤161.40 06/11/2010
Fees Total Due: ¤0.00 Total Paid: ¤9,076.64