I want to search for...
Permit #2010060944
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-00300-0050 |
| Total Square Footage: 986 sqft |
| Block: 00300 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: (386)566-5274 |
| Location Address: 1 EAST PL |
| Type: PO - POOL |
| Issue Date: 07/06/2010 |
| NOC: RECORDED |
| Applicant name: RALPH T LEE JR |
| Owner: CRAWFORD EARNEST E SR |
|
Address 1 EAST PLACE PALM COAST, FL 32164 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤20,000.00 |
| Job Description: CONSTRUCTION OF SWIMMING POOL W/EXISTING FENCE |
| Type: CN |
Contractor
AQUATIC DESIGN SYSTEMS INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
2090 S. NOVA RD SOUTH DAYTONA, FL 32119 |
UNIT AA 01 BOX 13 SOUTH DAYTONA, FL 32119 |
CPC1457500 (Exp: 08/31/2016) | (386)566-5274 | (386)767-3523 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL - FINAL | 09/16/2010 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION requested by contractor | |||
| STORMWATER FINAL INSPECTION | 09/10/2010 | APPROVED | JHINDMAN |
| Note: 7/21/2010 on property swale damage, everything else ok//dr requested by contractor | |||
| POOL - FINAL | 09/10/2010 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: requested by contractor Inspection Resulted at 9/10/2010 3:06:49 PM YOU NEED TO HAVE THE VACUUM GAUGE ON THE PUMP MOTOR TO CHECK THE TDH PRESSURE. | |||
| UTILITY COMPANY FINAL | 09/10/2010 | APPROVED | TSCHWEERS |
| Note: requested by contractor | |||
| FINAL SURVEY | 09/09/2010 | APPROVED | JJOSEPH |
| ELEC & ALARM | 09/08/2010 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FOUNDATION SURVEY APPROVED BY ZONING | 09/08/2010 | APPROVED | CBENTLEY |
| ELEC & ALARM | 09/01/2010 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 9/1/2010 12:44:45 PM POOL ALARMS MUST MEET THE FOLLOWING.THE ALARM MUST COMPLY WITH UL 2017, HAVE A MINIMUM SOUND PRESSURE RATING OG 85 DB A AT 10 FEET.THE EXIT ALARM SHALL PRODUCE A CONTINUOUS AUDIBLE WARNING WHEN THE DOOR IS OPENED. THE ALARM CAN HAVE A DEACTIVATION SWITCH THAT CAN SHUT OFF THE ALARM FOR NO MORE THAN 15 SECONDS. | |||
| POOL DECK INSPECTION | 07/22/2010 | APPROVED | JHINDMAN |
| Note: Ralph called to schedule this inspection | |||
| STEEL & GROUND | 07/08/2010 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 09/07/2010 | 09/08/2010 |
| Note: Released By: CBENTLEY foundation survey | |||
| SW1 | COMPLETE | 09/07/2010 | 09/07/2010 |
| Note: Released By: JJOSEPH final survey | |||
| SW1 | COMPLETE | 07/06/2010 | 07/06/2010 |
| Note: Released By: WKINELL Came in with new survey/LGP.\\wk | |||
| ZON | COMPLETE | 06/29/2010 | 06/29/2010 |
| Note: Released By: BBARTON | |||
| BLD | COMPLETE | 06/29/2010 | 06/29/2010 |
| Note: Released By: FREODICA Approved for release per J. McGowen. | |||
| SW1 | HOLD | 06/29/2010 | 06/29/2010 |
| Note: Held By: LAPTEKAR Missing current sealed topographic survey (less than a year old) referencing 1988 NAVD datum and a lot grading plan with proposed grades to comply with Stormwater requirements effective Nov. 1, 2007. 6/29/10 emailed comments | |||
| ZON | HOLD | 06/28/2010 | 06/28/2010 |
| Note: Held By: BBARTON 1. Accurately show the location of the fence on the site plans. 2. Site plans are missing the pool deck dimensions. 3. Write the equipment pad dimensions on site plan to ensure the equipment pad does not encroach into the 5' utility easement. 4. The numbers on the pool plan do not add up to the deck dimensions provided on the pool plan. Revise to match. 5. Rear setback is incorrect. faxed and emailed hold comments to contractor 06/28/10 @ 4:21 pm |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/13/2010 |
| REINSPECTION FEE | ¤40.00 | 09/07/2010 |
| SITE PLAN 20 | ¤20.00 | 07/06/2010 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/06/2010 |
| BUILDING DISCOUNT 100% | (¤198.00) | 07/06/2010 |
| PERMIT FEE | ¤180.00 | 07/06/2010 |
| PLAN CHECK FEE | ¤40.00 | 07/06/2010 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤202.00 |