I want to search for...
Permit #2010090838
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-000G0-0210 |
| COMMERCIAL SQUARE FOOTAGE: 11831 sqft |
| Total Square Footage: 11831 sqft |
| Block: 000G0 |
| Subdivision: - |
| Job Phone: 386-338-7785 |
| Location Address: 85 CYPRESS POINT PKWY |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 12/17/2010 |
| NOC: RECORDED |
| Applicant name: THOMAS M SCAGLIONE |
| Owner: INTERNATIONAL CARPET OF FLORIDA LLC |
|
Address 109 S. SIXTH ST FLAGLER BEACH, FL 32136 |
| Lot: 0210 |
| Contracted Stated Job Value: ¤500,000.00 |
| Job Description: (NIKZAD PLAZA) RETAIL SHOPS SITE & BLDG SHELL |
| Type: CN |
Contractor
T-CON GROUP, INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
3246 NORTH POWERLINE ROAD POMPANO BEACH, FL 33069 |
CBC1251999 (Exp: 08/31/2020) | 954-825-8369 |
Sub Contractors
ISAAC WALTER JOHNSTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
887 BRENTWOOD DRIVE Daytona Beach, FL 32117 |
CFC023634 (Exp: 08/31/2026) | (386) 252-7047 |
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
Inspection History
| Type | Request Date | Result | Inspector |
| COMMERCIAL BUILDING FINAL | 11/28/2011 | FINAL APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL BUILDING FINAL | 11/21/2011 | Disapproved - NO FEE | CMINI |
| Note: Inspection Resulted at 11/21/2011 3:21:43 PM BUILDING SHELL OK..WAITING FOR OUTSTANDING INSPECTIONS AND PAPERWORK ON SITE PERMIT. | |||
| UTILITY COMMERCIAL FINAL | 11/17/2011 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 11/17/2011 | APPROVED | KKING |
| ELECTRICAL FINAL | 10/04/2011 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 10/04/2011 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 09/06/2011 | Disapproved -FEE REQUIRED | LHITES |
| Note: Inspection Resulted at 9/6/2011 11:21:59 AM NEED EXIT SIGN OVER REAR DOOR IN STORAGE AREA | |||
| ELECTRICAL FINAL | 09/06/2011 | Disapproved - NO FEE | LHITES |
| Note: Inspection Resulted at 9/6/2011 11:22:00 AM FEE ON FIRE FINAL. NEED EXIT SIGN INSTALLED | |||
| PLUMBING FINAL | 09/06/2011 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 9/6/2011 2:54:27 PM PLUMBING ROUGHED IN FOR FUTURE | |||
| FOUNDATION SURVEY APPROVED BY ZONING | 09/02/2011 | APPROVED | DRAMIREZ |
| 2ND ROUGH ELECTRICAL | 08/05/2011 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| FIREWALL FINAL INSPECTION | 08/05/2011 | APPROVED | LHITES |
| COMMERCIAL POWER INSPECTION | 07/14/2011 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/14/2011 2:31:44 PM FOR POWER ON HOUSE PANEL ONLY..METER CAN #9.CALLED SUSAN FROM FPL FOR POWER RELEASE. | |||
| SECOND ROUGH PLUMBING INSPECTION | 07/14/2011 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 7/14/2011 2:31:45 PM FRONT OF BUILDING CLEANOUT FOR SANITARY. | |||
| COMMERCIAL POWER INSPECTION | 07/11/2011 | Disapproved -FEE REQUIRED | LHITES |
| Note: ok per Joe MC Inspection Resulted at 7/11/2011 9:40:44 AM 1. HOUSE PANEL IS INCOMPLETE. METER CAN MUST HAVE DISCONNECT BREAKER INSTALLED. | |||
| FIREWALL INSPECTION | 07/11/2011 | APPROVED | LHITES |
| INSULATION INSPECTION | 06/20/2011 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/20/2011 1:34:07 PM REMAINDER OF EXTERIOR WALLS. | |||
| FRAMING | 06/17/2011 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/17/2011 2:59:35 PM PARTITION WALL.....OK | |||
| STOREFRONT | 06/13/2011 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 6/13/2011 2:38:08 PM WAITED TILL A FEW WERE TIGHTENED.........DR | |||
| INSULATION INSPECTION | 06/07/2011 | PARTIALLY APPROVED | DROCKWELL |
| Note: Inspection Resulted at 6/7/2011 3:01:01 PM INSULATION NORTH AND WEST WALLS....OK | |||
| 2ND ROUGH ELECTRICAL | 05/27/2011 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/27/2011 2:36:11 PM NEED REVISION SHOWING SWITCHES TO SOFFIT LIGHTING | |||
| ELECTRIC FEEDER | 05/27/2011 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 5/27/2011 2:36:10 PM FEEDER PANEL | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 04/28/2011 | PARTIALLY APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/28/2011 2:26:41 PM WEST WALL,ALL REAR OF BUILDING,FRONT EXCEPT COLUMNS AND LAST 2 STOREFRONTS | |||
| 2ND ROUGH ELECTRICAL | 04/25/2011 | CANCELLED BY APPLICANT | RMARVEL |
| Note: Inspection Resulted at 4/25/2011 2:34:26 PM NOT READY. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 04/25/2011 | PARTIALLY APPROVED | DROCKWELL |
| Note: Inspection Resulted at 4/25/2011 3:02:24 PM BACK NORTH WALL ONLY | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 04/20/2011 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 4/20/2011 3:10:31 PM PARTIAL ON DENS GLAS PER REVISION REAR ONLY | |||
| FRAMING | 04/20/2011 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/20/2011 3:10:32 PM FRONT AND RIGHT SIDE EXTERIOR WALL FRAMING ONLY | |||
| FRAMING | 02/24/2011 | CANCELLED BY APPLICANT | CMINI |
| SIDEWALK | 02/24/2011 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/24/2011 1:43:17 PM SIDEWALK AT FRONT ENTRANCES..CHECKED SLOPE | |||
| SIDEWALK | 02/23/2011 | CANCELLED BY APPLICANT | JCOLASANTI |
| PROJECT STATUS INSPECTION | 02/23/2011 | Disapproved - NO FEE | JCOLASANTI |
| Note: Inspection Resulted at 2/23/2011 3:46:34 PM SILT FENCE VARIOUS PLACES AROUND SITE NEEDS TO BE REPAIRED. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 01/31/2011 | APPROVED | CMINI |
| FOOTER | 01/31/2011 | CANCELLED BY APPLICANT | CMINI |
| Note: requested by TOM | |||
| TEMPORARY POLE | 01/31/2011 | APPROVED | CMINI |
| Note: requeste by Tom Inspection Resulted at 1/31/2011 3:27:07 PM CALLED FPL SUSAN AT 3;30 PM.KDS ELEC | |||
| UNDERGROUND ELECTRICAL | 01/18/2011 | PARTIALLY APPROVED | CMINI |
| Note: requested by TOM Inspection Resulted at 1/18/2011 3:27:07 PM UNDERSLAB CONDUIT AND UNDER SIDEWALK CIRCLED ON PLAN. | |||
| FIRST ROUGH PLUMBING INSPECTION | 01/13/2011 | APPROVED | RMARVEL |
| Note: REQUESTED BY TOM |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 11/21/2011 | 11/21/2011 |
| SW1 | COMPLETE | 11/21/2011 | 11/21/2011 |
| UD1 | COMPLETE | 11/21/2011 | 11/23/2011 |
| BLD | COMPLETE | 11/21/2011 | 11/21/2011 |
| ENGIN1 | COMPLETE | 11/21/2011 | 11/21/2011 |
| PLLA | COMPLETE | 11/03/2011 | 11/04/2011 |
| Note: Approved as submitted | |||
| BLD | COMPLETE | 10/04/2011 | 10/04/2011 |
| ZON | COMPLETE | 10/04/2011 | 10/04/2011 |
| Note: No zoning review needed. | |||
| BLD | HOLD | 06/03/2011 | 06/03/2011 |
| Note: Held by J. Hindman 1. The 2 hour wall is required for the occupancy of the building. | |||
| BLD | COMPLETE | 04/13/2011 | 04/13/2011 |
| Note: Released by JJoseph | |||
| BLD | COMPLETE | 04/13/2011 | 04/13/2011 |
| Note: Released By: JJOSEPH application specs for densglass and stucco | |||
| BLD | HOLD | 04/04/2011 | 04/04/2011 |
| Note: Provide fastening schedule for dense glass and provide detailed drawing of the wire lath method. | |||
| BLD | HOLD | 03/29/2011 | 03/29/2011 |
| Note: Held by J. Hindman 1Provide detailed drawing that shows the components of the wall including all fasteners. The drawing must be suitable for review and inspection of the wall. | |||
| BLD | COMPLETE | 03/23/2011 | 03/24/2011 |
| BLD | COMPLETE | 01/28/2011 | 01/28/2011 |
| Note: Joe M. | |||
| MECH | COMPLETE | 12/16/2010 | 12/16/2010 |
| Note: Released By: FREODICA Energy calcs | |||
| ELEC | COMPLETE | 12/15/2010 | 12/15/2010 |
| Note: Released By: LHITES wire size corrected copper label | |||
| MECH | HOLD | 12/14/2010 | 12/14/2010 |
| Note: Held By: FREODICA correction- hvac not installed at this time letter submittted Correction comment: Energy calculation is still required even if no hvac system is installed at this time. emailed @2:31, 12-14-10 | |||
| ELEC | HOLD | 12/13/2010 | 12/13/2010 |
| Note: Held By: LHITES 1. Conductors and grounding wire sizes are incorrect for HP panel. 2. Please clarify conductor type for TP2 panel so that grounding conductor size can be verified. 3. Load calculations show load for water heaters. Please verity weather or not the heaters are being installed and revise accordingly if not being installed. | |||
| UD1 | COMPLETE | 12/13/2010 | 12/13/2010 |
| Note: Released By: CJOHNSON Plumbing layout | |||
| BLD | COMPLETE | 12/13/2010 | 12/14/2010 |
| Note: Released By: JJOSEPH correction - revised occp load calcs | |||
| PLUM | COMPLETE | 12/10/2010 | 12/13/2010 |
| Note: Released By: FREODICA Correction: a. Sanitary & domestic water rough layout only for the future bathrooms. b. Updated plumbing code edition. | |||
| PLUM | HOLD | 12/09/2010 | 12/09/2010 |
| Note: Held By: FREODICA 1. Provide sanitary riser diagram complete with vent system and pipe sizes. 2. Provide domestic water riser diagram including location of water heater, hot water system and pipe sizes. 3. Revise Plumbing Code Edition from 2004 to 2007 as shown on Job Note B. emailed @ 12:52, 12-9-10 | |||
| BLD | HOLD | 12/09/2010 | 12/09/2010 |
| Note: Held By: JJOSEPH 1.Revise the oocupant load calculation as per table 1004.1 of FBC 2007/w supplement 2009. 2. Indicate if the building is sprinklered or not.( type IIA or IIB) Faxed and E-mailed at 2:18PM on 12/09/2010 | |||
| FI1 | COMPLETE | 10/08/2010 | 11/28/2011 |
| UD1 | HOLD | 10/06/2010 | 10/06/2010 |
| Note: Held By: CJOHNSON Provide plumbing plan. Has it been determined what unit will have food preparation and will utilize the grease interceptor? Any unit proposed to prepare and/or serve food will require an individual grease interceptor installed exterior to the building. Refer to City standards manual for sizing requirements | |||
| BLD | HOLD | 10/04/2010 | 10/04/2010 |
| Note: Held By: JMCGOWEN coordinate plans and provide plans with detail suitable for review, construction and inspection | |||
| ELEC | HOLD | 10/04/2010 | 10/04/2010 |
| Note: Held By: JMCGOWEN provide electric riser detail and load calculations | |||
| MECH | HOLD | 10/01/2010 | 10/01/2010 |
| Note: Held By: FREODICA 1. Provide energy calculations of the proposed shell building. If hvac duct sytem would be done in the future, indicate on plans. Faxed & emailed @ 9:19, 10-1-10 | |||
| PLUM | HOLD | 10/01/2010 | 10/01/2010 |
| Note: Held By: FREODICA 1. Provide plumbing plans suitable for review including but not limited to the following: a. Sanitary layout & riser diagram. b. Domestic water & riser diagram. c. Fixture & piping material specifications. Emailed @ 9:22, 10-1-10 | |||
| ZON | COMPLETE | 10/01/2010 | 10/05/2010 |
| Note: Released By: CBENTLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADDITIONAL FEE | ¤40.00 | 12/01/2011 |
| REINSPECTION FEE | ¤40.00 | 12/01/2011 |
| REINSPECTION FEE | ¤40.00 | 12/01/2011 |
| REINSPECTION FEE | ¤40.00 | 12/01/2011 |
| REVISION | ¤40.00 | 12/01/2011 |
| REVISION | ¤40.00 | 12/01/2011 |
| REVISION | ¤40.00 | 12/01/2011 |
| REVISION | ¤40.00 | 12/01/2011 |
| REVISION | ¤40.00 | 12/01/2011 |
| TRANSPORTATION IMPACT FEE | ¤30,539.77 | 12/01/2011 |
| SITE PLAN 20 | ¤20.00 | 12/17/2010 |
| SURCHARGE FS 533.721 | ¤66.98 | 12/17/2010 |
| SURCHARGE - FS 468.631 | ¤66.98 | 12/17/2010 |
| TRANSPORTATION IMPACT FEE | ¤30,539.77 | 12/17/2010 |
| ADMIN COMMERCIAL | ¤60.00 | 12/17/2010 |
| BUILDING DISCOUNT 100% | (¤4,018.50) | 12/17/2010 |
| ELECTRIC FEE | ¤360.00 | 12/17/2010 |
| FIRE PLANS REVIEW | ¤118.31 | 12/17/2010 |
| FIRE IMPACT FEE RES 4/1/10 | ¤6,239.67 | 12/17/2010 |
| MECHANICAL FEE | ¤360.00 | 12/17/2010 |
| PERMIT FEE | ¤2,750.00 | 12/17/2010 |
| PLAN CHECK FEE | ¤575.00 | 12/17/2010 |
| PLUMBING FEE | ¤360.00 | 12/17/2010 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤68,397.98 |