Permit #2010100304

Permit Details

Status: COED

Parcel Id: 39-12-31-0000-04030-0000
Total Square Footage: 200 sqft
Block: 04030
Subdivision: -
Job Phone: 386-453-0736
Location Address: 511 OLD KINGS RD
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 11/16/2010
NOC: RECORDED
Applicant name: GARY LYNN ROBERTS
Owner: FLAGLER PALMS CEMETERY LLC

Address

511 OLD KINGS RD S

FLAGLER BEACH, FL 32136

Lot: 0000
Contracted Stated Job Value: ¤29,000.00
Job Description: CRAIG FLAGLER PALMS-CREMATORY OVEN AND DUCTWORK
Type: CN

Contractor

COMMERCIAL CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

7 SUNSHINE BLVD

ORMOND BEACH, FL 32174

CGC059441 (Exp: 08/31/2026) 386-238-1570 386-238-1571

Sub Contractors

MIKE F WHALEY
Status Location Address State License Number Phone Fax
ACTIVE

804 Root Street

Daytona Beach, FL 32114

EC0001334 (Exp: 08/31/2026) (386) 252-2287 (386)257-1920
VERNON CARROLL MONDAY
Status Location Address State License Number Phone
CANCEL

530 GRAND STREET

ORLANDO, FL 32805

CAC010842 (Exp: 08/31/2016) 386-322-6168
DAVID CASH
Status Location Address State License Number Phone Fax
CANCEL

45 SOUTH DIXIE HIGHWAY

ST. AUGUSTINE, FL 32084

01613 (Exp: 08/31/2014) (386)437-3433 904-829-1844

Inspection History

Type Request Date Result Inspector
COMMERCIAL BUILDING FINAL 01/21/2011 FINAL APPROVED RMARVEL
UTILITY COMMERCIAL FINAL 01/21/2011 APPROVED DSPENCER
UTILITY COMPANY FINAL 01/21/2011 APPROVED DSPENCER
FIRE FINAL 01/21/2011 APPROVED LHITES
GAS ROUGH 01/18/2011 APPROVED CMINI
Note: THIS IS A REINSPECTION
GAS FINAL 01/18/2011 APPROVED CMINI
ABOVE CEILING 01/12/2011 APPROVED RMARVEL
2ND ROUGH ELECTRICAL 01/12/2011 APPROVED RMARVEL
ELECTRICAL FINAL 01/12/2011 APPROVED RMARVEL
GAS ROUGH 01/12/2011 CANCELLED BY APPLICANT RMARVEL
MONOLITHIC SLAB INSPECTION/SLAB 11/22/2010 APPROVED LHITES
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 11/18/2010 Disapproved -FEE REQUIRED LHITES
Note: 1. Need detail showing installed hooks (size,placement,and attachment) 2. Need revised statement or drawing showing use of WWF or alternate method

Review History

Department Status Date In Date Out
BLD COMPLETE 11/19/2010 11/19/2010
Note: Released By: LHITES Revision- add hook rebar into exisiting slab
ELEC COMPLETE 11/04/2010 11/08/2010
Note: Released By: LHITES
MECH COMPLETE 11/03/2010 11/04/2010
Note: Released By: FREODICA Propane tank riser diagram & detail w/specs (above ground) (2) M-P.1 clarification w/letter
FI1 COMPLETE 10/21/2010 10/28/2010
Note: Released By: LHITES
UD1 COMPLETE 10/20/2010 10/20/2010
Note: Released By: CJOHNSON
ELEC HOLD 10/19/2010 10/19/2010
Note: Held By: LHITES 1. Please provide complete electrical riser diagram showing panel size and location as well as wire size,type. 2. Please provide complete load calculations. 3. Drawings should show all of existing electric also.
BLD COMPLETE 10/15/2010 10/15/2010
Note: Released By: JJOSEPH
MECH HOLD 10/15/2010 10/15/2010
Note: Held By: FREODICA 1. Indicate on plan which method of air supply will be used for cremation equipment provided by manufacturer. Is it standard method (sheet 1 of 2) or ducted combustion air method (sheet 2 of 2). If ducted combustion air method would be used, provide duct size. 2. Provide detail or manufacturer's installation instructions for self-propelled turbines on the roof. 3. Crematories shall be listed & labeled in accordance with UL 791 and shall be installed in accordance with the manufacturer's installation instructions per FMC 2007 Section 907. Provide another (1) set of manufacturer's installation instruction. 4. Provide gas sub-contractor and gas riser diagram showing pipe size, material, and all components required. faxed @ 2:09, 10-15-10
ZON COMPLETE 10/12/2010 10/14/2010
Note: Released By: CBENTLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/18/2011
REVISION ¤40.00 01/18/2011
SITE PLAN 20 ¤20.00 11/16/2010
SURCHARGE FS 533.721 ¤7.77 11/16/2010
SURCHARGE - FS 468.631 ¤7.77 11/16/2010
ADMIN COMMERCIAL ¤60.00 11/16/2010
BUILDING DISCOUNT 100% (¤466.02) 11/16/2010
ELECTRIC FEE ¤77.40 11/16/2010
FIRE PLANS REVIEW ¤25.00 11/16/2010
MECHANICAL FEE ¤77.40 11/16/2010
PERMIT FEE ¤203.00 11/16/2010
PLAN CHECK FEE ¤100.00 11/16/2010
Fees Total Due: ¤0.00 Total Paid: ¤192.32