Permit #2010100591

Permit Details

Status: COED

Parcel Id: 06-12-31-5815-00000-0230
Block: 00000
Subdivision: 2118 - Town Center Phase I
Job Phone: 386-338-7785
Location Address: 57 TOWN CT
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 11/09/2010
NOC: RECORDED
Applicant name: THOMAS M SCAGLIONE
Owner: UNION C TRUST LLC

Address

28 ST ANDREWS COURT

PALM COAST, FL 32137

Lot: 0230
Contracted Stated Job Value: ¤62,500.00
Job Description: SUITES 2A THRU 2M- COMMERICIAL INTERIOR BUILDOUT "GOD'S FAMILY BIBLE CHURCH"
Type: CN

Contractor

T-CON GROUP, INC.
Status Location Address State License Number Phone
CANCEL

3246 NORTH POWERLINE ROAD

POMPANO BEACH, FL 33069

CBC1251999 (Exp: 08/31/2020) 954-825-8369

Sub Contractors

WILLIAM M MCGILL III
Status Location Address State License Number Phone Fax
CANCEL

66 WOODSIDE DRIVE

PALM COAST, FL 32164

EC13003476 (Exp: 08/31/2018) 386-931-6969 386-447-6969
MICHAEL ALLEN PHILLIPS
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 478

BUNNELL, FL 32110

CAC1814966 (Exp: 08/31/2014) 386-262-6034 866-369-7390
JOHN CHARLES GRAY
Status Location Address State License Number Phone Fax
ACTIVE

2707 ANNETTE STREET

FLAGLER BEACH, FL 32136

CFC1425975 (Exp: 08/31/2026) (386)793-3690 (386)439-7585

Inspection History

Type Request Date Result Inspector
FIRST ROUGH PLUMBING INSPECTION 05/25/2011 APPROVED RMARVEL
HVAC ROUGH 05/25/2011 APPROVED RMARVEL
HVAC FINAL 05/25/2011 APPROVED RMARVEL
ALL ROUGH 05/25/2011 APPROVED RMARVEL
ABOVE CEILING 05/25/2011 APPROVED RMARVEL
Note: THIS IS A REINSPECTION requested by contractor
FIREWALL FINAL INSPECTION 05/25/2011 APPROVED LHITES
Note: THIS IS A REINSPECTION
COMMERCIAL BUILDING FINAL 05/25/2011 FINAL APPROVED RMARVEL
Note: requested by contractor
FIREWALL INSPECTION 05/25/2011 APPROVED LHITES
FIRE FINAL 05/25/2011 APPROVED LHITES
Note: THIS IS A REINSPECTION
FIRE FINAL 05/10/2011 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. provide a full set of plans. 2. the exit lights are not all working. 3. the sprinkler escutcheon plates are not all installed. 4. seal off the empty box in the rated wall outside of the sanctuary.
FIREWALL FINAL INSPECTION 05/10/2011 Disapproved -FEE REQUIRED JHINDMAN
Note: the doors in the rated walls do not match the plans.
UTILITY COMMERCIAL FINAL 05/05/2011 APPROVED DSPENCER
UTILITY COMPANY FINAL 05/05/2011 APPROVED DSPENCER
PLUMBING FINAL 05/05/2011 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
H.V.A.C. FINAL 05/04/2011 APPROVED RMARVEL
PLUMBING FINAL 04/28/2011 PARTIALLY APPROVED RMARVEL
Note: Inspection Resulted at 4/28/2011 12:42:18 PM BATHROOMS.
2ND ROUGH ELECTRICAL 04/15/2011 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
COMMERCIAL POWER INSPECTION 04/01/2011 APPROVED RMARVEL
Note: Inspection Resulted at 4/1/2011 11:37:55 AM CALLED FPL. 9:37
SECOND ROUGH PLUMBING INSPECTION 02/24/2011 APPROVED RMARVEL
2ND ROUGH ELECTRICAL 02/23/2011 PARTIALLY APPROVED RMARVEL
Note: Inspection Resulted at 2/23/2011 3:36:21 PM WALLS AND HALLWAY CEILINGS.
FRAMING 02/23/2011 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ABOVE CEILING 02/23/2011 PARTIALLY APPROVED RMARVEL
Note: Inspection Resulted at 2/23/2011 3:36:21 PM HALLWAYS ONLY
2ND ROUGH ELECTRICAL 02/22/2011 APPROVED RMARVEL
Note: Inspection Resulted at 2/22/2011 3:06:42 PM HALLWAY ONLY
FRAMING 12/27/2010 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 12/27/2010 10:15:55 AM the raised platform in the sound booth is not on the plans. (need detail). The sound booth door has been relocated. The drywall underneath and behind the sound booth platform needs to be taped and finished on the rated walls.
ALL ROUGH 12/27/2010 CANCELLED BY APPLICANT AIRS WEB
FRAMING 11/23/2010 CANCELLED BY APPLICANT CMINI
INSULATION INSPECTION 11/15/2010 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 11/15/2010 3:32:12 PM OUTER WALLS

Review History

Department Status Date In Date Out
ELEC COMPLETE 05/17/2011 05/17/2011
BLD COMPLETE 05/16/2011 05/16/2011
Note: released by J. Hindman
FI1 COMPLETE 05/16/2011 05/16/2011
Note: all ready stamped revison by J Hindman
FI1 COMPLETE 02/17/2011 02/21/2011
ELEC COMPLETE 02/17/2011 02/21/2011
FI1 HOLD 02/10/2011 02/10/2011
Note: 1. Provide manufacturers detail for doors with fire damper.
BLD COMPLETE 02/09/2011 02/10/2011
Note: no building review required for this revision. egress doors will need a revision to be reviewed by fire
ELEC HOLD 02/09/2011 02/10/2011
Note: 1. Provide new electrical riser diagram for service.
MECH COMPLETE 02/09/2011 02/10/2011
Note: the fire dampers will need to be reviewed by fire
BLD COMPLETE 12/10/2010 12/10/2010
Note: Released By: LHITES
FD1 COMPLETE 12/09/2010 12/10/2010
Note: Released By: LHITES REVISED FIRE PROTECTION IN HALLWAY CERTIFICATE OF FIRE
BLD HOLD 12/02/2010 12/02/2010
Note: Held By: LHITES changing the corridor to be non fire rated wall Per Florida building code 2007 with 2009 supplyments footnote C no longer applies to assembly structures.
FD1 HOLD 12/02/2010 12/02/2010
Note: Held By: LHITES correction to the revision - code analysis for fire partion wall Per Florida building code 2007 with 2009 supplyments footnote C no longer applies to assembly structures.
FD1 HOLD 11/17/2010 11/18/2010
Note: Held By: JJOSEPH/ LHITES To our knowledge the automatic sprinkler system at this site is not supervised , therefore foot note "c" does not apply. Faxed and emailed at 8:30AM on 11/18/2010
UD1 COMPLETE 11/09/2010 11/09/2010
Note: Released By: CJOHNSON Letter requested by Chris Johnson
MECH COMPLETE 11/09/2010 11/09/2010
Note: Released By: FREODICA correction- energy calcs, located dampers, shortened flex runs
BLD COMPLETE 11/05/2010 11/05/2010
Note: Released By: JJOSEPH modification on mechanical
MECH HOLD 11/05/2010 11/05/2010
Note: Held By: FREODICA Previous comments dated 11-2-10 need to be addressed as follows: Item 1. Provide revised energy calculations. Item 3. Provide dampers & grilles penetrating rated walls. Comment: Location of dampers shall be indicated on plan. Item 7: Provide insatallation details of equipments & duct supports. Comment: Details submitted do not indicate sizes of hanger rods or straps. Additional Comment due to changes of design layout: 1. RTU-3 & RTU-4: The total distributed supply air in CFM's do not match with the capacity (3000 CFM) of the units. emailed @ 1:16, 11-5-10
FI1 COMPLETE 11/05/2010 11/08/2010
Note: Released By: LHITES modification on firewall
UD1 HOLD 11/03/2010 11/03/2010
Note: Held By: CJOHNSON Will any food preparation be proposed? Please provide information on what will the 2 compartment sink be used for. Any food preparation in the kitchen or bar area will require a 750 gallon grease interceptor. Contact Utility Department 986-2384
BLD HOLD 11/02/2010 11/02/2010
Note: Held By: JJOSEPH 1.The floor plan does not match the life safety plan about the door into the corridor; please revise and make correction. 2. The occupant load is still not correct. Need to show the fixed seating or use the table 1004.1.1 of FBC 2007/ supplement 2009. 3. The corridor needs to be fire rated as per table 1017.1 of FBC 2007/ supplement 2009. 4. The horizontal sliding door needs to comply as per section 1008.1.3.3 of FBC 2007 /supplement 2009 Faxed and Emailed at 12:42PM on 11/02/2010
PLUM COMPLETE 11/02/2010 11/02/2010
Note: Released By: FREODICA
MECH HOLD 11/02/2010 11/02/2010
Note: Held By: FREODICA 1. Provide revised energy calculations. 2. Flexible air connectors are limited to maximum of 14 ft per FMC 2007 Section 603.5.2.1. 3. Provide dampers for ducts & grilles penetrating rated walls. Provide details. 4. Provide hvac equipments specifications. 5. Provide information on how condensate from all roof top units (RTU's) would be discharged. 6. Provide fresh air intake duct layout, CFM's, duct size for AHU-1. 7. Provide installation details of equipments, & duct supports. emailed@1:17, 11-2-10 -contractor emailed @ 1:57, 11-2-10- Pastor (Abolajiakinbo@gmail.com) per his request.
ELEC COMPLETE 11/02/2010 11/02/2010
Note: Released By: LHITES
FI1 HOLD 11/02/2010 11/02/2010
Note: Held By: LHITES 1. Need existing sprinkler layout to determine clearance and need of additional sprinkler heads. 2. Need alarm system layout to determine if additional horns and or strobes and emergency pulls are needed. 3. Add exit combo light at door outside of conference room. 4. Exit signs needed over doors at food pantry, maintenance office, and music studio doors.
FI1 HOLD 10/28/2010 10/28/2010
Note: Held By: LHITES Plans do not show means of egress distances. Need height and area of raised platform to determine FBC sections 410.4 and 410.6. Also need ramp detail.
UD1 HOLD 10/28/2010 11/01/2010
Note: Held By: CJOHNSON Will any food preparation be proposed? Please provide information on what will the 2 compartment sink be used for. Any food preparation in the kitchen or bar area will require a 750 gallon grease interceptor.
MECH HOLD 10/26/2010 10/26/2010
Note: Held By: FREODICA 1. Revise energy calculations to match the number of units to be used. Please note that hot water heater is indicated to be 50 gallons but per contractor insta-hot would be used. Please coordinate & revise. 2. Revised set of HVAC plans will be submitted per contractor.
PLUM HOLD 10/26/2010 10/26/2010
Note: Held By: FREODICA 1. Revise occupant load calculation based on assembly occupancy to determine the required number of plumbing fixtures per FPC 2007 Table 403.1. 2. Provide hot water layout and riser diagram.
BLD HOLD 10/26/2010 10/26/2010
Note: Held By: JJOSEPH 1.Provide fire wall Penetration details including the UL number. 2.The occupancy classification submitted should be A-3, please revise and redesign accodingly., Precise the type of construction if it's IIIA or IIIB. 3.Provide a life safety plan including measurements, travel distance, egress width per table 1005.1 4.Provide platform risers and guardrails details. 5.Any door swings in a means of egress shall leave unobstructed at least one half of the required width of corridor (section 1008.1.8.8 of FBC 2007)
ELEC HOLD 10/26/2010 10/28/2010
Note: Held By: LHITES 1.Sheet E-2- Load calculations are incorrect. 2. circuit P1-15 is doubled 3. circuit P4-13 is doubled 4. circuit P4-14 is tripled 5. circuit P4-15 is doubled 6. circuit P4-16 is doubled 7. circuit P4-18 is shown as an outlet yet panel schedule shows it as HWH 8. Load calculation for panel 3 and 4 does not show load for subpanel.
ZON COMPLETE 10/25/2010 10/26/2010
Note: Released By: JGONZALEZ Meets required parking and no differnce in impact fee.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/25/2011
REINSPECTION FEE ¤40.00 05/25/2011
REINSPECTION FEE ¤40.00 05/25/2011
REVISION ¤40.00 05/25/2011
REVISION ¤40.00 05/25/2011
REVISION ¤40.00 05/25/2011
REVISION ¤40.00 05/25/2011
SITE PLAN 20 ¤20.00 11/09/2010
SURCHARGE FS 533.721 ¤13.35 11/09/2010
SURCHARGE - FS 468.631 ¤13.35 11/09/2010
ADMIN COMMERCIAL ¤60.00 11/09/2010
BUILDING DISCOUNT 100% (¤801.00) 11/09/2010
ELECTRIC FEE ¤97.50 11/09/2010
FIRE PLANS REVIEW ¤25.00 11/09/2010
MECHANICAL FEE ¤97.50 11/09/2010
PERMIT FEE ¤437.50 11/09/2010
PLAN CHECK FEE ¤100.00 11/09/2010
PLUMBING FEE ¤97.50 11/09/2010
Fees Total Due: ¤0.00 Total Paid: ¤440.70