Permit #2011030566

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00130-0080
Block: 00130
Subdivision: 2185 - SECTION 7-FLORIDA PARK
Job Phone: (904)824-1468
Location Address: 104 FORSYTHE LN
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 04/29/2011
NOC: RECORDED
Applicant name: JOHN E BUENING
Owner: DUPUY STEPHEN M & MARCIA L TENNYSON DUPUY H&W

Address

104 FORSYTHE LANE

PALM COAST, FL 32137

Address

TRUSTEES

PALM COAST, FL 32137

Lot: 0080
Contracted Stated Job Value: ¤185,000.00
Job Description: BUILDING INTERIOR REPAIRS DUE TO FIRE DAMAGE
Type: CN

Contractor

PAUL DAVIS RESTORATION OF ST. AUGUSTINE
Status Location Address State License Number Phone Fax
ACTIVE

2050 DOBBS ROAD

ST. AUGUSTINE, FL 32086

CGC056634 (Exp: 08/31/2026) (904)824-1468 (904)823-9586

Sub Contractors

EDWARD S JACKSON
Status Location Address State License Number Phone Fax
CANCEL

2151 DOBBS ROAD #6

ST. AUGUSTINE, FL 32086

CFC1427661 (Exp: 08/31/2016) 904-829-9076 904-829-9078
JOHN EUGENE BUENING
Status Location Address State License Number Phone
CANCEL

2139 Dobbs Road Unit 1

St. Augustine, FL 32086

CCC056947 (Exp: 08/31/2024) (386) 824-1468
GUY A BARRETTE
Status Location Address State License Number Phone Fax
CANCEL

880 AIRPORT RD UNIT 109

ORMOND BEACH, FL 32174

EC0001966 (Exp: 08/31/2016) 386-677-7876 386-263-8838
DOUGLAS A JAHN
Status Location Address State License Number Phone
CANCEL

34 LYNBROOK DR

BUNNELL, FL 32110

CAC058261 (Exp: 08/31/2018) (386) 446-5123

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/26/2011 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 10/25/2011 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 10/25/2011 11:56:02 AM INSTALL EXPANSION TANK OR VALVE AT NEW WATER HEATER/COVER AT ATTIC ACCESS STAIRS IN GARAGE MUST BE FIRE RATED/SEAL AROUND A/C DUCTS GARAGE CEILING/INSTALL VACUME BREAKERS AT NEW HOSE BIBBS/INSTALL SHOCK ARRESTOR AT DISHWASHER/WINDOWS NOT IMPACT RATED-PLANS SHOW PLYLOX CLIP SYSTEM AND 1/2 IN PLYWOOD PANELS EACH WINDOW-THIS SYSEM TO BE ON SITE AT FINAL INSPECTION/EXPOSED NM CABEL UNDER CABINET AT DISPOSAL MUST BE IN ELECT BOX WITH COVER.
RESIDENTIAL EARLY POWER 10/11/2011 APPROVED CMINI
Note: Inspection Resulted at 10/11/2011 2:59:33 PM CALLED FPL TO RELEASE POWER SPOKE WITH SUSAN...GUY BARRET ELEC.
INSULATION 07/14/2011 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 07/13/2011 Disapproved -FEE REQUIRED DROCKWELL
Note: REQUESTED BY CONTRACTOR Inspection Resulted at 7/13/2011 1:04:13 PM MISSING YARDSTICKS FOR BLOWN INSULATION THROUGH-OUT/DRAFTSTOP TOP PLATE HOLES SEE GREEN PAINT/FIRESTOPPING MISSING AT ELECTRICAL PANEL INTO CEILING/R-30 INSULATION UNDER BAFFELS IN EAT IN KITCHEN AREA MISSING/RUN PROPER WIRING TO CONDENSATE UNIT FROM DISCONNECT
ALL ROUGH 07/08/2011 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 7/8/2011 2:28:33 PM EXHAUST DUCTS NOT HOOKED UP/RUN ELECTRIC TO A/C CONDENSING UNIT
ALL ROUGH 06/23/2011 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 6/23/2011 3:14:38 PM FILL A/C CHSAE WITH APPROPRIATE MATERIAL/COMPLETE FURRING AND NAIL PLATES IN MASTER BATH/EXHAUST DUCT NOT INSTALLED IN MASTER BATH/PLANS SHOW SLIDING DOOR ON GUEST BED TO PORCH/CAN LIGHTS IN KITCHEN NOT ON PLAN/COMPLETE GFI IN GARAGE/EXHAUST DUCT IN GUEST BATH NOT INSTALLED/NEED HEAD TEST ON SANITARY PLUMBING/ALL WINDOWS TO BE REPLACED ACCORDING TO PLAN MUST INSTALLED BY THIS INSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/01/2011 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 6/1/2011 3:06:39 PM COMPLETE LATERAL BRACING AT TRUSSES/REMOVE SHINNERS AT ROOR DECK/STRAPT-16 T-19 GEDO2 AND RE-STRAP GIRDER T-18 IN GARAGE INSIDE-WILL CHECK AT NEXT INSPECTION.
LINTEL 05/06/2011 APPROVED CMINI

Review History

Department Status Date In Date Out
ZON COMPLETE 07/01/2011 07/01/2011
ELEC COMPLETE 07/01/2011 07/01/2011
Note: released by J. Hindman
BLD COMPLETE 07/01/2011 07/01/2011
Note: released by J. Hindman
ELEC COMPLETE 04/27/2011 04/28/2011
MECH COMPLETE 04/27/2011 04/28/2011
Note: Released by Freodica
MECH HOLD 04/25/2011 04/25/2011
Note: Held by Freodica 1. Provide return air from (2) rooms (unnamed). 2. Provide location of condenser unit.
BLD COMPLETE 04/25/2011 04/25/2011
ELEC HOLD 04/25/2011 04/25/2011
Note: Held by J. Hindman 1 provide a carbon monoxide detector outside of bedrooms.
PLUM COMPLETE 04/13/2011 04/13/2011
Note: Released by Freodica
BLD HOLD 04/13/2011 04/13/2011
Note: Held by Freodica 1. All Florida Product Approval for windows and doors shall be accompanied by manufacturer's installation instructions. 3. Provide Florida Product Approval for shutters.
ELEC HOLD 04/13/2011 04/13/2011
Note: Provide electric load calculations, electric riser detail, outlet, light and detector location. Provide grounding system detail
MECH HOLD 04/13/2011 04/13/2011
Note: Held by Freodica 1. Provide hvac duct system layout including duct sizes and CFM's. If designed by hvac contractor, the plan shall have his/her signature and license number. 2. Provide signature on Energy Performance Level (EPL) Display Card.
PLUM HOLD 03/23/2011 03/23/2011
Note: Held by J.Hindman.1. Provide detailed scope of work. 2.Provide plans for any Electrical, Mechanical and Plumbing work. 3. The proposed windows are not impact resistant,provide product approvals for shutters. 4. Provide energy calaculations. 5. Provide attic ventilation calculations. 6. Provide egress window opening sizes.
ZON COMPLETE 03/23/2011 03/24/2011
Note: No zoing review required
ELEC HOLD 03/23/2011 03/23/2011
Note: Held by J.Hindman.1. Provide detailed scope of work. 2.Provide plans for any Electrical, Mechanical and Plumbing work. 3. The proposed windows are not impact resistant,provide product approvals for shutters. 4. Provide energy calaculations. 5. Provide attic ventilation calculations. 6. Provide egress window opening sizes.
MECH HOLD 03/23/2011 03/23/2011
Note: Held by J.Hindman.1. Provide detailed scope of work. 2.Provide plans for any Electrical, Mechanical and Plumbing work. 3. The proposed windows are not impact resistant,provide product approvals for shutters. 4. Provide energy calaculations. 5. Provide attic ventilation calculations. 6. Provide egress window opening sizes.
BLD HOLD 03/23/2011 03/23/2011
Note: Held by J.Hindman.1. Provide detailed scope of work. 2.Provide plans for any Electrical, Mechanical and Plumbing work. 3. The proposed windows are not impact resistant,provide product approvals for shutters. 4. Provide energy calaculations. 5. Provide attic ventilation calculations. 6. Provide egress window opening sizes.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/25/2011
REINSPECTION FEE ¤40.00 10/24/2011
REINSPECTION FEE ¤40.00 07/07/2011
REVISION ¤40.00 07/07/2011
SITE PLAN 20 ¤20.00 04/29/2011
SURCHARGE FS 533.721 ¤2.00 04/29/2011
SURCHARGE - FS 468.631 ¤2.00 04/29/2011
REMODEL/ADDITION/ACCES INSPECT ¤74.00 04/29/2011
CONTRACTOR CHANGE ¤40.00 04/29/2011
CONTRACTOR CHANGE ¤40.00 04/29/2011
BUILDING DISCOUNT 100% (¤612.90) 04/29/2011
ELECTRIC FEE ¤171.00 04/29/2011
MECHANICAL FEE ¤171.00 04/29/2011
PERMIT FEE ¤20.00 04/29/2011
PLAN CHECK FEE ¤74.00 04/29/2011
PLUMBING FEE ¤171.00 04/29/2011
Fees Total Due: ¤0.00 Total Paid: ¤332.10