Permit #2011030625
Permit Details
Status: COED
| Parcel Id: 14-11-30-5540-00000-00B0 |
| Total Square Footage: 7900 sqft |
| Block: 00000 |
| Subdivision: 1188 - ST JOE PLAZA AT PC |
| Job Phone: (386)677-8736 |
| Location Address: 229 ST JOE PLAZA DR SW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 05/02/2011 |
| NOC: RECORDED |
| Applicant name: LEONARD MARINACCO |
| Owner: ST JOE PLAZA INC |
|
Address 76-36 265TH ST NEW HYDE PARK, NY 11040 |
| Lot: 00B0 |
| Contracted Stated Job Value: ¤125,000.00 |
| Job Description: # 229 - PARTITION /CEILINGS /OUTLETS /LIGHT FIXTURES./ AC DUCTWORK 'AARONS RENT STORE' |
| Type: CN |
Contractor
BOMAR CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
27 S ORCHARD STREET ORMOND BEACH, FL 32174 |
CGC015648 (Exp: 08/31/2022) | (386)677-8736 | (386)677-7726 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
317 RIO PINR DR Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2026) | 386-233-1553 | 386-673-5994 |
DONALD G MEYER
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Drawer 730008 Ormond Beach, FL 32174 |
CAC039739 (Exp: 08/31/2016) | (386) 253-7774 |
ISAAC WALTER JOHNSTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
887 BRENTWOOD DRIVE Daytona Beach, FL 32117 |
CFC023634 (Exp: 08/31/2026) | (386) 252-7047 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC OTHER | 06/20/2011 | APPROVED | JMCGOWEN |
| Note: test and balance report on file | |||
| COMMERCIAL BUILDING FINAL | 06/20/2011 | FINAL APPROVED | LHITES |
| UTILITY COMMERCIAL FINAL | 06/17/2011 | APPROVED | DSPENCER |
| UTILITY COMPANY FINAL | 06/17/2011 | APPROVED | DSPENCER |
| ELECTRIC FINAL | 06/17/2011 | APPROVED | LHITES |
| HVAC FINAL | 06/17/2011 | APPROVED | LHITES |
| FIRE FINAL | 06/16/2011 | APPROVED | LHITES |
| ABOVE CEILING | 06/13/2011 | APPROVED | LHITES |
| HVAC ROUGH | 06/13/2011 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC - EARLY POWER | 06/08/2011 | APPROVED | LHITES |
| Note: REQUESTED BY CONTRACTOR | |||
| HVAC ROUGH | 06/02/2011 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 6/2/2011 2:30:26 PM NEED REVISION SHOWING CHANGE IN DUCT LAYOUT TO PLANS. ALSO FOR CHANGE OF SUPPORT STRAPPING FOR FLEX DUCT. MISSING FLEX DUCT ON 2 AREAS AT RETURNS. | |||
| ELECTRIC 2ND ROUGH | 05/23/2011 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/23/2011 3:06:44 PM WALL RECEPTS.ONLY | |||
| ELECTRIC 2ND ROUGH | 05/19/2011 | PARTIALLY APPROVED | CMINI |
| Note: Charlie called me to schedule this inspection Inspection Resulted at 5/19/2011 3:50:46 PM PARTIAL ON RECEPTACLES ON NEW FRAMED WALL | |||
| FRAMING | 05/19/2011 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 5/19/2011 2:44:38 PM FRAMING FOR SEPARATION WALL ,NEED REVISION FOR SOFFIT FRAMING | |||
| MONOLITHIC SLAB | 05/10/2011 | APPROVED | CMINI |
| ELECTRIC 1ST ROUGH | 05/06/2011 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 5/6/2011 2:52:23 PM UNDERSLAB | |||
| FIRST ROUGH PLUMBING INSPECTION | 05/04/2011 | APPROVED | CMINI |
| SECOND ROUGH PLUMBING INSPECTION | 05/04/2011 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 5/4/2011 3:00:17 PM NEED REVISION BY PLUMBING FINAL SHOWING D.F IN DIFFERENT LOCATION |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/16/2011 | 06/16/2011 |
| PLUM | COMPLETE | 06/10/2011 | 06/10/2011 |
| BLD | COMPLETE | 06/09/2011 | 06/10/2011 |
| PLUM | HOLD | 06/09/2011 | 06/10/2011 |
| Note: Provide drawing of maneuvering space in front and sides of water fountain as per figure 27 b,c or d. figure b shows side wall extensions to be 24 inches max. so c and d options are to choose from. | |||
| BLD | HOLD | 06/07/2011 | 06/08/2011 |
| Note: Held by J. Hindman 1. provide detail for fastening soffit to the hollow core deck. | |||
| MECH | COMPLETE | 06/07/2011 | 06/08/2011 |
| PLUM | HOLD | 06/07/2011 | 06/08/2011 |
| Note: Revise drawing to meet the intent of FBC chapter 11 figure 27 | |||
| MECH | COMPLETE | 04/05/2011 | 04/06/2011 |
| Note: Released by Freodica | |||
| MECH | HOLD | 04/01/2011 | 04/04/2011 |
| Note: Held by Freodica 1. Total area in square feet (6216 SF) used in outdoor air ventilation calculation does not matched with the total conditioned space area (7760 SF) used in energy calculation. Please clarify and coordinate. | |||
| ELEC | COMPLETE | 04/01/2011 | 04/04/2011 |
| Note: released by l. hites | |||
| FI1 | COMPLETE | 04/01/2011 | 04/04/2011 |
| PLUM | COMPLETE | 04/01/2011 | 04/04/2011 |
| Note: Released by Freodica | |||
| BLD | COMPLETE | 04/01/2011 | 04/04/2011 |
| Note: released by J. Hindman | |||
| BLD | HOLD | 03/25/2011 | 03/25/2011 |
| Note: Held By: JHINDMAN On hold by J.Hindman per the site visit at 10 a.m. with Joe Mcgowen, Larry Hites, and Rick from Bomar.1. Provide a second floor plan showing the proposed use and modification to the space.2. Ductwork on the second floor blocks the exit sign.3.Provide remedy for the unusable second floor exterior door.4.Provide a third party engineering cerification of the new block openings in the exterior walls.5. Provide confirmation that the fire department has been notified that the sprinkler system in not active. | |||
| SW1 | COMPLETE | 03/24/2011 | 03/25/2011 |
| Note: Released by JJoseph No stormwater review (interior aletration) | |||
| UD1 | COMPLETE | 03/24/2011 | 03/24/2011 |
| ZON | COMPLETE | 03/24/2011 | 03/28/2011 |
| ELEC | HOLD | 03/24/2011 | 03/25/2011 |
| Note: 1. Provide exit sign at upper stair level. 2. Remove exit sign leading to back room. 3. A/C and A/H are shown on same circuits. 4. Panel schedule does not show A/H or A/C circuits. 5. Will need new load calculations for panel once schedule is corrected. 6. 4/0 aluminum is incorrect size for commercial 200 amp panel. | |||
| FI1 | HOLD | 03/24/2011 | 03/25/2011 |
| Note: 1. Provide extinguisher locations | |||
| MECH | HOLD | 03/24/2011 | 03/24/2011 |
| Note: Held by Freodica 1. Provide energy calculations. 2. Provide required outdoor ventilation air per FMC 2007 Table 403.3 3. Indicate how condensate discharge would be accomplished. | |||
| PLUM | HOLD | 03/24/2011 | 03/25/2011 |
| Note: Held by Freodica 1. Provide pipe caps for those abandoned floor drains. 2. Provide drinking fountain. | |||
| BLD | HOLD | 03/24/2011 | 03/24/2011 |
| Note: Held by J. Hindman. provide detail for the 8'x8' door opening. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 06/20/2011 |
| REVISION | ¤40.00 | 06/20/2011 |
| REVISION | ¤40.00 | 06/20/2011 |
| SITE PLAN 20 | ¤20.00 | 05/02/2011 |
| SURCHARGE FS 533.721 | ¤2.24 | 05/02/2011 |
| SURCHARGE - FS 468.631 | ¤2.24 | 05/02/2011 |
| ADMIN COMMERCIAL | ¤60.00 | 05/02/2011 |
| BUILDING DISCOUNT 100% | (¤1,335.38) | 05/02/2011 |
| ELECTRIC FEE | ¤135.00 | 05/02/2011 |
| FIRE PLANS REVIEW | ¤25.00 | 05/02/2011 |
| MECHANICAL FEE | ¤135.00 | 05/02/2011 |
| PERMIT FEE | ¤875.00 | 05/02/2011 |
| PLAN CHECK FEE | ¤143.75 | 05/02/2011 |
| PLUMBING FEE | ¤135.00 | 05/02/2011 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤317.85 |