I want to search for...

Permit #2011040575

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7016-00100-0320
Block: 10
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: 407-871-2020
Location Address: 4 CHER CT
Type: PO - POOL
Issue Date: 05/16/2011
NOC: RECORDED
Applicant name: JOHN NICHOLAS WATTS
Owner: LEIGHTON, PAUL

Address

4 CHER COURT

PALM COAST, FL 32137

Lot: 32
Contracted Stated Job Value: ¤28,753.00
Job Description: POOL W/DECK, 4 FT. ALUM. WROUGHT IRON FENCE AND STAIRS
Type: CN

Contractor

ALL SEASONS POOL SERVICE INC
Status Location Address State License Number Phone Fax
ACTIVE

185 E AIRPORT BLVD

GENEVA , FL 32732

CPC023576 (Exp: 08/31/2026) 407-871-2020 407-321-5404

Sub Contractors

BRIAN KEITH MILLER
Status Location Address State License Number Phone Fax
INACTIVE

685 S RONALD REAGAN BLVD

LONGWOOD, FL 32750

EC13001686 (Exp: 08/31/2026) (386)668-4222 (386)668-8222

Inspection History

Type Request Date Result Inspector
POOL FINAL 12/09/2011 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
POOL FINAL 12/07/2011 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 12/7/2011 1:04:40 PM VACUME GUAGE NOT INSTALLED ON POOL PUMP-COULD NOT VERIFY TDH PER CHART.NOT MENTIONED AT PREVIOUS INSPECTION BECAUSE NO PLANS WERE AVAILABLE TO HIM AT THAT TIME.
ROW DAMAGE 11/02/2011 CANCELLED BY APPLICANT AIRS WEB
ROW DAMAGE 11/01/2011 APPROVED KHOWELL
Note: THIS IS A REINSPECTION
POOL FINAL 10/12/2011 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 10/12/2011 10:53:19 AM RAILING NOT BONDED CARRIED OVER FROM ELECTRIC INSPECTION,NO PLANS ON JOB FOR PROPER INSPECTION.ITEMS FROM R.O.W. NOT CORRECTED.NEED TO CORRECT ALL.
U -UTILITY RESIDENTIAL FINAL 10/11/2011 APPROVED TSCHWEERS
ROW DAMAGE 10/11/2011 Disapproved -FEE REQUIRED KHOWELL
Note: 1. Repair The Damaged Asphalt Marked With Paint. 2. Remove Concrete And Road Base From R.O.W. Marked With Paint And Sod. 3. Seed And Straw All Disturbed Areas Outside The R.O.W. On Vacant Lot. Kevin Howell Photos Taken
FINAL SURVEY (OFFICE USE ONLY) 10/06/2011 APPROVED JHINDMAN
POOL FINAL 09/23/2011 CANCELLED BY APPLICANT AIRS WEB
ELECTRIC AND ALARM 07/14/2011 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 7/14/2011 2:31:46 PM NEED TO BOND RAILING,CHECK ON FINAL
POOL DECK 07/07/2011 APPROVED CMINI
FOOTER 06/28/2011 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 6/28/2011 3:12:50 PM OK TO SHOOT RETAINING WALL-PROVIDE STAIR DETAIL TO BE INSTALLED AND CALL FOR INSPECTION
STEEL AND GROUND 06/24/2011 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/24/2011 3:30:40 PM NEED TO HAVE SILT FENCE INSTALLED ALONG SEA WALL BEFORE ANY MORE WORK IS TO BE PERFORMED,DIRT IS ALREADY FALLING INTO CANAL..... THIS IS NOT A STEEL IN GROUND INSPECTION IT IS A FOOTER INSPECTION... NEED DETAIL FOR STEPS..... NEED TO FORM TO THE CORRECT HIEGHT OF FOOTER ,NEED CLEARANCE AROUND STEEL THAT IS EMBEDDED INTO DIRT,NEED TO CLEAN OUT FOOTER THAT IS CAVED IN..BOTTOM FOOTER NOT CORRECT WIDTH FOOTER DOES NOT MATCH PLAN LAYOUT...
STEEL AND GROUND 06/07/2011 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/06/2011 10/06/2011
Note: Released By: JHINDMAN
ZON COMPLETE 10/06/2011 10/06/2011
Note: Released By: JHINDMAN
ZON HOLD 09/19/2011 09/19/2011
Note: Held By: JHINDMAN final survey The survey shows additional concrete was poured next to the pool. revise the site plan to reflect this change.
SW1 HOLD 09/16/2011 09/19/2011
Note: Held By: JHINDMAN final survey The survey shows additional concrete was poured. revise site plan to reflect this change.
BLD COMPLETE 07/01/2011 07/01/2011
Note: Released by J. Hindman
ZON COMPLETE 07/01/2011 07/01/2011
Note: Released by Drameriz
ZON HOLD 06/29/2011 06/29/2011
Note: Provide an updated site plan to show the location, setbacks and dimensions of the proposed stairs.
SW1 COMPLETE 06/29/2011 06/29/2011
Note: released by J. Hindman
BLD HOLD 06/29/2011 06/29/2011
Note: Held by J. Hindman 1. provide stair riser details
ZON COMPLETE 06/29/2011 06/29/2011
Note: Released By: DRAMIREZ
BLD COMPLETE 06/29/2011 06/29/2011
Note: Released By: JHINDMAN
ZON COMPLETE 05/13/2011 05/13/2011
ZON HOLD 05/11/2011 05/11/2011
Note: Provide the new square footage of the deck on the site plan. Square footage on site plan was not updated after setback changes.
SW1 COMPLETE 05/02/2011 05/03/2011
Note: Released by Freodica
ZON HOLD 05/02/2011 05/03/2011
Note: KDavis- Minimum rear setback for structures in the SFR 2 zoning district is 6.5 feet. Submitted site plan illustrates proposed pool located 5 feet from rear property line.
BLD COMPLETE 05/02/2011 05/03/2011
Note: Released by Freodica
SW1 COMPLETE 04/21/2011 04/21/2011
Note: Released by JJoseph
ZON HOLD 04/21/2011 04/21/2011
Note: DRamirez Provide the following information on the site plan- a. Setbacks for the concrete deck to the rear property line. b. Location of the equipment pad to include dimensions and setback. c. Note landscaping shrubs will be required on the rear of fence facing the intercoastal waterway.
BLD HOLD 04/21/2011 04/21/2011
Note: Held by Freodica Provide site specific detail for retaining wall. Pool plan shows 7 ft tall but masterpile drawing shows maximum 4 ft tall.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 12/08/2011
REINSPECTION FEE ¤40.00 10/31/2011
REINSPECTION FEE ¤40.00 10/31/2011
REVISION ¤40.00 07/07/2011
REINSPECTION FEE ¤40.00 07/07/2011
SITE PLAN 20 ¤20.00 05/16/2011
SURCHARGE FS 533.721 ¤2.00 05/16/2011
SURCHARGE - FS 468.631 ¤2.00 05/16/2011
BUILDING DISCOUNT 100% (¤198.00) 05/16/2011
PERMIT FEE ¤260.00 05/16/2011
PLAN CHECK FEE ¤40.00 05/16/2011
Fees Total Due: ¤0.00 Total Paid: ¤326.00