Permit #2011050416

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7009-00210-0220
CONDITIONED SPACE: 418 sqft
OPENED PORCH (WITH ROOF) : 54 sqft
Total Square Footage: 472 sqft
Block: 21
Subdivision: 2208 - SECTION 9-FLORIDA PARK
Job Phone: 386-586-7093
Location Address: 60 FALLEN OAK LN
Type: BA - BUILDING ADDITION
Issue Date: 06/16/2011
NOC: RECORDED
Applicant name: ERIC GLENN SAMUELSON
Owner: GREEN CYNTHIA & HOWELL G H&W & JOEL O GREEN (ASM)

Address

60 FALLEN OAK LANE

PALM COAST, FL 32137

Lot: 22
Contracted Stated Job Value: ¤38,000.00
Job Description: NEW ROOM ADDITION W/BATH & CONSTRUCT NEW COVERED ENTRANCE ADDITION
Type: CN

Contractor

VIKING CONTRACTORS
Status Location Address State License Number Phone Fax
CANCEL

597 JOHN ANDERSON HIGHWAY

PALM COAST, FL 32164

CBC1257381 (Exp: 08/31/2014) 386-586-7093 386-586-6146

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address State License Number Phone Fax
CANCEL

55 BARRISTER LN

PALM COAST, FL 32137

ER13013466 (Exp: 08/31/2014) 386-586-9144 (386)246-6305
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
DAVID L MILLER
Status Location Address State License Number Phone
CANCEL

170 OLD MOODY BLVD

BUNNELL, FL 32110

CFC1425948 (Exp: 08/31/2022) (386) 439-2169
KENNETH MARTIN REED
Status Location Address State License Number Phone Fax
ACTIVE

83 LANCELOT DRIVE

BUNNELL , FL 32110

CCC1328712 (Exp: 08/31/2026) 386-446-3100 386-445-6074

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/11/2013 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 01/09/2013 APPROVED DROCKWELL
STORMWATER FINAL 11/30/2012 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROW DAMAGE 11/30/2012 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
FOUND SURVEY APPROVED (OFFICE) 10/17/2012 APPROVED JMCGOWEN
STORMWATER FINAL 10/04/2012 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 10/4/2012 2:50:52 PM COVER ALL LOOSE SOILS WITH SOD TO SWALE.CURRENTLY SOIL IS COVERING DRIVWAY AND ENCROACHING INTO SWALE
ROW DAMAGE 10/04/2012 Disapproved -FEE REQUIRED GLALIMA
Note: PICTURES . NEED TO HAVE ALL EROSION UNDER CONTROL . SWEEP ALL SAND AND FILL OFF DRIVEWAY . REPAIR ALL RUTS IN SWALE TO RIGHT ON VACANT LOT . ADD SOD IF NEEDED AT SIDE OF DRIVEWAY TO STOP EROSION . WHEN PLACING SOD IT MUST BE AT SAME ELEVATION AS OTHER. CALL GARY IF NEEDED 986 - 4767
PROJECT STATUS (OFFICE USE) 03/30/2012 Disapproved - NO FEE DROCKWELL
Note: Inspection Resulted at 3/30/2012 12:36:45 PM WORK APPEARS COMPLETE FROM EXTERIOR.....
PLUMBING 1ST ROUGH UNDERGROUND 10/20/2011 APPROVED DROCKWELL
INSULATION 09/28/2011 APPROVED DROCKWELL
ALL ROUGH 09/20/2011 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 09/19/2011 APPROVED CMINI
ALL ROUGH 09/19/2011 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
ALL ROUGH 09/15/2011 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 9/15/2011 12:21:50 PM FIREBLOCK BATH WALL AT EXISTING HOUSE/WIRE EXHAUST FAN/SUPPORT EXHAUSTDUCT AT MID-POINT W/STRAP/NEED WATER TEST ON SANITARY LINES/PROVIDE APPROVE A/C PLAN SHOWING SUPPLY AND RETURN LINES
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/17/2011 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/11/2011 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION REQUESTED BY CONTRACTOR Inspection Resulted at 8/11/2011 3:08:27 PM NEED TO COMPLETE GABLE END BLOCKING PER PLAN.....CANNOT NAIL STRAPS INTO OTHER STRAPS PER SIMPSON...ANCHORS INTO WALL PLATE GOING INTO EXISTING HOUSE NOT TO PLAN...AT SAME PLATE NEED TO CORRECT STRAP THAT HAS SLACK IN IT..NEED TO COMPLETE FURRING OUT ON INTERIOR WALL AS PER PLAN.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/04/2011 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 8/4/2011 12:28:40 PM ENTRY GABLE END NOT BLOCKED TO PLAN/BEAM ANCHORING INTO EXISTING WALL HAS NO DETAIL/INSTALL TRUSS CLIPS PROPERLY AT RAFTER TIE IN TO SLEEPER/FURNISH DETAIL FOR ANCHORING NEW TRUSSES TO EXISTING EXTERIOR WALL REAR ADDITION/VOLUME CEILING IN REAR ADDITION ENDS AT A FRAME WALL THAT IS NOT BALLON FRAMED-SUGGEST ARCHITECT VISIT SITE TO DETERMINE DEGREE OF PROBLEM/COMPLETE NAILING AT EXTERIOR SHEATHING/ROOF METALS INSTALLED BY THIS INSPECTION
MONOLITHIC SLAB 07/06/2011 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 07/05/2011 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 7/5/2011 12:41:48 PM NO FOOTING DETAIL ON SITE/DRILLED DOWELS ARE TO BE 2FT ON CENTER PER PLAN

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/17/2012 10/17/2012
Note: Released By: JMCGOWEN FOUNDATION SURVEY
ZON COMPLETE 10/17/2012 10/17/2012
Note: Released By: JMCGOWEN FOUNDATION SURVEY
BLD COMPLETE 08/16/2011 08/16/2011
Note: Released By: JMCGOWEN frame to block connection
BLD COMPLETE 08/09/2011 08/10/2011
Note: released by J. Hindman
MECH COMPLETE 06/14/2011 06/14/2011
ZON COMPLETE 06/06/2011 06/07/2011
Note: Released by KDavis
PLUM COMPLETE 06/06/2011 06/06/2011
BLD COMPLETE 06/06/2011 06/06/2011
Note: released by J. Hindman
MECH HOLD 06/06/2011 06/06/2011
Note: Provide total square foot of house and total BTU of existing A/C unit and give us a determination if existing unit can handle the added load.
ZON HOLD 05/18/2011 05/19/2011
Note: The site plan submitted does not match the site plan on file for the house. The site plan on file has a 10x22 concrete porch situated on the rear middle portion of the house; but the site plan submitted has a larger porch that extends further out then 10'. It also appears that a concrete slab was poured on the rear right side of the house with no permit on file. This permit application must include hatched out areas not only for the new extension but also square footages for the extension to the previously approved 10x22 slab and the slab located on the rear right side of house.
PLUM HOLD 05/18/2011 05/19/2011
Note: Held by Freodica 1. Provide sanitary riser diagram and DWV material specification.
SW1 COMPLETE 05/18/2011 05/19/2011
Note: Released by JJoseph
ELEC COMPLETE 05/18/2011 05/19/2011
Note: released by J. Hindman
MECH HOLD 05/18/2011 05/19/2011
Note: Held by Freodica 1. Provide hvac duct system layout for the additional rooms. 2. Energy calculations shows only for the additional rooms but it does not show the capacity of the unit to be used. If the existing unit would be used, submit energy calculation based on the whole house to determine if the existing unit capacity can handle the existing and the additional load.
BLD HOLD 05/18/2011 05/19/2011
Note: Held by J. Hindman 1. provide anchorage detail for shutters at egress window on CMU wall.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/17/2012
REINSPECTION FEE ¤40.00 10/17/2012
EXTENSION ¤40.00 10/04/2012
REINSPECTION FEE ¤40.00 04/12/2012
REINSPECTION FEE ¤40.00 04/12/2012
REINSPECTION FEE ¤40.00 04/12/2012
REINSPECTION FEE ¤40.00 04/12/2012
REVISION ¤40.00 04/12/2012
REVISION ¤40.00 04/12/2012
EXTENSION ¤40.00 04/12/2012
BUILDING DISCOUNT 100% (¤324.90) 06/16/2011
ELECTRIC FEE ¤174.00 06/16/2011
SITE PLAN 20 ¤20.00 06/16/2011
SURCHARGE FS 533.721 ¤2.00 06/16/2011
SURCHARGE - FS 468.631 ¤2.00 06/16/2011
REMODEL/ADDITION/ACCES INSPECT ¤80.00 06/16/2011
MECHANICAL FEE ¤174.00 06/16/2011
PERMIT FEE ¤200.00 06/16/2011
PLAN CHECK FEE ¤80.00 06/16/2011
PLUMBING FEE ¤174.00 06/16/2011
Fees Total Due: ¤0.00 Total Paid: ¤981.10