Permit #2011080512

Permit Details

Status: COED

Parcel Id: 07-11-31-7002-00030-0100
Block: 00030
Subdivision: 2218 - SECTION 2-FLORIDA PARK
Job Phone: 386-447-1402
Location Address: 7 FLORIDA PARK DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 09/12/2011
NOC: RECORDED
Applicant name: RONALD ERIC PHILLIPS
Owner: GARDNER THORNHILL LLC

Address

PO BOX 351429

PALM COAST, FL 32135

Lot: 0100
Contracted Stated Job Value: ¤4,000.00
Job Description: "STYLES SALON"- CONVERT COMMERICIAL SPACE INTO HAIR SALON
Type: CN

Contractor

PHILLIPS COASTAL CONSTRUCTION, INC
Status Location Address State License Number Phone
CANCEL

58 BUTTERFIELD DRIVE

PALM COAST, FL 32137

CGC1506412 (Exp: 08/31/2024) 386-447-1402

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
THOMAS P MCGUIRE JR
Status Location Address State License Number Phone Fax
ACTIVE

935 ALEXANDER AVE

PORT ORANGE, FL 32119

CAC012263 (Exp: 08/31/2026) 386-767-3900 386-761-1205

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 10/11/2011 APPROVED CMINI
ABOVE CEILING 10/11/2011 APPROVED LHITES
Note: THIS IS A REINSPECTION
BUILDING FINAL 10/11/2011 FINAL APPROVED CMINI
FIRE FINAL 10/11/2011 APPROVED LHITES
U - UTILITY COMMERCIAL FINAL 10/11/2011 APPROVED DSPENCER
PLUMBING 2ND ROUGH 09/27/2011 APPROVED - AS NOTED JMCGOWEN
Note: provide fire wraps on pipes penetrating fire rated floor make sure it gets inspected
ABOVE CEILING 09/22/2011 Disapproved -FEE REQUIRED LHITES
Note: Inspection Resulted at 9/22/2011 12:27:27 PM 1. TYPE NM CABLE IS NOT PERMITTED IN SUSPENDEDOR DROPPED CEILINGS. 334.12 (A)(2) 2008 NEC
PLUMBING 1ST ROUGH 09/22/2011 APPROVED CMINI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH 09/21/2011 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 9/21/2011 2:48:52 PM NEED TO HAVE 5`` OF HEAD PRESSURE ON DRAINAGE SYSTEM

Review History

Department Status Date In Date Out
MECH COMPLETE 09/09/2011 09/09/2011
Note: Released by Freodica Exhaust fan is not required as pedicure room will be changed to hair color room per Building official.
ZON COMPLETE 09/09/2011 09/09/2011
Note: Released by jgonzalez use approved
ELEC COMPLETE 09/09/2011 09/09/2011
Note: exhaust fan eliminated and pedicure room change to hair coloring room
ZON HOLD 09/01/2011 09/01/2011
Note: DRamirez Provide a site plan depicting the building with the location of units to be converted. The plan submitted is a signed and sealed plan that cannot be altered.
MECH HOLD 09/01/2011 09/01/2011
Note: Provide outdoor air intake calculations
ELEC HOLD 09/01/2011 09/01/2011
Note: Provide exhaust fan load for nail area and add to panel schedule
BLD COMPLETE 09/01/2011 09/01/2011
FI1 COMPLETE 09/01/2011 09/01/2011
PLUM COMPLETE 09/01/2011 09/01/2011
UD1 COMPLETE 08/23/2011 08/25/2011
ZON HOLD 08/23/2011 08/23/2011
Note: DRamirez Provide a site plan depicting location of units to be converted.
ELEC HOLD 08/23/2011 08/23/2011
Note: Provide exhaust fan load for nail area
FI1 HOLD 08/23/2011 08/23/2011
Note: Held by J. Hindman 1. provide an exhast fan for the pedicure area and block off any returns in that room. 2. provide mechanical subcontractor.
PLUM HOLD 08/23/2011 08/23/2011
Note: Held By: FREODICA 1. Provide domestic water (hot and cold) riser diagram including pipe sizes. 2. For clarity, provide pipe sizes on sanitary riser diagram where (4) sinks were wet vented. If the plumbing size note shown on plan would be used, the vent size for wet vented sinks could exceed the drainage fixture unit load per FPC 2007 Table 909.3. 3. Provide material specifications for DWV, hot and cold water piping. 4. Provide water heater specification.
SW1 COMPLETE 08/23/2011 09/01/2011
Note: No Site Plan Provided for Review
BLD HOLD 08/23/2011 08/23/2011
Note: Held by J. Hindman 1. provide for ADA turning radius in restroom.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/07/2011
SITE PLAN 20 ¤20.00 09/12/2011
SURCHARGE FS 533.721 ¤2.00 09/12/2011
SURCHARGE - FS 468.631 ¤2.00 09/12/2011
ADMIN COMMERCIAL ¤60.00 09/12/2011
BUILDING DISCOUNT 100% (¤402.48) 09/12/2011
ELECTRIC FEE ¤62.40 09/12/2011
FIRE PLANS REVIEW ¤25.00 09/12/2011
MECHANICAL FEE ¤62.40 09/12/2011
PERMIT FEE ¤100.00 09/12/2011
PLAN CHECK FEE ¤100.00 09/12/2011
PLUMBING FEE ¤62.40 09/12/2011
Fees Total Due: ¤0.00 Total Paid: ¤133.72