Permit #2011080512
Permit Details
Status: COED
| Parcel Id: 07-11-31-7002-00030-0100 |
| Block: 00030 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: 386-447-1402 |
| Location Address: 7 FLORIDA PARK DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 09/12/2011 |
| NOC: RECORDED |
| Applicant name: RONALD ERIC PHILLIPS |
| Owner: GARDNER THORNHILL LLC |
|
Address PO BOX 351429 PALM COAST, FL 32135 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤4,000.00 |
| Job Description: "STYLES SALON"- CONVERT COMMERICIAL SPACE INTO HAIR SALON |
| Type: CN |
Contractor
PHILLIPS COASTAL CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone |
| CANCEL |
58 BUTTERFIELD DRIVE PALM COAST, FL 32137 |
CGC1506412 (Exp: 08/31/2024) | 386-447-1402 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
THOMAS P MCGUIRE JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
935 ALEXANDER AVE PORT ORANGE, FL 32119 |
CAC012263 (Exp: 08/31/2026) | 386-767-3900 | 386-761-1205 |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING FINAL | 10/11/2011 | APPROVED | CMINI |
| ABOVE CEILING | 10/11/2011 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| BUILDING FINAL | 10/11/2011 | FINAL APPROVED | CMINI |
| FIRE FINAL | 10/11/2011 | APPROVED | LHITES |
| U - UTILITY COMMERCIAL FINAL | 10/11/2011 | APPROVED | DSPENCER |
| PLUMBING 2ND ROUGH | 09/27/2011 | APPROVED - AS NOTED | JMCGOWEN |
| Note: provide fire wraps on pipes penetrating fire rated floor make sure it gets inspected | |||
| ABOVE CEILING | 09/22/2011 | Disapproved -FEE REQUIRED | LHITES |
| Note: Inspection Resulted at 9/22/2011 12:27:27 PM 1. TYPE NM CABLE IS NOT PERMITTED IN SUSPENDEDOR DROPPED CEILINGS. 334.12 (A)(2) 2008 NEC | |||
| PLUMBING 1ST ROUGH | 09/22/2011 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH | 09/21/2011 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 9/21/2011 2:48:52 PM NEED TO HAVE 5`` OF HEAD PRESSURE ON DRAINAGE SYSTEM |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 09/09/2011 | 09/09/2011 |
| Note: Released by Freodica Exhaust fan is not required as pedicure room will be changed to hair color room per Building official. | |||
| ZON | COMPLETE | 09/09/2011 | 09/09/2011 |
| Note: Released by jgonzalez use approved | |||
| ELEC | COMPLETE | 09/09/2011 | 09/09/2011 |
| Note: exhaust fan eliminated and pedicure room change to hair coloring room | |||
| ZON | HOLD | 09/01/2011 | 09/01/2011 |
| Note: DRamirez Provide a site plan depicting the building with the location of units to be converted. The plan submitted is a signed and sealed plan that cannot be altered. | |||
| MECH | HOLD | 09/01/2011 | 09/01/2011 |
| Note: Provide outdoor air intake calculations | |||
| ELEC | HOLD | 09/01/2011 | 09/01/2011 |
| Note: Provide exhaust fan load for nail area and add to panel schedule | |||
| BLD | COMPLETE | 09/01/2011 | 09/01/2011 |
| FI1 | COMPLETE | 09/01/2011 | 09/01/2011 |
| PLUM | COMPLETE | 09/01/2011 | 09/01/2011 |
| UD1 | COMPLETE | 08/23/2011 | 08/25/2011 |
| ZON | HOLD | 08/23/2011 | 08/23/2011 |
| Note: DRamirez Provide a site plan depicting location of units to be converted. | |||
| ELEC | HOLD | 08/23/2011 | 08/23/2011 |
| Note: Provide exhaust fan load for nail area | |||
| FI1 | HOLD | 08/23/2011 | 08/23/2011 |
| Note: Held by J. Hindman 1. provide an exhast fan for the pedicure area and block off any returns in that room. 2. provide mechanical subcontractor. | |||
| PLUM | HOLD | 08/23/2011 | 08/23/2011 |
| Note: Held By: FREODICA 1. Provide domestic water (hot and cold) riser diagram including pipe sizes. 2. For clarity, provide pipe sizes on sanitary riser diagram where (4) sinks were wet vented. If the plumbing size note shown on plan would be used, the vent size for wet vented sinks could exceed the drainage fixture unit load per FPC 2007 Table 909.3. 3. Provide material specifications for DWV, hot and cold water piping. 4. Provide water heater specification. | |||
| SW1 | COMPLETE | 08/23/2011 | 09/01/2011 |
| Note: No Site Plan Provided for Review | |||
| BLD | HOLD | 08/23/2011 | 08/23/2011 |
| Note: Held by J. Hindman 1. provide for ADA turning radius in restroom. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 10/07/2011 |
| SITE PLAN 20 | ¤20.00 | 09/12/2011 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/12/2011 |
| SURCHARGE - FS 468.631 | ¤2.00 | 09/12/2011 |
| ADMIN COMMERCIAL | ¤60.00 | 09/12/2011 |
| BUILDING DISCOUNT 100% | (¤402.48) | 09/12/2011 |
| ELECTRIC FEE | ¤62.40 | 09/12/2011 |
| FIRE PLANS REVIEW | ¤25.00 | 09/12/2011 |
| MECHANICAL FEE | ¤62.40 | 09/12/2011 |
| PERMIT FEE | ¤100.00 | 09/12/2011 |
| PLAN CHECK FEE | ¤100.00 | 09/12/2011 |
| PLUMBING FEE | ¤62.40 | 09/12/2011 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤133.72 |