I want to search for...
Permit #2011110239
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7013-00030-0040 |
| ENCLOSE EXISTING PORCH TO LIVING : 276 sqft |
| PATIO/DECK (NO ROOF) : 120 sqft |
| Total Square Footage: 396 sqft |
| Block: 00030 |
| Subdivision: 2192 - SECTION 13-BELLE TERRE |
| Job Phone: (386) 446-3615 |
| Location Address: 41 BRACKEN LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 11/23/2011 |
| NOC: RECORDED |
| Applicant name: RICHARD W HAUSEN |
| Owner: KILTY KEITH & CRISTINA LOYOLA- KILTY H&W |
|
Address 6032 THATCHER DRIVE DUBLIN, OH 43017 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤15,000.00 |
| Job Description: BUILDING ADDITION & 12 X 10 PATIO |
| Type: CN |
Contractor
HAUSEN PROPERTIES INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 351868 Palm Coast, FL 32135 |
RG0029505 (Exp: 08/31/2025) | (386) 446-3615 | 386-446-3615 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
55 BARRISTER LN PALM COAST, FL 32137 |
ER13013466 (Exp: 08/31/2014) | 386-586-9144 | (386)246-6305 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/20/2012 | FINAL APPROVED | DROCKWELL |
| FINAL SURVEY (OFFICE USE ONLY) | 04/16/2012 | APPROVED | JHINDMAN |
| ROW DAMAGE | 04/13/2012 | APPROVED | KHOWELL |
| U -UTILITY RESIDENTIAL FINAL | 04/13/2012 | APPROVED | KKING |
| INSULATION | 01/25/2012 | APPROVED | DROCKWELL |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/20/2012 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/20/2012 | APPROVED | DROCKWELL |
| Note: requested by contractor | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/28/2011 | Disapproved -FEE REQUIRED | LHITES |
| Note: Inspection Resulted at 12/28/2011 3:28:50 PM 1. NEED APPROVAL FROM TRUSS ENGINEER ON SUPPORT FOR EXISTING HOME SIDE OF TRUSS, DOES NOT MATCH ENGINEERING. 2. REVISE DRAWING TO SHOW SUPPORT THAT HAS BEEN BUILT FOR TRUSSES. 3. MUST REPLACE H 2.5 THAT ARE BENT. 4. MUST HAVE SEPERATION FROM BLOCK TO WOOD THAT IS NOT PRESSURE TREATED. | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/27/2011 | APPROVED | JMCGOWEN |
| MONOLITHIC SLAB | 12/01/2011 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/1/2011 3:26:27 PM REMOVE VISQUEEN FROM EXISTING SLAB BEFORE POUR-CONCRETE WILL NOT BOND TO PLASTIC.PLANS DO NOT SHOW PLASTIC OVER EXISTING SLAB. | |||
| MONOLITHIC SLAB | 11/29/2011 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 11/29/2011 11:54:14 AM PLANS SHOW A 4IN CONCRETE SLAB FOR ADDITION.THERE IS NO MENTION OF POUR OVER EXISTING CONCRETE SLAB.NEED REVISION STAMPED BY ENGINEER AND APPROVED BY CITY BUILDING DEPT SHOWING ACTUAL CONDITIONS PRIOR TO POUR. |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 04/16/2012 | 04/16/2012 |
| Note: Released By: JHINDMAN final survey | |||
| SW1 | COMPLETE | 04/16/2012 | 04/16/2012 |
| Note: Released By: JHINDMAN final survey | |||
| BLD | COMPLETE | 02/09/2012 | 02/09/2012 |
| PLUM | COMPLETE | 02/07/2012 | 02/07/2012 |
| Note: n/a | |||
| SW1 | COMPLETE | 02/07/2012 | 02/07/2012 |
| Note: n/a | |||
| MECH | COMPLETE | 02/07/2012 | 02/07/2012 |
| Note: n/a | |||
| ELEC | COMPLETE | 02/07/2012 | 02/07/2012 |
| BLD | COMPLETE | 02/07/2012 | 02/07/2012 |
| BLD | HOLD | 02/01/2012 | 02/01/2012 |
| Note: Provide Florida product approval and installation schedules | |||
| ZON | COMPLETE | 02/01/2012 | 02/06/2012 |
| ELEC | COMPLETE | 01/11/2012 | 01/11/2012 |
| BLD | COMPLETE | 01/11/2012 | 01/11/2012 |
| BLD | COMPLETE | 11/30/2011 | 11/30/2011 |
| BLD | COMPLETE | 11/22/2011 | 11/22/2011 |
| BLD | HOLD | 11/21/2011 | 11/21/2011 |
| Note: Held by Freodica 1. Provide Florida Product Approval for windows as previously requested. 2. Provide building design informations as previously requested regarding code year, wind load, exposure and category. | |||
| MECH | COMPLETE | 11/21/2011 | 11/21/2011 |
| Note: Released by Freodica | |||
| SW1 | COMPLETE | 11/14/2011 | 11/14/2011 |
| ZON | COMPLETE | 11/14/2011 | 11/15/2011 |
| MECH | HOLD | 11/14/2011 | 11/14/2011 |
| Note: The HVAC drawing will need the contractor’s license number and signature provide HVAC performance evaluation to insure existing equipment can handle the added load | |||
| PLUM | COMPLETE | 11/14/2011 | 11/14/2011 |
| Note: no plumbing on this permit | |||
| BLD | HOLD | 11/14/2011 | 11/14/2011 |
| Note: Provide signed and sealed roof plan with connector schedule, provide Florida product approval number and schedules for doors and windows, provide code year, wind load designed to, and indicate exposure | |||
| ELEC | COMPLETE | 11/14/2011 | 11/14/2011 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 04/02/2012 |
| REVISION | ¤40.00 | 04/02/2012 |
| REINSPECTION FEE | ¤40.00 | 04/02/2012 |
| REINSPECTION FEE | ¤40.00 | 11/30/2011 |
| REVISION | ¤40.00 | 11/30/2011 |
| SITE PLAN 20 | ¤20.00 | 11/23/2011 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/23/2011 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/23/2011 |
| BUILDING DISCOUNT 100% | (¤221.76) | 11/23/2011 |
| ELECTRIC FEE | ¤73.20 | 11/23/2011 |
| MECHANICAL FEE | ¤73.20 | 11/23/2011 |
| PERMIT FEE | ¤100.00 | 11/23/2011 |
| PLAN CHECK FEE | ¤40.00 | 11/23/2011 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 11/23/2011 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤328.64 |