Permit #2012010035
Permit Details
Status: FINAL
| Parcel Id: 48-11-31-1710-00000-0140 |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: (386)445-4747 |
| Location Address: 204 WILLOW OAK WAY |
| Type: PO - POOL |
| Issue Date: 01/13/2012 |
| NOC: RECORDED |
| Applicant name: LAWRENCE PATRICK VANDIVIER |
| Owner: ARH MODELS LLC |
|
Address 13922 58TH STREET NORTH CLEARWATER, FL 33760 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤30,000.00 |
| Job Description: POOL W/SPA & TRELLIS, GAS FIREPLACE & ALUMINUM FENCE |
| Type: CN |
Contractor
COUNTRY CLUB POOLS & SPAS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
4444 N. OCEANSHORE BLVD PALM COAST, FL 32137 |
CPC057239 (Exp: 08/31/2024) | (386)445-4747 | (386)445-5955 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
317 RIO PINR DR Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2026) | 386-233-1553 | 386-673-5994 |
KEN DEPRINZIO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
325 WALKER STREET HOLLY HILL, FL 32117 |
11351 (Exp: 08/31/2026) | 386-672-8494 | 386-673-7856 |
WILLIAM VALENTINE GROFF
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
4440 N OCEANSHORE BLVD SUITE 101 PALM COAST, FL 32137 |
CBC1256262 (Exp: 08/31/2020) | 386-445-4747 | 386-445-5955 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 07/17/2012 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| POOL FINAL | 06/29/2012 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/29/2012 2:50:08 PM VIOLATIONS CORRECTED-HOWEVER-CALCULATED TDH IS 39.5 ACTUAL TDH ACCORDING TO GUAGES-IS 34.2..ACTUAL TDH MUST BE EQUQL TO OR HIGHER THAN CALCULATEDTDH. | |||
| POOL FINAL | 06/06/2012 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 6/6/2012 2:51:05 PM NEED TO VERIFY BURIAL DEPTH FOR GAS LINE.NEED TO HAVE FINAL SURVEY ,NEED TO HAVE POP OFF RELIEF VALVE FOR POOL HEATER.NEED REVISION FOR FOOTER THAT WAS PASS NOTED ON POOL DECK | |||
| GAS FINAL | 06/06/2012 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/6/2012 2:51:05 PM NEED TO VERIFY BURIAL DEPTH AND FINAL SURVEY FOR LOCATION NEEDED CHECK ON POOL FINAL | |||
| GAS ROUGH | 06/06/2012 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/6/2012 2:51:04 PM NEED TO VERIFY BURIAL DEPTH..CHECK ON POOL FINAL | |||
| ROW DAMAGE | 06/06/2012 | APPROVED | KHOWELL |
| Note: I Was Not At Work On June 6, 2012 Kevin Howell | |||
| U -UTILITY RESIDENTIAL FINAL | 06/06/2012 | APPROVED | DSPENCER |
| Note: requested by contractor | |||
| ELECTRIC AND ALARM | 02/29/2012 | APPROVED | CMINI |
| Note: REQUESTED BY CONTRACTOR | |||
| FINAL SURVEY (OFFICE USE ONLY) | 02/22/2012 | APPROVED | JHINDMAN |
| POOL DECK | 02/09/2012 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION REQUESTED BY CONTRACTOR | |||
| POOL DECK | 02/08/2012 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 2/8/2012 11:31:43 AM POOL DECK NOT READY FOR INSPECTION | |||
| COLUMN INSPECTION | 02/08/2012 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 2/8/2012 11:31:42 AM COLUMNS GOOD STILL WAITING FOR FOOTING DETAIL FOR FIREPLACE | |||
| FOOTER | 02/02/2012 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 2/2/2012 1:13:55 PM 4 COLUMN FOOTERS APPROVED NEED DETAIL REVISION FOR FIREPLACE FOOTER. | |||
| STEEL AND GROUND | 01/26/2012 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/06/2012 | 03/06/2012 |
| ZON | COMPLETE | 02/22/2012 | 02/22/2012 |
| Note: Released By: JHINDMAN final survey | |||
| SW1 | COMPLETE | 02/22/2012 | 02/22/2012 |
| Note: Released By: JHINDMAN final survey | |||
| BLD | COMPLETE | 01/11/2012 | 01/11/2012 |
| Note: Released by Freodica | |||
| ZON | COMPLETE | 01/10/2012 | 01/10/2012 |
| BLD | HOLD | 01/10/2012 | 01/10/2012 |
| Note: Held by Freodica Same hold comment for gas. | |||
| SW1 | COMPLETE | 01/10/2012 | 01/10/2012 |
| Note: Released by JJoseph already reviewed | |||
| BLD | HOLD | 01/10/2012 | 01/10/2012 |
| Note: Held by Freodica 1. Submitted gas riser diagram shall include gas pipe size, material, load in Btu/hr, source of connection (where it is tied into) and gas contractor license number indicated on plan or company letter head. | |||
| ZON | HOLD | 01/10/2012 | 01/10/2012 |
| Note: Provide a callout of the location of trellis with height on the site plan. Provide dimensions of the pool on the site plan. Remove pool by others from site plan. | |||
| BLD | HOLD | 01/03/2012 | 01/03/2012 |
| Note: Provide contractor that is building the structure on pool deck, provide signed and sealed drawings for the fireplace/trellis structure, provide gas riser detail, tank size and location, clarify what slab/footing detail is to be used. | |||
| SW1 | COMPLETE | 01/03/2012 | 01/04/2012 |
| Note: Released by JJoseph | |||
| ZON | HOLD | 01/03/2012 | 01/04/2012 |
| Note: 1. Provide Homeowner Association approval letter. 2. On site plan provide the following- a. Type of aluminum fencing to be installed. b. Height of fence. c. Location, dimension and setback of the equipment pad. d. Trellis location with height. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/09/2012 |
| REINSPECTION FEE | ¤40.00 | 06/27/2012 |
| REINSPECTION FEE | ¤40.00 | 03/07/2012 |
| REVISION | ¤40.00 | 03/07/2012 |
| SITE PLAN 20 | ¤20.00 | 01/13/2012 |
| SURCHARGE FS 533.721 | ¤2.00 | 01/13/2012 |
| SURCHARGE - FS 468.631 | ¤2.00 | 01/13/2012 |
| BUILDING DISCOUNT 100% | (¤198.00) | 01/13/2012 |
| PERMIT FEE | ¤260.00 | 01/13/2012 |
| PLAN CHECK FEE | ¤40.00 | 01/13/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤286.00 |