I want to search for...

Permit #2012010340

Permit Details

Status: COED

Parcel Id: 07-11-31-7006-00010-0480
CONDITIONED SPACE: 2390 sqft
GARAGE: 548 sqft
OPENED PORCH (WITH ROOF) : 470 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 3520 sqft
Block: 00010
Subdivision: 2213 - SECTION 6-FLORIDA PARK
Job Phone: (386)445-9393
Location Address: 13 FLOYD CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/17/2012
NOC: RECORDED
Applicant name: ANTONIO AMARAL JR
Owner: ANTONIO A & MARIA AMARAL

Address

13 UTILITY DRIVE

PALM COAST, FL 32137

Lot: 0480
Contracted Stated Job Value: ¤220,000.00
Job Description: NEW HOME SINGLE RESIDENCE WITH RETAINING WALL
Type: CN

Contractor

AMARAL CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32135

CBC058062 (Exp: 08/31/2020) (386)445-9393 (386)446-0403

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ET11000823 (Exp: 09/09/2016) (386) 437-0607 (386)437-1847
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
ANTONIO JR AMARAL
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2018) (386)445-9393 (386)446-0403

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 02/28/2013 APPROVED DSPENCER
BLD - BUILDING FINAL 02/26/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROW DAMAGE 02/25/2013 APPROVED RGROSS
Note: REASON FOR FAILURE : Road damage where driveway meets the road edge. CORRECTION NEEDED : Pull asphalt where driveway meets the road edge and replace. See painted lines for repair. NOTES : Contractor ordered to repair ROW damage by March 8, 2013
BLD - BUILDING FINAL 02/25/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 2/25/2013 1:30:04 PM OUTLET IN GUEST BATH LOOSE/NO POWER TO GFI OUTLET BEHIND WATER HEATER/
FINAL APRON (AFTER POUR/DRIVEWAY) 02/25/2013 APPROVED RGROSS
BLD - BUILDING FINAL 12/13/2012 CANCELLED BY APPLICANT JMONTARULI
Note: Needs early power inspection 1st
ELECTRIC - EARLY POWER 12/13/2012 APPROVED DROCKWELL
FINAL SURVEY (OFFICE USE ONLY) 08/16/2012 APPROVED JJOSEPH
PRE-APRON (PRE-POUR/DRIVEWAY) 07/12/2012 APPROVED GLALIMA
Note: READY TO POUR
STORMWATER EROSION CONTROL 06/29/2012 APPROVED DROCKWELL
Note: conplaint from 11 floyd ct about run off
INSULATION 05/04/2012 APPROVED CMINI
ALL ROUGH 05/02/2012 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 04/30/2012 APPROVED DROCKWELL
ALL ROUGH 04/30/2012 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 4/30/2012 2:56:21 PM UFER GROUND NOT WIRED/PROVIDE A/C PLANS AS REQUIRED-CHECKED EVERY PAPER IN BOX A/C PLANS NOT THERE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/20/2012 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 4/20/2012 11:56:58 AM TAP-CON 2X4 AT WEST PORCH WALL SUPPORTING ROOF SHEATHING/THREADED RODS IN PORCH BATH NOT COMPLETED
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/17/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 4/17/2012 3:42:49 PM NED TO HAVE CITY APPROVED STAMPED SET OF PLANS ON JOB FOR INSPECTION...NEED TO CLEAR SWALE FOR WATER FLOW AS PER REQUEST ON LAST INSPECTION.
TIE BEAM / LINTEL 04/05/2012 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 04/04/2012 APPROVED JHINDMAN
RETAINING WALL FOUNDATION 03/22/2012 APPROVED DROCKWELL
MONOLITHIC SLAB 03/21/2012 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 3/21/2012 12:10:06 PM TONY-YOU WILL NEED TO SHOW STEMWALL FOOTING TIE-IN TO SLAB DETAIL AT STEM WALL INSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 03/16/2012 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ELECTRIC TEMP POLE 03/16/2012 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 03/15/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 3/15/2012 3:29:21 PM NEED TO HAVE APPROVED RISER DIAGRAHM FOR PLUMING 1ST ROUGH
ELECTRIC TEMP POLE 03/14/2012 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 3/14/2012 11:54:26 AM BRACE TEMP POLE AS REQUIRED

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/16/2012 08/16/2012
Note: Released By: JJOSEPH final survey
ZON COMPLETE 08/16/2012 08/16/2012
Note: Released By: JJOSEPH final survey
SW1 COMPLETE 04/04/2012 04/04/2012
Note: Released By: JHINDMAN foundation survey
ZON COMPLETE 04/04/2012 04/04/2012
Note: Released By: JHINDMAN foundation survey
BLD COMPLETE 02/16/2012 02/16/2012
Note: Released By: JHINDMAN
ZON COMPLETE 02/15/2012 02/16/2012
BLD HOLD 02/15/2012 02/15/2012
Note: Held By: JHINDMAN provide the Florida product approval for the garage door. The plans provided are only the installation instructions.
ELEC COMPLETE 02/15/2012 02/15/2012
ELEC COMPLETE 02/06/2012 02/06/2012
BLD HOLD 02/06/2012 02/06/2012
Note: Held by Freodica 1. Provide Florida product approval for exterior door and garage door as previously requested.
ZON HOLD 01/26/2012 01/27/2012
Note: D Ramirez 1. Because this site is facing a canal foundation plantings are required, per code, on the rear of house and banding are required on rear side windows. 2. Show mechanical equipment being screened. 3. Pool will be done by separate permit and X out of the site plan, should the retaining wall be part of this permit? If retaining wall is to be reviewed with this permit depict location of the retaining wall on the site plan. 4. Quoins and banding shall wrap around the corners of the structure for a least 2 feet.
URB COMPLETE 01/26/2012 01/31/2012
PLUM COMPLETE 01/26/2012 01/26/2012
Note: Released by Freodica
ELEC HOLD 01/26/2012 01/26/2012
Note: Revise grounding electrode conductor from number 6 to number 4 as per article T 250.66
BLD HOLD 01/26/2012 01/26/2012
Note: Held by Freodica 1. Provide Florida product approval for exterior door and garage door as previously requested.
ENGIN1 COMPLETE 01/18/2012 01/19/2012
ZON HOLD 01/18/2012 01/19/2012
Note: D Ramirez 1. Site plan layout does not match the building plans. 2. Provide a landscaping plan to show the following- a. trees required (1 tree for every 2,500 sq. ft.) b. foundation plantings wrapping corner of house, side and rear. c. type of sod to be installed d. mechanical equipment screened 3. Quoins and banding shall wrap around the corners of the structure for a least 2 feet.
SW1 COMPLETE 01/18/2012 01/18/2012
Note: Released by JJoseph
URB HOLD 01/18/2012 01/23/2012
Note: Need to submit a landscape plan
MECH COMPLETE 01/18/2012 01/18/2012
Note: Released by Freodica
PLUM HOLD 01/18/2012 01/18/2012
Note: Held by Freodica 1. Provide sanitary riser diagram signed by plumbing contractor including his License Number. 2. Provide piping material specifications for sanitary and domestic water.
BLD HOLD 01/18/2012 01/19/2012
Note: Held by Freodica 1. Building plans do not match with site plan. Revise and coordinate. 2. Provide truss package. 3. Provide Florida Product Approval for exterior windows, doors and garage door including maufacturer's installation instructions. Please note the house is located in wind-borne debris region and therefore requires opening protections.
ELEC HOLD 01/18/2012 01/19/2012
Note: 1. provide carbon monoxide detectors outside of the bedrooms. 2. provide electric panel location. 3. provide GFCI protection at the outside receptacles.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/01/2013
REINSPECTION FEE ¤40.00 03/01/2013
REINSPECTION FEE ¤40.00 03/01/2013
REINSPECTION FEE (¤40.00) 12/07/2012
REINSPECTION FEE (¤40.00) 12/07/2012
REINSPECTION FEE ¤40.00 12/07/2012
REINSPECTION FEE ¤40.00 12/07/2012
REINSPECTION FEE ¤40.00 12/07/2012
REINSPECTION FEE (¤40.00) 12/07/2012
BUILDING DISCOUNT 100% (¤1,257.30) 02/17/2012
ELECTRIC FEE ¤231.00 02/17/2012
IMPACT FEE SCHOOL ¤3,600.00 02/17/2012
FIRE RESIDENTIAL IMPACT FEE ¤195.63 02/17/2012
MECHANICAL FEE ¤231.00 02/17/2012
PERMIT FEE ¤20.00 02/17/2012
PARKS IMPACT FEE ¤1,246.06 02/17/2012
PLAN CHECK FEE ¤114.00 02/17/2012
PLUMBING FEE ¤231.00 02/17/2012
NEW RESIDENTIAL INSPECTIONS ¤570.00 02/17/2012
SITE PLAN 20 ¤20.00 02/17/2012
SURCHARGE FS 533.721 ¤2.10 02/17/2012
SURCHARGE - FS 468.631 ¤2.10 02/17/2012
STORM WATER PERMIT FEES ¤80.00 02/17/2012
TRANSPORTATION IMPACT FEE ¤2,915.02 02/17/2012
Fees Total Due: ¤0.00 Total Paid: ¤8,320.61