Permit #2012030357

Permit Details

Status: FINAL

Parcel Id: 27-10-30-0000-01010-0010
Block: 01010
Subdivision: -
Job Phone: (386)547-9834
Location Address: 6595 BELLE TERRE PKWY
Type: BC - BUILDING COMMERCIAL
Issue Date: 04/19/2012
NOC: RECORDED
Applicant name: RAMON MICHAEL GIACCONE
Owner: PALM COAST UNITED METHODIST CHURCH INC

Address

5200 BELLE TERRE PKWY

PALM COAST, FL 32137

Lot: 0010
Contracted Stated Job Value: ¤100,000.00
Job Description: PICNIIC PAVILION
Type: CN

Contractor

VERITAS CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

13 SMITH TRAIL

PALM COAST, FL 32164

CBC1251714 (Exp: 08/31/2026) (386)547-9834 (386)437-2016

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 02/11/2013 APPROVED CMINI
ELECTRIC FINAL 02/11/2013 FINAL APPROVED CMINI
FIRE FINAL 09/20/2012 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
BUILDING FINAL 09/18/2012 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 9/18/2012 2:55:02 PM NEED TO CALL IN ELECTRIC FINAL AND PLUMBING FINAL
FIRE FINAL 09/18/2012 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 9/18/2012 11:27:15 AM 1. PROVIDE 10 LB ABC FIRE EXTINGUISHER PER PLANS AND NFPA10.
ELECTRIC - EARLY POWER 08/30/2012 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 8/30/2012 1:49:58 PM CALLED FPL AT 10:45 TO RELEASE POWER,SPOKE WITH SUSAN
LATH/BRICK/WATER BARRIER 07/27/2012 APPROVED CMINI
Note: Inspection Requested at 7/26/2012 9:37:54 PM LATH AND BRICK ARE N/A
FIREWALL 07/26/2012 APPROVED CMINI
Note: Inspection Requested at 7/25/2012 4:01:00 PM FIREWALL IS N/A
ELECTRIC 2ND ROUGH 07/26/2012 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 7/26/2012 2:57:17 PM NEED REVISION FOR ANY ADDED CIRCUITS TO PANEL AND PANEL SCHEDULE CHANGE TO PLAN FOR FINAL
ELECTRIC 1ST ROUGH 07/26/2012 APPROVED - AS NOTED CMINI
Note: Inspection Requested at 7/25/2012 3:57:14 PM INSPECTION FOR SITE LIGHTING PER DISCUSSION W/CHAR Inspection Resulted at 7/26/2012 2:57:16 PM SITE LIGHTING UNDERGROUND
MONOLITHIC SLAB 07/26/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION Inspection Requested at 7/25/2012 3:59:09 PM INSPECT FLOOR DRAIN FLOOR CUT PER DISCUSSION W/CHA
PLUMBING 2ND ROUGH 07/26/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION
PLUMBING 2ND ROUGH 07/25/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 7/25/2012 1:24:17 PM NEED TO HAVE TEST GUAGE FOR WATER PIPE AND NEED 5`` HEAD PRESSURE ON DWV PER FPC 312
ELECTRIC 2ND ROUGH 07/25/2012 CANCELLED BY APPLICANT CMINI
ABOVE CEILING 07/25/2012 APPROVED - AS NOTED RMARVEL
Note: Inspection Resulted at 7/25/2012 10:37:18 AM NOT APPLICABLE.
FRAMING 07/24/2012 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 7/24/2012 2:48:41 PM INSTALL TAIL ON TRUSS THAT IS MISSING
ROOF SHEATHING / BRACE / TIE DOWN 07/24/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION
FRAMING 07/20/2012 Disapproved - NO FEE CMINI
Note: Inspection Resulted at 7/20/2012 2:42:54 PM MISSING ANCHOR BOLTS AT 24" O.C. AT GABLE END SILL PLATE PER PLAN...AT VALLEY FRAMING WHEN USING 2X8 RAFTERS PLAN CALLS FOR 2X10 RIDGE..MISSING BUCKET FOR RIDGE ON FRONT SIDEL30S USED INSTEAD..MISSING COLLAR TIES PER PLAN DETAIL..MISSING TAIL ON TRUSS RO2 LEFT OF COLUMN..PLAN SHOWING X-BRACING GOING OUT TO 12``
ROOF SHEATHING / BRACE / TIE DOWN 07/20/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 7/20/2012 2:42:53 PM MISSING ANCHOR BOLTS AT 24" O.C. AT GABLE END SILL PLATE PER PLAN...AT VALLEY FRAMING WHEN USING 2X8 RAFTERS PLAN CALLS FOR 2X10 RIDGE..MISSING BUCKET FOR RIDGE ON FRONT SIDEL30S USED INSTEAD..MISSING COLLAR TIES PER PLAN DETAIL..MISSING TAIL ON TRUSS RO2 LEFT OF COLUMN..PLAN SHOWING X-BRACING GOING OUT TO 12``
LINTEL 06/19/2012 APPROVED CMINI
FOUNDATION SURVEY - OFFICE USE ONLY 06/14/2012 APPROVED JMCGOWEN
MONOLITHIC SLAB 05/25/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION
FOOTER 05/25/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION
FOOTER 05/24/2012 Disapproved - NO FEE CMINI
Note: Inspection Resulted at 5/24/2012 3:46:50 PM NEED TO HAVE COMPACTION RESULTS THAT SHOW 95%OR BETTER PER PLAN DETAILS.NEED TO HAVE TERMITE TREATMENT CERT. PER PLAN DETAIL.NEED TO CREATE AN RELIEVING ARCH IN ORDER TO MAINTAIN 3" CLEARANCE OVER OR UNDER PIPES FROM REINFORCING STEEL .PER NOTE B.5 IN GENERAL NOTES
MONOLITHIC SLAB 05/24/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 5/24/2012 3:46:49 PM NEED TO HAVE COMPACTION RESULTS THAT SHOW 95%OR BETTER PER PLAN DETAILS.NEED TO HAVE TERMITE TREATMENT CERT. PER PLAN DETAIL.NEED TO CREATE AN RELIEVING ARCH IN ORDER TO MAINTAIN 3" CLEARANCE OVER OR UNDER PIPES FROM REINFORCING STEEL .PER NOTE B.5 IN GENERAL NOTES.
PLUMBING 1ST ROUGH 05/21/2012 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 5/21/2012 1:28:43 PM CORRECTED WORK TO MATCH PLANS
PLUMBING 1ST ROUGH 05/14/2012 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 5/14/2012 3:46:53 PM PLUMBER MET ME ON SITE TO GO OVER WHAT WAS NEEDED TO APPROVE INSPECTION.REVISION SHOWING CHANGES TO THE PLAN NEEDED
PLUMBING 1ST ROUGH 05/10/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 5/10/2012 3:39:26 PM NEED TO REVISE PLAN SHOWING ACTUAL SIZES ON JOB.PLAN SHOWING 4"LINE INSTALLED IS 3". ALSO VTR THAT IS CHANGED TO 2" FROM 3" AND WATER PIPE THAT IS SHOWING 1-1/4" CHANGED TO 3/4"
ELECTRIC 1ST ROUGH 05/10/2012 APPROVED - AS NOTED CMINI
Note: requested by contractor Inspection Resulted at 5/10/2012 3:39:26 PM UNDER SLAB ONLY

Review History

Department Status Date In Date Out
ELEC COMPLETE 08/08/2012 08/08/2012
ENGIN1 COMPLETE 06/12/2012 06/13/2012
ZON COMPLETE 06/11/2012 06/11/2012
Note: Released By: JGONZALEZ foundation survey per sara lockhart review
PLUM COMPLETE 05/21/2012 05/21/2012
Note: Plumbing revision previously submitted by plumbing contractor was cancelled by same.
PLUM HOLD 05/15/2012 05/15/2012
Note: Revisions shall be signed and sealed by engineer of record who originally did the design.
PLUM COMPLETE 04/13/2012 04/16/2012
BLD COMPLETE 04/13/2012 04/16/2012
ELEC COMPLETE 04/13/2012 04/16/2012
BLD HOLD 03/13/2012 03/13/2012
Note: 1. Provide engineered wood trusses as per plan. 2. Provide Florida Product Approval for fiberglass roofing material.
ELEC HOLD 03/13/2012 03/13/2012
Note: electric plan is a copyrighted material and shall be signed by the engineer or a licensed electric contractor can sign the plan and his license number is indicated on it provided all information on plan title block is removed. Provide electric load calculation
ENGIN1 COMPLETE 03/13/2012 03/14/2012
Note: No review required
FI1 COMPLETE 03/13/2012 03/15/2012
PLUM HOLD 03/13/2012 03/13/2012
Note: Plumbing plan is a copyrighted material and shall be signed by the engineer or a licensed plumbing contractor can sign the plan and his license number is indicated on it provided all information on plan title block is removed.
UD1 COMPLETE 03/13/2012 03/14/2012
ZON COMPLETE 03/13/2012 03/15/2012

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/23/2012
REINSPECTION FEE ¤40.00 09/23/2012
REVISION ¤40.00 09/23/2012
REINSPECTION FEE ¤40.00 08/07/2012
REINSPECTION FEE ¤40.00 08/07/2012
REINSPECTION FEE ¤40.00 08/07/2012
REINSPECTION FEE ¤40.00 08/07/2012
SITE PLAN 20 ¤20.00 04/19/2012
SURCHARGE FS 533.721 ¤2.00 04/19/2012
SURCHARGE - FS 468.631 ¤2.00 04/19/2012
ADMIN COMMERCIAL ¤60.00 04/19/2012
BUILDING DISCOUNT 100% (¤868.50) 04/19/2012
ELECTRIC FEE ¤120.00 04/19/2012
IMPACT FEE FIRE NONRESIDENTIAL ¤448.59 04/19/2012
FIRE PLANS REVIEW ¤25.00 04/19/2012
IMPACT FEE TRANSPORTATION ¤4,091.08 04/19/2012
PERMIT FEE ¤550.00 04/19/2012
PLAN CHECK FEE ¤115.00 04/19/2012
PLUMBING FEE ¤120.00 04/19/2012
Fees Total Due: ¤0.00 Total Paid: ¤4,965.17