Permit #2012030838
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00270-0020 |
| CONDITIONED SPACE: 1966 sqft |
| GARAGE: 464 sqft |
| PATIO/DECK (NO ROOF) : 149 sqft |
| OPENED PORCH (WITH ROOF) : 61 sqft |
| Total Square Footage: 2640 sqft |
| Block: 00270 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 386-672-6101 |
| Location Address: 10 WHITE STAR DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/01/2012 |
| NOC: RECORDED |
| Applicant name: JOHN DAVID MINABERRY |
| Owner: RODRIGUEZ, MIRNA DE LA C |
|
Address 10 WHITE STAR PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KEYSTONE HOMES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1339 W GRANADA BLVD ORMOND, FL 32174 |
CRC1329222 (Exp: 08/31/2026) | 386-672-6101 | 386-672-6102 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone |
| CANCEL |
17 UNIMAY CT BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2022) | 386-931-2568 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
WAYNE A PHILLIPS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
357 ANDREWS ST ORMOND BEACH, FL 32174 |
CVC56698 (Exp: 08/31/2026) | (386)673-9720 | (386)673-9840 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/16/2012 | FINAL APPROVED | RMARVEL |
| Note: Inspection Resulted at 11/16/2012 3:02:34 PM OUTSTANDING INSPECTION. UNABLE TO 99 | |||
| ROW DAMAGE | 11/16/2012 | APPROVED - AS NOTED | RGROSS |
| Note: 11/16/12 - SWALE DOES NEED TO BE SODDED. PER GARY. THERE WAS AN APPARENT MISCOMMUNICATION AS WHETHER IT NEEDED TO BE SODDED. ANY QUESTIONS CALL GARY. 11/16/12 - PER GARY CONTRACTOR CONTACTED LATER WORKING ON SOD IN SWALE . WILL DO RIDE BY TO VERIFY MON. MORNING.11/19/12. | |||
| U -UTILITY RESIDENTIAL FINAL | 11/16/2012 | APPROVED | DSPENCER |
| FINAL SURVEY (OFFICE USE ONLY) | 11/15/2012 | APPROVED | JMCGOWEN |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/13/2012 | APPROVED | RGROSS |
| Note: 11/13/12 Explained to contractor that sod had to be even or below the road. He said they would make sure of that. | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 11/05/2012 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION 11/5/12 FLAG LOT. READY TO POUR | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 10/25/2012 | PARTIALLY APPROVED | GLALIMA |
| Note: ON SITE WITH BUILDER. TOLD HIM TO REKE OFF ALL " ROOTS AND OTHER 'THEN POUR THE DRIVEWAY FROM GARAGE BACK TO TOP OF BANK AT STREET TO RIGHT OF WAY. AFTER THAT HE WILL FORM DRIVEWAY AT STREET AND SET CULVERT PIPE AND CALL FOR PART 2 OF DRIVEWAY INSPECTION . | |||
| ELECTRIC - EARLY POWER | 10/24/2012 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 10/24/2012 3:45:05 PM CALLED SUSAN FROM FPL TO RELEASE POWER.3:00 | |||
| U - SEWER TIE IN | 10/22/2012 | APPROVED | KKING |
| INSULATION | 08/08/2012 | APPROVED | RMARVEL |
| LATH/BRICK/ WATER BARRIER | 08/07/2012 | APPROVED | CMINI |
| ALL ROUGH | 08/06/2012 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 08/02/2012 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 8/2/2012 1:27:06 PM OFF-RIDGE VENTING NOT TO PLAN/TIGHTEN THREADED ROD IN FRAMING AT WATER HEATER/FILL TUB BOX WITH APPROPRIATE MATERIAL PER FBC 101.6.1.2/NO WATER TEST ON SANITARY PER FBC P2503.5.1/ UFER GROUND NOT CONNECTED TO FOOTING STEEL PER NEC 250.8 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/23/2012 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/20/2012 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 7/20/2012 2:58:24 PM MISSING ENGINEERING ON TRUSS 03. TIGHTEN NUT ON ANCHOR AT BEARING WALL TO CMU ATTACHMENT. REMOVE SHINERS AT SHEATHING TO TRUSS NAILING. | |||
| TIE BEAM / LINTEL | 06/06/2012 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 05/31/2012 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 05/18/2012 | APPROVED - AS NOTED | CMINI |
| Note: Trisha called to schedule this inspection Inspection Resulted at 5/18/2012 3:50:01 PM APPROVED | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/16/2012 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/15/2012 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 5/15/2012 2:08:12 PM PROVIDE REQUIRED PLUMBING RISER DIAGHRAM AT THIS INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 11/15/2012 | 11/15/2012 |
| ZON | COMPLETE | 11/15/2012 | 11/15/2012 |
| Note: Released By: JMCGOWEN foundation survey | |||
| SW1 | COMPLETE | 11/13/2012 | 11/15/2012 |
| Note: Released By: JMCGOWEN foundation survey | |||
| ZON | COMPLETE | 05/31/2012 | 05/31/2012 |
| Note: Released By: FREODICA FOUNDATION SURVEY | |||
| SW1 | COMPLETE | 05/31/2012 | 05/31/2012 |
| Note: Released By: FREODICA FOUNDTATION SURVEY | |||
| ELEC | COMPLETE | 04/20/2012 | 04/20/2012 |
| BLD | COMPLETE | 04/20/2012 | 04/20/2012 |
| ENGIN1 | COMPLETE | 04/20/2012 | 04/23/2012 |
| ZON | COMPLETE | 04/20/2012 | 04/25/2012 |
| SW1 | COMPLETE | 04/20/2012 | 04/20/2012 |
| BLD | HOLD | 03/30/2012 | 04/02/2012 |
| Note: Provide Florida product approvals for roofing material, exteror garage door and exteror windows. | |||
| ELEC | HOLD | 03/30/2012 | 04/02/2012 |
| Note: Provide pep tank disconnect location, revise outlet location to meet 210.50 of the 2008 NEC, include pep tank circuit on electric calculation, electric calculation will need electrician’s license number and his signature, provide carbon monoxide detector locations, provide electric location, provide accessary ground terminal detail and location, provide electric riser detail to include size of service and conductor sizes | |||
| ENGIN1 | HOLD | 03/30/2012 | 04/03/2012 |
| Note: Road name on site plan incorrect. | |||
| MECH | COMPLETE | 03/30/2012 | 04/02/2012 |
| PLUM | COMPLETE | 03/30/2012 | 04/02/2012 |
| SW1 | COMPLETE | 03/30/2012 | 03/30/2012 |
| Note: Released by JJoseph | |||
| URB | COMPLETE | 03/30/2012 | 03/30/2012 |
| ZON | HOLD | 03/30/2012 | 04/04/2012 |
| Note: 1. As per chapter 5 subsection 5.04.02c5f of the Land Development Code driveways must meet the the minimum of 16ft wide at the edge of road. Revise the site plan to show the driveway at the minimum. 2. Acceptable earth tone shades shall have a Munsell lightness value (LRV) of thirty or greater. Revise the color and material sheet to increase the LRV of the wall and trim of the home. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 11/16/2012 |
| REINSPECTION FEE | ¤40.00 | 11/16/2012 |
| REINSPECTION FEE | ¤40.00 | 11/16/2012 |
| REVISION | ¤40.00 | 11/16/2012 |
| SITE PLAN 20 | ¤20.00 | 05/01/2012 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/01/2012 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/01/2012 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/01/2012 |
| TRANSPORTATION IMPACT FEE | ¤2,827.56 | 05/01/2012 |
| NEW RESIDENTIAL INSPECTIONS | ¤458.00 | 05/01/2012 |
| BUILDING DISCOUNT 100% | (¤1,045.62) | 05/01/2012 |
| ELECTRIC FEE | ¤197.40 | 05/01/2012 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/01/2012 |
| FIRE RESIDENTIAL IMPACT FEE | ¤189.75 | 05/01/2012 |
| MECHANICAL FEE | ¤197.40 | 05/01/2012 |
| PERMIT FEE | ¤20.00 | 05/01/2012 |
| PARKS IMPACT FEE | ¤1,208.67 | 05/01/2012 |
| PLAN CHECK FEE | ¤91.60 | 05/01/2012 |
| PLUMBING FEE | ¤197.40 | 05/01/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤8,206.16 |