Permit #2012050650

Permit Details

Status: COED

Parcel Id: 07-11-31-7001-000B0-0050
Block: 000B0
Subdivision: 1238 - PALM HARBOR CENTER REPLAT
Job Phone: (386)931-1917
Location Address: 9 PALM HARBOR VILLAGE WAY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 06/12/2012
NOC: RECORDED
Applicant name: BRAD MICHAEL THOMAS
Owner: BARBOSA PLAZA II INC

Address

65 BOSTON LANE

PALM COAST, FL 32137

Lot: 0050
Contracted Stated Job Value: ¤5,000.00
Job Description: SUITE 9 A - SMILES NIGHT CLUB INC - INTERIOR ALTERATION
Type: CN

Contractor

AUBURN HOMES INC.
Status Location Address State License Number Phone
HOLD

1 HARGROVE GRADE STE 1E

PALM COAST, FL 32137

CGC1506292 (Exp: 08/31/2020) (386)931-1917

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address State License Number Phone Fax
CANCEL

55 BARRISTER LN

PALM COAST, FL 32137

ER13013466 (Exp: 08/31/2014) 386-586-9144 (386)246-6305
TERRY M MCNITT
Status Location Address State License Number Phone
ACTIVE

909 MAGNOLIA TERRACE

FLAGLER BEACH, FL 32136

CFC1426001 (Exp: 08/31/2026) 386-439-3191

Inspection History

Type Request Date Result Inspector
FIRE FINAL 07/05/2012 FINAL APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
FIRE FINAL 06/25/2012 Disapproved -FEE REQUIRED JHINDMAN
Note: 1. replace the batteries in the existing exit signs. 2.Provide panic hardware on the doors per the plan.
ABOVE CEILING 06/25/2012 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 6/25/2012 3:11:02 PM ALREADY APPROVED BY R.MARVEL
BUILDING FINAL 06/25/2012 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 6/25/2012 3:14:33 PM EMERGENCY LIGHTS NOT WORKING AND PANIC HARDWARE ON DOORS NEEDED,CHECK ON FIRE FINAL
PLUMBING FINAL 06/25/2012 APPROVED CMINI
ELECTRIC FINAL 06/25/2012 APPROVED CMINI
U - UTILITY COMMERCIAL FINAL 06/25/2012 APPROVED KKING
ELECTRIC FINAL 06/22/2012 CANCELLED BY APPLICANT AIRS WEB
PLUMBING FINAL 06/22/2012 CANCELLED BY APPLICANT AIRS WEB
FIRE FINAL 06/22/2012 CANCELLED BY APPLICANT AIRS WEB
BUILDING FINAL 06/22/2012 CANCELLED BY APPLICANT AIRS WEB
ABOVE CEILING 06/22/2012 CANCELLED BY APPLICANT AIRS WEB
U - UTILITY COMMERCIAL FINAL 06/22/2012 CANCELLED BY APPLICANT AIRS WEB
ELECTRIC 2ND ROUGH 06/19/2012 APPROVED CMINI
Note: THIS IS A REINSPECTION
FRAMING 06/13/2012 APPROVED CMINI
ABOVE CEILING 06/13/2012 APPROVED RMARVEL
PLUMBING 2ND ROUGH 06/13/2012 APPROVED CMINI
ELECTRIC 2ND ROUGH 06/13/2012 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/13/2012 1:27:38 PM NEED TO OPEN BOXES TO VERIFY THEY ARE GROUNDED..QUADS THAT ARE PUT TOGETHER NEED BOND JUMPER PER 250.8(A) NEC....NEED TO REVISE PLAN SHOWING ALL NEW AND EXISTING ON FLOOR PLAN TO MATCH

Review History

Department Status Date In Date Out
ELEC COMPLETE 06/15/2012 06/15/2012
MECH COMPLETE 06/08/2012 06/11/2012
PLUM COMPLETE 06/08/2012 06/11/2012
BLD COMPLETE 06/08/2012 06/08/2012
ELEC COMPLETE 06/08/2012 06/08/2012
FI1 COMPLETE 06/08/2012 06/08/2012
MECH HOLD 05/30/2012 05/30/2012
Note: 1. Provide energy calculation due to change of occupancy use of space from business to assembly to comply with FBC 2010 Existing Building Section 909. 2. Provide occupant load. 3. Provide existing duct system layout including hvac unit capacity and proposed changes. 4. Provide outdoor air ventilation requirements per FBC 2010 Mechanical Section 403.2. 5. Provide mechanical contractor if there would be mechanical work required due to above changes.
BLD HOLD 05/30/2012 05/30/2012
Note: 1 provide detail for the existing demising wall. An A-2 occupancy next to a B or M occupancy requires a 2 hour rated wall in a nonsprinklered building.
ELEC HOLD 05/30/2012 05/30/2012
Note: Provide load calculations and panel schedule
FI1 HOLD 05/30/2012 05/30/2012
Note: the office door cannot swing in front of the exit door.
PLUM HOLD 05/30/2012 05/30/2012
Note: 1. Provide domestic water riser diagram and material specification. 2. Provide sanitary layout to coordinate with riser diagram. 3. Provide vent for 3-compartment sink and hand sink. 4. Provide DWV material specification. 5. Coordinate item numbers 5 and 6 on Equipment Schedule with Floor Plan as their description do not match.
SW1 COMPLETE 05/30/2012 05/30/2012
Note: no stormwater review nedeed(interior aleration)
UD1 COMPLETE 05/30/2012 06/04/2012
ZON COMPLETE 05/30/2012 06/04/2012

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/05/2012
REVISION ¤40.00 06/15/2012
REINSPECTION FEE ¤40.00 06/15/2012
SITE PLAN 20 ¤20.00 06/12/2012
SURCHARGE FS 533.721 ¤6.37 06/12/2012
SURCHARGE - FS 468.631 ¤6.37 06/12/2012
WORK WITHOUT PERMIT ¤386.00 06/12/2012
ADMIN COMMERCIAL ¤60.00 06/12/2012
BUILDING DISCOUNT 100% (¤347.40) 06/12/2012
ELECTRIC FEE ¤63.00 06/12/2012
FIRE PLANS REVIEW ¤25.00 06/12/2012
PERMIT FEE ¤100.00 06/12/2012
PLAN CHECK FEE ¤100.00 06/12/2012
PLUMBING FEE ¤63.00 06/12/2012
Fees Total Due: ¤0.00 Total Paid: ¤602.34