I want to search for...
Permit #2012050650
Permit Details
Status: COED
| Parcel Id: 07-11-31-7001-000B0-0050 |
| Block: 000B0 |
| Subdivision: 1238 - PALM HARBOR CENTER REPLAT |
| Job Phone: (386)931-1917 |
| Location Address: 9 PALM HARBOR VILLAGE WAY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 06/12/2012 |
| NOC: RECORDED |
| Applicant name: BRAD MICHAEL THOMAS |
| Owner: BARBOSA PLAZA II INC |
|
Address 65 BOSTON LANE PALM COAST, FL 32137 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤5,000.00 |
| Job Description: SUITE 9 A - SMILES NIGHT CLUB INC - INTERIOR ALTERATION |
| Type: CN |
Contractor
AUBURN HOMES INC.
| Status | Location Address | State License Number | Phone |
| HOLD |
1 HARGROVE GRADE STE 1E PALM COAST, FL 32137 |
CGC1506292 (Exp: 08/31/2020) | (386)931-1917 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
55 BARRISTER LN PALM COAST, FL 32137 |
ER13013466 (Exp: 08/31/2014) | 386-586-9144 | (386)246-6305 |
TERRY M MCNITT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
909 MAGNOLIA TERRACE FLAGLER BEACH, FL 32136 |
CFC1426001 (Exp: 08/31/2026) | 386-439-3191 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE FINAL | 07/05/2012 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 06/25/2012 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 1. replace the batteries in the existing exit signs. 2.Provide panic hardware on the doors per the plan. | |||
| ABOVE CEILING | 06/25/2012 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/25/2012 3:11:02 PM ALREADY APPROVED BY R.MARVEL | |||
| BUILDING FINAL | 06/25/2012 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/25/2012 3:14:33 PM EMERGENCY LIGHTS NOT WORKING AND PANIC HARDWARE ON DOORS NEEDED,CHECK ON FIRE FINAL | |||
| PLUMBING FINAL | 06/25/2012 | APPROVED | CMINI |
| ELECTRIC FINAL | 06/25/2012 | APPROVED | CMINI |
| U - UTILITY COMMERCIAL FINAL | 06/25/2012 | APPROVED | KKING |
| ELECTRIC FINAL | 06/22/2012 | CANCELLED BY APPLICANT | AIRS WEB |
| PLUMBING FINAL | 06/22/2012 | CANCELLED BY APPLICANT | AIRS WEB |
| FIRE FINAL | 06/22/2012 | CANCELLED BY APPLICANT | AIRS WEB |
| BUILDING FINAL | 06/22/2012 | CANCELLED BY APPLICANT | AIRS WEB |
| ABOVE CEILING | 06/22/2012 | CANCELLED BY APPLICANT | AIRS WEB |
| U - UTILITY COMMERCIAL FINAL | 06/22/2012 | CANCELLED BY APPLICANT | AIRS WEB |
| ELECTRIC 2ND ROUGH | 06/19/2012 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FRAMING | 06/13/2012 | APPROVED | CMINI |
| ABOVE CEILING | 06/13/2012 | APPROVED | RMARVEL |
| PLUMBING 2ND ROUGH | 06/13/2012 | APPROVED | CMINI |
| ELECTRIC 2ND ROUGH | 06/13/2012 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 6/13/2012 1:27:38 PM NEED TO OPEN BOXES TO VERIFY THEY ARE GROUNDED..QUADS THAT ARE PUT TOGETHER NEED BOND JUMPER PER 250.8(A) NEC....NEED TO REVISE PLAN SHOWING ALL NEW AND EXISTING ON FLOOR PLAN TO MATCH |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/15/2012 | 06/15/2012 |
| MECH | COMPLETE | 06/08/2012 | 06/11/2012 |
| PLUM | COMPLETE | 06/08/2012 | 06/11/2012 |
| BLD | COMPLETE | 06/08/2012 | 06/08/2012 |
| ELEC | COMPLETE | 06/08/2012 | 06/08/2012 |
| FI1 | COMPLETE | 06/08/2012 | 06/08/2012 |
| MECH | HOLD | 05/30/2012 | 05/30/2012 |
| Note: 1. Provide energy calculation due to change of occupancy use of space from business to assembly to comply with FBC 2010 Existing Building Section 909. 2. Provide occupant load. 3. Provide existing duct system layout including hvac unit capacity and proposed changes. 4. Provide outdoor air ventilation requirements per FBC 2010 Mechanical Section 403.2. 5. Provide mechanical contractor if there would be mechanical work required due to above changes. | |||
| BLD | HOLD | 05/30/2012 | 05/30/2012 |
| Note: 1 provide detail for the existing demising wall. An A-2 occupancy next to a B or M occupancy requires a 2 hour rated wall in a nonsprinklered building. | |||
| ELEC | HOLD | 05/30/2012 | 05/30/2012 |
| Note: Provide load calculations and panel schedule | |||
| FI1 | HOLD | 05/30/2012 | 05/30/2012 |
| Note: the office door cannot swing in front of the exit door. | |||
| PLUM | HOLD | 05/30/2012 | 05/30/2012 |
| Note: 1. Provide domestic water riser diagram and material specification. 2. Provide sanitary layout to coordinate with riser diagram. 3. Provide vent for 3-compartment sink and hand sink. 4. Provide DWV material specification. 5. Coordinate item numbers 5 and 6 on Equipment Schedule with Floor Plan as their description do not match. | |||
| SW1 | COMPLETE | 05/30/2012 | 05/30/2012 |
| Note: no stormwater review nedeed(interior aleration) | |||
| UD1 | COMPLETE | 05/30/2012 | 06/04/2012 |
| ZON | COMPLETE | 05/30/2012 | 06/04/2012 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/05/2012 |
| REVISION | ¤40.00 | 06/15/2012 |
| REINSPECTION FEE | ¤40.00 | 06/15/2012 |
| SITE PLAN 20 | ¤20.00 | 06/12/2012 |
| SURCHARGE FS 533.721 | ¤6.37 | 06/12/2012 |
| SURCHARGE - FS 468.631 | ¤6.37 | 06/12/2012 |
| WORK WITHOUT PERMIT | ¤386.00 | 06/12/2012 |
| ADMIN COMMERCIAL | ¤60.00 | 06/12/2012 |
| BUILDING DISCOUNT 100% | (¤347.40) | 06/12/2012 |
| ELECTRIC FEE | ¤63.00 | 06/12/2012 |
| FIRE PLANS REVIEW | ¤25.00 | 06/12/2012 |
| PERMIT FEE | ¤100.00 | 06/12/2012 |
| PLAN CHECK FEE | ¤100.00 | 06/12/2012 |
| PLUMBING FEE | ¤63.00 | 06/12/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤602.34 |