I want to search for...
Permit #2012060260
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7019-00200-0080 |
| Block: 00200 |
| Subdivision: 2214 - SECTION 19-WYNNFIELD |
| Job Phone: 321-377-8489 |
| Location Address: 74 WATERS DR |
| Type: ME - MECHANICAL |
| Issue Date: 06/29/2012 |
| NOC: Unknown |
| Applicant name: ALFRED W NYMAN JR |
| Owner: WALLACE KENNETH & DONNA SIMPSON WALLACE H&W |
|
Address 74 WATERS DR PALM COAST, FL 32164 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤7,485.00 |
| Job Description: AC UNIT CHANGE OUT 4.0 TON 13 SEERS |
| Type: CN |
Contractor
SEARS HOME IMPROVEMENT PRODUCTS INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1024 FLORIDA CENTRAL PKWY LONGWOOD, FL 32750 |
CMC1249510 (Exp: 08/31/2020) | 321-377-8489 | 407-830-0072 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 07/17/2012 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 7/17/2012 2:34:09 PM LOCKING CAPS ON REFRIGERATION PORTS LOCATED OUTDOORS. M1411.6. DUCT SEALING LETTER OF CERTIFICATION IS REQUIRED ON REPLACEMENT HVAC. ENERGY CODE 101.4.7.1.1 | |||
| HVAC FINAL | |||
| Note: THIS IS A REINSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/19/2012 | 06/19/2012 |
| Note: Released By: FREODICA submitted corrections | |||
| BLD | HOLD | 06/15/2012 | 06/15/2012 |
| Note: Held By: FREODICA answering hold comment 1. Provide the sensible and latent load capacity of the unit as previously requested. | |||
| BLD | HOLD | 06/13/2012 | 06/13/2012 |
| Note: Held By: FREODICA revised 1. The submitted information on the hvac unit equipment total cooling load capacity is smaller than the required capacity based on the heating/cooling load calculations. Provide also the sensible and latent load capacity of the unit. | |||
| BLD | HOLD | 06/12/2012 | 06/12/2012 |
| Note: Held By: FREODICA 1. Provide the manufacturer, model number, efficiiency, and sensible/latent load capacity of the units to be installed. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/25/2013 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/29/2012 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/29/2012 |
| BUILDING DISCOUNT 100% | (¤76.04) | 06/29/2012 |
| MECHANICAL FEE | ¤64.49 | 06/29/2012 |
| PERMIT FEE | ¤20.00 | 06/29/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤52.45 |