I want to search for...
Permit #2012090517
Permit Details
Status: COED
| Parcel Id: 07-11-31-7016-00030-0080 |
| CONDITIONED SPACE: 1745 sqft |
| GARAGE: 473 sqft |
| OPENED PORCH (WITH ROOF) : 45 sqft |
| PATIO/DECK (NO ROOF) : 27 sqft |
| Total Square Footage: 2290 sqft |
| Block: 00030 |
| Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE |
| Job Phone: 386-672-6101 |
| Location Address: 4 COLLEEN CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/30/2012 |
| NOC: RECORDED |
| Applicant name: JOHN DAVID MINABERRY |
| Owner: WEBER, LISA A |
|
Address 4 COLLEN CT PALM COAST, FL 32137 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤174,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KEYSTONE HOMES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1339 W GRANADA BLVD ORMOND, FL 32174 |
CRC1329222 (Exp: 08/31/2026) | 386-672-6101 | 386-672-6102 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone |
| CANCEL |
17 UNIMAY CT BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2022) | 386-931-2568 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 05/16/2013 | APPROVED | GLALIMA |
| U -UTILITY RESIDENTIAL FINAL | 05/16/2013 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 05/15/2013 | APPROVED | DROCKWELL |
| PROJECT STATUS (OFFICE USE) | 04/22/2013 | APPROVED - AS NOTED | JMCGOWEN |
| Note: Jerry H and I went to investigate a storm water complaint, after inspecting we got with the contractor and he agreed to regrade the area in question | |||
| FINAL SURVEY (OFFICE USE ONLY) | 04/09/2013 | APPROVED | JHINDMAN |
| GRAVITY SEWER TEST | 03/28/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 03/27/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 3/27/2013 2:53:24 PM NO WATER IN COVERED UP PIPE.EXPOSE PIPE AND FILL FLUSH | |||
| U - SEWER TIE IN | 03/27/2013 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 03/25/2013 | Disapproved -FEE REQUIRED | KKING |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/25/2013 8:28:47 AM CONNECTION COVERED UP. CLEAN-OUT IN WRONG PLACE | |||
| U - SEWER TIE IN | 03/22/2013 | Disapproved - NO FEE | DSPENCER |
| Note: Inspection Resulted at 3/22/2013 1:35:59 PM CONNECTION DOES NOT MEET THE CITY UTILITY STANDARDS. SEE THE SEWER TIE IN DETAILS ON THE CITY WEB SITE. WE DO NOT ALLOW A WYE AS A BEND AND CLEANOUT STACK PIPE INSTEAD USE A 45 TO LEVEL OFF AND A WYE WITH A 45 FOR THE STACK WITHEN 3`` . ALSO THE PLUMBER IS REQUESTED TO CALL THE DAY WORK IS PLANNED TO COORDINATE AN EXPECTED TIME OF COMPLETION TO ARRANGE FOR THE INSPECTOR TO PERFORM THE INSPECTION SO THE HOLE CAN BE FILLED UP TO THE CLEANOUT AT THAT TIME. THIS WILL REDUCE THE LIABILIY FOR THE BUILDER AND REDUCE FAILED INSPECTIONS FOR THE PLUMBER IT REDUCES CALL BACKS FROM WATER FILLING THE HOLE AND CAVEIN CAUSING CALL BACKS HAVING TO UNCOVER FOR THE INSPECTION. | |||
| ELECTRIC - EARLY POWER | 03/21/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 03/08/2013 | APPROVED | RGROSS |
| INSULATION | 01/25/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 1/25/2013 2:43:07 PM LEFT NOTE AT LAST INSPECTION (ALL ROUGH) LOW-VOLT WIRING NEEDED TO BE PROTECTED WITH NAIL PLATES THRU-OUT HOUSE AND WOULD CHECK AT INSULATION INSPECTION-PLATES NOT INSTALLED. | |||
| INSULATION | 01/25/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 01/24/2013 | APPROVED | DROCKWELL |
| ELECTRIC - EARLY POWER | 01/24/2013 | CANCELLED BY APPLICANT | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/22/2013 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 1/22/2013 2:45:31 PM LOW VOLT WIRING NEEDS NAIL PLATES MANY AREA``S FOR PROTECTION-WILL CHECK AT INSULATION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/16/2013 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/16/2013 12:35:02 PM ROOF METALS CHECK | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/14/2013 | CANCELLED BY APPLICANT | DROCKWELL |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/08/2013 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/8/2013 11:42:40 AM AS MENTIONED LAST INSPECTION-NEED ROOF METALS INSTALLED BY THIS INSPECTION.CALL FOR ANOTHER INSPECTION AND NOTE ROOF METALS ONLY-BEFORE SHINGLES. | |||
| ELECTRIC - EARLY POWER | 12/27/2012 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 12/27/2012 3:38:38 PM NOT READY FOR POWER INSPECTION..NO TEMP POLE INSTALLED AT THIS TIME.. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/07/2012 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 12/7/2012 3:05:23 PM NEED TRUSS REPAIR LETTER FROM ENGINEER FOR 06 AND 07/ROOF METALS ON AT THIS INSPECTION/COMPLETE GABLE BRACING/MISSING 2X AT GABLE END WALLS/COMPLETE STRAPPING/NOT READY FOR INSPECTION-INCOMPLETE INSPECTION. | |||
| TIE BEAM / LINTEL | 12/04/2012 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION requested by contractor | |||
| TIE BEAM / LINTEL | 12/03/2012 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 12/3/2012 12:05:41 PM SEE DETAIL ON MASONRY WALL BOND BEAM HEIGHT CHANGE 24 IN OR GREATER ADD STEEL PER DETAIL-CLEAN OUT EXCCESS MORTAR IN CELL WHERE MARKED W/PAINT | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/30/2012 | APPROVED | FREODICA |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/19/2012 | CANCELLED BY INSPECTOR | DROCKWELL |
| Note: Inspection Resulted at 11/19/2012 3:00:07 PM DUPLICATE-ALREADY INSPECTED | |||
| MONOLITHIC SLAB | 11/19/2012 | APPROVED | DROCKWELL |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/15/2012 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 04/09/2013 | 04/09/2013 |
| Note: Released By: JHINDMAN Marked Must Apply By: JHINDMAN final survey | |||
| SW1 | COMPLETE | 04/08/2013 | 04/09/2013 |
| Note: Released By: JHINDMAN final survey | |||
| BLD | COMPLETE | 12/19/2012 | 12/20/2012 |
| ZON | COMPLETE | 11/30/2012 | 11/30/2012 |
| Note: Released By: FREODICA foundation survey | |||
| SW1 | COMPLETE | 11/30/2012 | 11/30/2012 |
| Note: Released By: FREODICA foundation survey | |||
| MECH | COMPLETE | 10/17/2012 | 10/17/2012 |
| SW1 | COMPLETE | 10/08/2012 | 10/09/2012 |
| MECH | HOLD | 10/08/2012 | 10/09/2012 |
| Note: 1. The HVAC Plan shall have the signature and license number of the HVAC contractor per 2010 FBC 107.3.4.3. | |||
| BLD | COMPLETE | 10/08/2012 | 10/09/2012 |
| ELEC | COMPLETE | 10/08/2012 | 10/09/2012 |
| PLUM | COMPLETE | 10/08/2012 | 10/09/2012 |
| ZON | COMPLETE | 10/08/2012 | 10/09/2012 |
| BLD | HOLD | 09/24/2012 | 09/25/2012 |
| Note: 1. Provide correct exposure design the city of Palm Coast does not have any exposure D areas. 2010FBC R301.2.1.4.3. 2. Provide Florida Product Approval for the garage door and the roofing. 2010 FBC 107.2.1. 3. Provide a non bearing wall detail per 2010 FBC R602.1.3.1. 4. The coquina rock seawall wall requires a seperate permit.per AHJ. | |||
| ELEC | HOLD | 09/24/2012 | 09/25/2012 |
| Note: 1. provide GFCI receptacles in bathroom 2. 2008NEC 210.8. 2. Provide panel load calculation that include the 50 Amp subpanel. Remove the pep tank load from the calculations as this house is not in a pep area.2008 NEC220. 3. Provide the service entrence amperage 2008NEC 230. 4. Provide conductor sizes for the service enterance, grounding, and subpanel feeders. 2008 NEC 230.23, 230 part IV. | |||
| ENGIN1 | COMPLETE | 09/24/2012 | 09/28/2012 |
| MECH | HOLD | 09/24/2012 | 09/25/2012 |
| Note: Hvac plan shall have signature and license number of hvac contractor per 2010 FBC Section 107.3.4.3. | |||
| PLUM | COMPLETE | 09/24/2012 | 09/25/2012 |
| SW1 | HOLD | 09/24/2012 | 09/24/2012 |
| Note: Held by JJoseph 1.Provide elevations an all adjacent properties lines at a minimum 20 foot intervals on a 10 foot offset outside the property lines. 2.Flooding or draining onto adjeacent properties will not be allowed. 3. Provide benchmark location abd elevation using NAVD 1988. | |||
| UD1 | COMPLETE | 09/24/2012 | 09/25/2012 |
| URB | COMPLETE | 09/24/2012 | 09/24/2012 |
| ZON | COMPLETE | 09/24/2012 | 09/29/2012 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/21/2013 |
| REINSPECTION FEE | ¤40.00 | 05/21/2013 |
| REINSPECTION FEE | ¤40.00 | 05/21/2013 |
| REINSPECTION FEE | ¤40.00 | 05/21/2013 |
| REINSPECTION FEE | ¤40.00 | 05/21/2013 |
| REINSPECTION FEE | ¤40.00 | 05/21/2013 |
| REVISION | ¤40.00 | 05/21/2013 |
| SITE PLAN 20 | ¤20.00 | 10/30/2012 |
| SURCHARGE FS 533.721 | ¤2.00 | 10/30/2012 |
| SURCHARGE - FS 468.631 | ¤2.00 | 10/30/2012 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/30/2012 |
| TRANSPORTATION IMPACT FEE | ¤2,827.56 | 10/30/2012 |
| NEW RESIDENTIAL INSPECTIONS | ¤402.00 | 10/30/2012 |
| BUILDING DISCOUNT 100% | (¤939.78) | 10/30/2012 |
| ELECTRIC FEE | ¤180.60 | 10/30/2012 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/30/2012 |
| FIRE RESIDENTIAL IMPACT FEE | ¤198.38 | 10/30/2012 |
| MECHANICAL FEE | ¤180.60 | 10/30/2012 |
| PERMIT FEE | ¤20.00 | 10/30/2012 |
| PARKS IMPACT FEE | ¤1,281.86 | 10/30/2012 |
| PLAN CHECK FEE | ¤80.40 | 10/30/2012 |
| PLUMBING FEE | ¤180.60 | 10/30/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤8,396.22 |