I want to search for...
Permit #2012090641
Permit Details
Status: COED
| Parcel Id: 48-11-31-1710-00000-0650 |
| CONDITIONED SPACE: 2765 sqft |
| GARAGE: 825 sqft |
| PATIO/DECK (NO ROOF) : 102 sqft |
| OPENED PORCH (WITH ROOF) : 621 sqft |
| Total Square Footage: 4313 sqft |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: 386-947-4481 |
| Location Address: 35 SCARLET OAK CIR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/18/2012 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: PANICO ROBERT A & ANDREA D H&W |
|
Address 92 FRONT STREET PALM COAST, FL 32137 |
| Lot: 0650 |
| Contracted Stated Job Value: ¤275,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BENJAMIN EDWARD SMITH
| Status | Location Address | State License Number | Phone |
| CANCEL |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13004288 (Exp: 08/31/2016) | 386-265-2687 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 06/11/2013 | FINAL APPROVED | DSPENCER |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 06/10/2013 | APPROVED | RGROSS |
| BLD - BUILDING FINAL | 06/07/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: approved by Dave Eversole Inspection Resulted at 6/7/2013 2:46:26 PM INTERSYSTEM BONDING TERMINATION NEEDED 250.94 ..FINAL SURVEY NOT ON SITE | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/06/2013 | APPROVED | JMCGOWEN |
| ELECTRIC - EARLY POWER | 04/22/2013 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 4/22/2013 3:44:25 PM CALLED FPL TO RELEASE POWER AT 3:50 PM SPOKE WITH SUSAN approved by Mike Navarra | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 02/26/2013 | APPROVED | GLALIMA |
| LATH/BRICK/ WATER BARRIER | 01/24/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| LATH/BRICK/ WATER BARRIER | 01/22/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 1/22/2013 3:17:14 PM MISSING NAILS AND BANDING IN LATH approved by Mike Navarra | |||
| INSULATION | 01/15/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: approved by Mike Navarra Inspection Resulted at 1/15/2013 2:56:50 PM INSULATION OK | |||
| ELECTRIC - EARLY POWER | 01/14/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 1/14/2013 2:49:40 PM CALLED FPL TO RELEASE POWER AT 2:37 PM,SPOKE WITH SUSAN.GREEN PERFORMANCE ELEC | |||
| ALL ROUGH | 01/08/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 1/8/2013 3:45:28 PM DON FROM OLSON CALLED TO CANCEL passed as noted by Mike Navarra fire blocks at pool shower | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/04/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 1/4/2013 2:42:11 PM THIS WAS AN AUDIT..NEED REVISION FOR DETAIL K,GREAT RM AND LANAI KNEE WALL,DETAIL SHOWING ON BLOCK WALL.WORK DONE IS FRAMED WITH COIL STRAPPING. passed as noted by Mike Navarra strap E5 and 3B | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/26/2012 | AUDIT - PRIVATE PROVIDER INSPECTION | JMCGOWEN |
| Note: failed by Robert Waldrop renial sheathing | |||
| GRAVITY SEWER TEST | 12/07/2012 | AUDIT - PRIVATE PROVIDER INSPECTION | DROCKWELL |
| Note: Inspection Resulted at 12/7/2012 3:05:21 PM SEWER LINE COVERED CANNOT VIEW PIPE | |||
| U - SEWER TIE IN | 12/07/2012 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| ELEV CERT-FOUNDATION APPROVAL | 11/20/2012 | APPROVED | CBENTLEY |
| Note: THIS IS A REINSPECTION | |||
| TIE BEAM / LINTEL | 11/20/2012 | AUDIT - PRIVATE PROVIDER INSPECTION | DROCKWELL |
| Note: Inspection Resulted at 11/20/2012 2:17:52 PM LINTEL APPROVED approved by Mike Navarra | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/16/2012 | APPROVED | JHINDMAN |
| ELEV CERT-FOUNDATION APPROVAL | 11/16/2012 | Disapproved - NO FEE | CBENTLEY |
| Note: Section D Comments: Remove comment #2 or revise #2 so that the responsibility is that of the insurer not the City. | |||
| GRAVITY SEWER TEST | 11/05/2012 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 11/5/2012 1:15:20 PM THIS WAS AN AUDIT..NO TEST ON PIPE AND PIPE MOSTLY COVERED FBC.P.2503.2 -2503.4 | |||
| MONOLITHIC SLAB | 11/05/2012 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 11/5/2012 1:15:20 PM THIS WAS AN AUDIT..SLOPES ON FOOTERS SHOWING TO GO DOWN TO BOTTOM OF FOOTER AND LANAI FOOTER HAS NO SLOPE AT ALL. CHECK DETAIL C4 approved by Mike Navarra universal eng. | |||
| U - SEWER TIE IN | 11/05/2012 | Disapproved -FEE REQUIRED | KKING |
| Note: Inspection Resulted at 11/6/2012 1:59:23 PM TIE-IN POINT FULL OF WATER AND APPEARS TO HAVE A VERTICAL DROP WHICH IS NOT ALOWED. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/31/2012 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 10/31/2012 5:04:57 PM OK inspection passed by Larry Hites BN 5864 |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 06/12/2013 | 06/13/2013 |
| PLFM | HOLD | 06/12/2013 | 06/12/2013 |
| Note: 1. Provide comments for C2e item. 2. Remove comments from Section D. | |||
| ZON | COMPLETE | 06/06/2013 | 06/06/2013 |
| Note: Released By: JMCGOWEN finals survey | |||
| SW1 | COMPLETE | 06/06/2013 | 06/06/2013 |
| Note: Released By: JMCGOWEN finals survey | |||
| PLFM | HOLD | 06/06/2013 | 06/10/2013 |
| Note: 1. Revise section C1 to show finished construction 2. Revise Section D comment 2 by either removing the comment or change reviewer to insurer. 3. Remove Section D comment 3. FEMA autorizes the use of this form for insurance purposes. | |||
| ELEC | COMPLETE | 01/22/2013 | 01/22/2013 |
| DSD | COMPLETE | 11/20/2012 | 11/20/2012 |
| DSD | HOLD | 11/16/2012 | 11/16/2012 |
| Note: Held By: CBENTLEY Section D comments: Remove comment #2 or revise comment #2 so that the reviewer who is responsible for non-concurrency regading the diagram selection is the insurance agency and not the City. | |||
| ZON | COMPLETE | 11/16/2012 | 11/16/2012 |
| Note: Released By: JHINDMAN foundation survey | |||
| SW1 | COMPLETE | 11/16/2012 | 11/16/2012 |
| Note: Released By: JHINDMAN foundation survey | |||
| ELEC | COMPLETE | 10/17/2012 | 10/17/2012 |
| MECH | COMPLETE | 10/17/2012 | 10/17/2012 |
| ELEC | HOLD | 10/11/2012 | 10/11/2012 |
| Note: Revise receptacle locations to meet NEC 210.52 coordinate electric riser detail and electric load calculations as to what size the service will be FBC | |||
| MECH | HOLD | 10/11/2012 | 10/12/2012 |
| Note: Previous held comment need to be addressed - 1. Provide manufacturer, model number, sensible and total cooling capacities of the hvac units selected at the design conditions per 2010 FBC EC 403.6.1. | |||
| ZON | COMPLETE | 10/11/2012 | 10/16/2012 |
| BLD | COMPLETE | 10/11/2012 | 10/11/2012 |
| SW1 | COMPLETE | 10/11/2012 | 10/11/2012 |
| UD1 | COMPLETE | 10/11/2012 | 10/11/2012 |
| BLD | HOLD | 09/27/2012 | 10/05/2012 |
| Note: 1. Provide for hazardous location glazing per 2010FBC R 308.4. 2. Provide a non-bearing wall detail per 2010 FBC R 602.1.3. 3. Provide a lintel schedule 2010 FBC R 107.2.1. | |||
| ELEC | HOLD | 09/27/2012 | 09/28/2012 |
| Note: Revise receptacle locations to meet NEC 210.52 provide electric load calculations NEC article 220 | |||
| ENGIN1 | COMPLETE | 09/27/2012 | 09/27/2012 |
| MECH | HOLD | 09/27/2012 | 09/28/2012 |
| Note: 1. Provide manufacturer, model number, sensible and total cooling capacities of the hvac units selected at the design conditions per 2010 FBC EC 403.6.1. | |||
| PLUM | COMPLETE | 09/27/2012 | 09/28/2012 |
| SW1 | COMPLETE | 09/27/2012 | 09/28/2012 |
| URB | COMPLETE | 09/27/2012 | 09/28/2012 |
| ZON | HOLD | 09/27/2012 | 09/29/2012 |
| Note: Revise landscape plan to sho all trees included in Tree count on property. Per code required to have 13 trees. Revise color sheet to meet munsell. According to code light reflective value aka LRV is 30 or greater. LRv for trim is 24. Revise site plan to show side setbacks from the closes point of structure to the property line. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 06/11/2013 |
| REINSPECTION FEE | ¤40.00 | 06/11/2013 |
| NEW RESIDENTIAL INSPECTIONS | ¤690.00 | 10/18/2012 |
| SITE PLAN 20 | ¤20.00 | 10/18/2012 |
| SURCHARGE FS 533.721 | ¤2.47 | 10/18/2012 |
| SURCHARGE - FS 468.631 | ¤2.47 | 10/18/2012 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/18/2012 |
| TRANSPORTATION IMPACT FEE | ¤2,827.56 | 10/18/2012 |
| BUILDING DISCOUNT 100% | (¤1,484.10) | 10/18/2012 |
| ELECTRIC FEE | ¤267.00 | 10/18/2012 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/18/2012 |
| FIRE RESIDENTIAL IMPACT FEE | ¤198.38 | 10/18/2012 |
| MECHANICAL FEE | ¤267.00 | 10/18/2012 |
| PERMIT FEE | ¤20.00 | 10/18/2012 |
| PARKS IMPACT FEE | ¤1,281.86 | 10/18/2012 |
| PLAN CHECK FEE | ¤138.00 | 10/18/2012 |
| PLUMBING FEE | ¤267.00 | 10/18/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤8,257.64 |