I want to search for...
Permit #2012100305
Permit Details
Status: FINAL
| Parcel Id: 38-11-31-1915-00000-CA00 |
| COMMERCIAL SQUARE FOOTAGE: 912 sqft |
| Total Square Footage: 912 sqft |
| Block: 00000 |
| Subdivision: 2089 - EUROPEAN VILLAGE CONDO |
| Job Phone: (386) 547-0409 |
| Location Address: 101 PALM HARBOR PKWY |
| Type: CAS - COMMERCIAL ACCESSORY STRUCTURE |
| Issue Date: 11/01/2012 |
| NOC: RECORDED |
| Applicant name: BOHDAN HAWRYLUK |
| Owner: EUROPEAN VILLAGE CONDOMINIUM COMMON AREA |
|
Address 101 PALM HARBOR PKWY PALM COAST, FL 32137 |
| Lot: CA00 |
| Contracted Stated Job Value: ¤27,000.00 |
| Job Description: GAZEBO ROOF STRUCTURE OVER EXISTING STEEL PAVILLION - COURTYARD/COMMON AREA |
| Type: CN |
Contractor
INTERCOASTAL CONSTRUCTION CO.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
14 SLIPPER ORCHID TRAIL EAST PALM COAST, FL 32164 |
CBC035048 (Exp: 08/31/2024) | (386) 547-0409 | 386-673-8868 |
Inspection History
| Type | Request Date | Result | Inspector |
| ACCESSORY FINAL | 02/14/2013 | APPROVED | JHINDMAN |
| Note: requested by contractor | |||
| FINAL | 02/14/2013 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 02/14/2013 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 12/21/2012 | Disapproved - NO FEE | JHINDMAN |
| Note: Inspection Requested at 12/20/2012 9:53:44 PM PERMIT SAYS 5250 Inspection Resulted at 12/21/2012 3:18:05 PM 1.FILL IN TRENCH IN FLOOR 2010 FBC ACCESSIBILITY 302.3. 2.REMOVE OLD WIRING FROM CONDUIT 2008 NEC 110.12 C. | |||
| FINAL | 12/21/2012 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 12/21/2012 3:18:06 PM 1. FILL IN TRENCH IN FLOOR 2010 FBC ACCESSIBILITY 302.3 2. REMOVE OLD WIRING FROM CONDUIT 2008 NEC 110.12 C. | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 11/28/2012 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/29/2012 | 10/30/2012 |
| BLD | HOLD | 10/12/2012 | 10/15/2012 |
| Note: 1.Provide an engineers evaluation of the existing structure per 2010 FBC 107.1. 2. Provide a site specific plan that references and is designed for the 2010 Florida Building Code. 3. This plan is for work that is outside of the scope of an Architects license. Per 481 Florida State Statutes. 4. The plan is required to be signed and sealed by a Florida engineer. Per 471 Florida State Statutes. 5. The plan must indicate all design loads, including the uplifts along with the connections to the existing structure. 2010 FBC 107.1. 6. Provide a letter of authorization from the European Commercial Condo Association for the work to be done. Per AHJ | |||
| DSD | COMPLETE | 10/12/2012 | 10/12/2012 |
| ELEC | COMPLETE | 10/12/2012 | 10/12/2012 |
| Note: no electric on this permit | |||
| ENGIN1 | COMPLETE | 10/12/2012 | 10/12/2012 |
| FI1 | COMPLETE | 10/12/2012 | 10/12/2012 |
| SW1 | COMPLETE | 10/12/2012 | 10/12/2012 |
| UD1 | COMPLETE | 10/12/2012 | 10/12/2012 |
| ZON | COMPLETE | 10/12/2012 | 10/12/2012 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECT - SHD,APO,FN | ¤20.00 | 02/13/2013 |
| SITE PLAN 20 | ¤20.00 | 11/01/2012 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/01/2012 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/01/2012 |
| ADMIN COMMERCIAL | ¤60.00 | 11/01/2012 |
| BUILDING DISCOUNT 100% | (¤314.10) | 11/01/2012 |
| PERMIT FEE | ¤189.00 | 11/01/2012 |
| PLAN CHECK FEE | ¤100.00 | 11/01/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤78.90 |