I want to search for...
Permit #2012110185
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01580-0010 |
| CONDITIONED SPACE: 2301 sqft |
| GARAGE: 487 sqft |
| SCREEN PORCH (SOLID ROOF) : 240 sqft |
| PATIO/DECK (NO ROOF) : 274 sqft |
| Total Square Footage: 3302 sqft |
| Block: 01580 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-672-6101 |
| Location Address: 171 ERIC DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/28/2012 |
| NOC: RECORDED |
| Applicant name: JOHN DAVID MINABERRY |
| Owner: LARSEN JACK & KAREN H&W |
|
Address 11401 W HWY 316 REDDICK, FL 32686 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤256,670.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KEYSTONE HOMES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1339 W GRANADA BLVD ORMOND, FL 32174 |
CRC1329222 (Exp: 08/31/2026) | 386-672-6101 | 386-672-6102 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone |
| CANCEL |
17 UNIMAY CT BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2022) | 386-931-2568 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
DAVID CASH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
45 SOUTH DIXIE HIGHWAY ST. AUGUSTINE, FL 32084 |
01613 (Exp: 08/31/2014) | (386)437-3433 | 904-829-1844 |
DAVID CASH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
45 SOUTH DIXIE HIGHWAY ST. AUGUSTINE, FL 32084 |
01613 (Exp: 08/31/2014) | (386)437-3433 | 904-829-1844 |
WAYNE A PHILLIPS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
357 ANDREWS ST ORMOND BEACH, FL 32174 |
CVC56698 (Exp: 08/31/2026) | (386)673-9720 | (386)673-9840 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 07/03/2013 | FINAL APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 07/02/2013 | APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 07/01/2013 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 06/27/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 6/27/2013 2:50:16 PM NOT READY FOR INSPECTION. MISSING SINK HOOK UP IN LAUNDRY ROOM. | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 06/26/2013 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: TOOK 8 PHOTOS FILL IN ON LEFT SIDE OF PROPERTY LINE TO BLEND 2 TO 1 SLOPE. REMOVE ALL TRASH FROM CENTER OF DRAINAGE DITCH ''' I . E 4" PVC PIPE CUTS OF 2 X 4 CUPS AND ALL OTHER. REMOVE 3 PILES OF FILL FORM CENTER OF DITCH AT BACK CORNER OF HOUSE , REMOVE TOILET FROM VACANT LOT LEFT '' SWALE '' SO WE CAN ASSESS DAMAGE . REMOVE 2 X 4' X 8' ON VACANT LOT LEFT ... CLEAN EDGE OF ROAD ON VACANT LEFT SO WE CAN ASSESS DAMAGE IF NEEDED , AT TODS IINSPECTION WE HAD 1 TRUCK 1 VAN AND 2 CARS . UNABLE SEE THIS . REINSPECTIONS NEEDED | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/25/2013 | APPROVED | JMCGOWEN |
| ELECTRIC - EARLY POWER | 06/04/2013 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 6/4/2013 3:13:44 PM DB ELECTRIC. CALLED FPL AT 145 | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 06/04/2013 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| U - SEWER TIE IN | 05/16/2013 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| GRAVITY SEWER TEST | 05/14/2013 | APPROVED | RMARVEL |
| U - SEWER TIE IN | 05/13/2013 | Disapproved - NO FEE | DSPENCER |
| Note: Inspection Resulted at 5/13/2013 9:19:47 AM UNCOVER AND REPLACE CLEANOUT | |||
| LATH/BRICK/ WATER BARRIER | 04/08/2013 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 04/05/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 04/05/2013 | APPROVED | CMINI |
| LATH/BRICK/ WATER BARRIER | 04/05/2013 | CANCELLED BY APPLICANT | CMINI |
| ALL ROUGH | 03/28/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 3/28/2013 12:36:47 PM ELECTRICAL DOES NOT MATCH PLANS. MISSING SMOKE DETECTOR. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/18/2013 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/14/2013 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 3/14/2013 3:40:54 PM MISSED 2 CELLS ON BACK PORCH THAT NEED TO BE POURED. MISSING ENGINEERING ON 05 AND 6 TRUSSES. MISSING H6 ON FRONT PORCH. FOUND LOOSE SHEATHING ON ROOF. RECHECK FOR SHINERS AND NAIL PER APPROVED PLANS. FBC 107.2.1 LOOSE ANCHOR BOLTS ON WALL TO BLOCK CONNECTION. RECHECK PLACEMENT OF BOLTS SPACING. PER PLANS. ADD NAIL ON SP-1 AND SP-2 AT 45 DEGREE ANGLE PER MANUFACTURER SPECIFICATIONS. | |||
| ELECTRIC TEMP POLE | 03/14/2013 | APPROVED | RMARVEL |
| Note: called fpl at 3?:30 | |||
| ELECTRIC - EARLY POWER | 03/14/2013 | CANCELLED BY INSPECTOR | RMARVEL |
| Note: wrong inspection called. it needs to be a temp power pole. added that inspection same day as this inspection. | |||
| TIE BEAM / LINTEL | 02/21/2013 | APPROVED | RMARVEL |
| FOUND SURVEY APPROVED (OFFICE) | 02/18/2013 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 02/08/2013 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/05/2013 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 06/25/2013 | 06/25/2013 |
| Note: Released By: JMCGOWEN final survey | |||
| ZON | COMPLETE | 06/25/2013 | 06/25/2013 |
| Note: Released By: JMCGOWEN final survey | |||
| ELEC | COMPLETE | 04/03/2013 | 04/04/2013 |
| BLD | COMPLETE | 03/12/2013 | 03/12/2013 |
| ZON | COMPLETE | 02/18/2013 | 02/18/2013 |
| Note: Released By: FREODICA foundation survey | |||
| SW1 | COMPLETE | 02/18/2013 | 02/18/2013 |
| Note: Released By: FREODICA foundation survey | |||
| SW1 | COMPLETE | 12/12/2012 | 12/12/2012 |
| MECH | COMPLETE | 12/12/2012 | 12/12/2012 |
| UD1 | COMPLETE | 12/05/2012 | 12/06/2012 |
| ELEC | COMPLETE | 12/05/2012 | 12/05/2012 |
| SW1 | HOLD | 12/05/2012 | 12/05/2012 |
| Note: Revise site plan to show positive drainage and locate gas tank locating LDC | |||
| MECH | HOLD | 12/05/2012 | 12/05/2012 |
| Note: Previous review comments below on gas need to be addressed. 3. Provide location of gas tank and piping layout on site plan and coordinate with riser diagram for clarity per 2010 FBC 107.2.1. 4. On riser diagram, provide tracer wire, size and type per 2010 FBC FG Section 404.15.3, pipe size, material specification for indoor use and approximate distances between appliances per 2010 FBC FG Section 402. | |||
| BLD | COMPLETE | 12/05/2012 | 12/05/2012 |
| ZON | COMPLETE | 12/05/2012 | 12/07/2012 |
| BLD | HOLD | 11/08/2012 | 11/09/2012 |
| Note: 1. Provide location of outdoor kitchen and details on floor plan in coordination with plumbing and gas riser diagrams for clarity per 2010 FBC 107.2.1. 2. Provide manufacturer's specification and installation instructions for fire fireplace per 2010 FRC M1801.1 3. Provide exterior wall covering information per 2010 FRC Section R703.6. 4. Provide evaluation report on spray foam insulation specifications, thickness required and method of application for unvented attic per 2010 FBC 107.2.1/FRC R806.4. | |||
| ELEC | HOLD | 11/08/2012 | 11/09/2012 |
| Note: Provide transfer switch cut sheet, provide pep tank disconnect location, provide service riser detail include conductor sizes FBC 107.2.1 | |||
| ENGIN1 | COMPLETE | 11/08/2012 | 11/13/2012 |
| MECH | HOLD | 11/08/2012 | 11/09/2012 |
| Note: 1. Number of bedrooms on energy calculations does not match with floor plan. Coordinate and revise per 2010 FBC 107.2.1. 2. Hvac plan shall have signature of hvac contractor per 2010 FBC 107.3.4.3. 3. Provide location of gas tank and piping layout on site plan and coordinate with riser diagram for clarity per 2010 FBC 107.2.1. 4. On riser diagram, provide tracer wire, size and type per 2010 FBC FG Section 404.15.3, pipe size, material specification for indoor use and approximate distances between appliances per 2010 FBC FG Section 402. | |||
| PLUM | COMPLETE | 11/08/2012 | 11/09/2012 |
| SW1 | HOLD | 11/08/2012 | 11/09/2012 |
| Note: Revise site plan to show positive drainage and locate gas tank locating FBC 107.2.1 | |||
| UD1 | HOLD | 11/08/2012 | 11/09/2012 |
| Note: pep panel must be shown on the electrical plan and must be withen 3' of front corner same side as the utility site plan for the tank | |||
| URB | COMPLETE | 11/08/2012 | 11/09/2012 |
| ZON | HOLD | 11/08/2012 | 11/14/2012 |
| Note: Revise site plan to provide the location of the gas tank. Revise site plan to remove the a/c pad out of the easement. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/02/2013 |
| REINSPECTION FEE | ¤40.00 | 07/02/2013 |
| REINSPECTION FEE | ¤40.00 | 07/02/2013 |
| REVISION | ¤40.00 | 07/02/2013 |
| REVISION | ¤40.00 | 07/02/2013 |
| SITE PLAN 20 | ¤20.00 | 12/28/2012 |
| SURCHARGE FS 533.721 | ¤20.89 | 12/28/2012 |
| SURCHARGE - FS 468.631 | ¤20.89 | 12/28/2012 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/28/2012 |
| TRANSPORTATION IMPACT FEE | ¤2,827.56 | 12/28/2012 |
| NEW RESIDENTIAL INSPECTIONS | ¤568.00 | 12/28/2012 |
| ADMIN FEE | ¤20.00 | 12/28/2012 |
| ELECTRIC FEE | ¤230.40 | 12/28/2012 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 12/28/2012 |
| FIRE RESIDENTIAL IMPACT FEE | ¤198.38 | 12/28/2012 |
| MECHANICAL FEE | ¤230.40 | 12/28/2012 |
| PERMIT FEE | ¤20.00 | 12/28/2012 |
| PARKS IMPACT FEE | ¤1,281.86 | 12/28/2012 |
| PLAN CHECK FEE | ¤113.60 | 12/28/2012 |
| PLUMBING FEE | ¤230.40 | 12/28/2012 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,662.38 |