I want to search for...

Permit #2012110552

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-1740
CONDITIONED SPACE: 2162 sqft
GARAGE: 443 sqft
OPENED PORCH (WITH ROOF) : 505 sqft
PATIO/DECK (NO ROOF) : 36 sqft
Total Square Footage: 3146 sqft
Block: 00000
Subdivision: 2094 - Conservatory at Hammock Beach
Job Phone: (386) 446-5850
Location Address: 405 BOURGANVILLE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/17/2012
NOC: RECORDED
Applicant name: CHARLES DALLAS RINEK
Owner: NEWSONE DARRELL G & LORI A NEWSONE H&W

Address

7279 AZALEA DRIVE SE

GRAND RAPIDS, MI 49508

Lot: 1740
Contracted Stated Job Value: ¤289,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CHARLES RINEK CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 352502

Palm Coast, FL 32137

CGC046080 (Exp: 08/31/2026) (386) 446-5850 (386)445-9992

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156
BOB BELL
Status Location Address State License Number Phone
CANCEL

411 6TH STREET

HOLLY HILL, FL 32117

01612 (Exp: 09/18/2014) 386-252-5555
PHILIP ALAN KENOVICH
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 1470

HOLLY HILL, FL 32117

LG270 (Exp: 08/31/2026) (386)672-2507

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 07/29/2013 FINAL APPROVED KKING
Note: requested by contractor
BLD - BUILDING FINAL 07/26/2013 APPROVED DROCKWELL
GAS FINAL 07/25/2013 APPROVED DROCKWELL
FINAL SURVEY (OFFICE USE ONLY) 07/15/2013 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 05/31/2013 APPROVED DROCKWELL
U - SEWER TIE IN 05/24/2013 APPROVED KKING
LATH/BRICK/ WATER BARRIER 03/06/2013 APPROVED DROCKWELL
GAS ROUGH 03/01/2013 APPROVED DROCKWELL
INSULATION 03/01/2013 APPROVED DROCKWELL
ALL ROUGH 02/25/2013 APPROVED DROCKWELL
ALL ROUGH 02/20/2013 CANCELLED BY APPLICANT AIRS WEB
ELECTRIC-TUG 02/13/2013 APPROVED DROCKWELL
GRAVITY SEWER TEST 02/13/2013 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/05/2013 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 2/5/2013 2:52:57 PM REVISE PLANS TO SHOW SP``S NOT NEEDED AT BEARING WALL IF THREADED RODS ARE INSTALLED.DETAIL CONFLICS WITH TRUSS LAY-OUT FLOOR PLAN.
TIE BEAM / LINTEL 01/18/2013 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 01/17/2013 APPROVED JHINDMAN
MONOLITHIC SLAB 01/07/2013 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 01/03/2013 APPROVED CMINI

Review History

Department Status Date In Date Out
PLUM COMPLETE 07/23/2013 07/23/2013
Note: Revision - changed gas contractor and gas riser diagram.
ZON COMPLETE 07/15/2013 07/15/2013
Note: Released By: JHINDMAN final survey
SW1 COMPLETE 07/15/2013 07/15/2013
Note: Released By: JHINDMAN final survey
URB COMPLETE 06/05/2013 06/06/2013
SW1 COMPLETE 06/05/2013 06/05/2013
BLD COMPLETE 05/24/2013 05/24/2013
ENGIN1 COMPLETE 05/24/2013 05/28/2013
Note: No swale plan required.
SW1 COMPLETE 05/24/2013 05/24/2013
UD1 COMPLETE 05/24/2013 05/24/2013
Note: the meter pit in question is the HOA's responsibility not the City Utilities. Keith King 386-9318009
URB HOLD 05/24/2013 05/28/2013
Note: Need to add 1 understory tree or another shade tree this lot requires 3 code trees palms cannot be used for more then 25% of the total tree credits.
ZON COMPLETE 05/24/2013 05/31/2013
ZON COMPLETE 02/26/2013 02/26/2013
BLD COMPLETE 02/22/2013 02/25/2013
PLUM COMPLETE 02/22/2013 02/25/2013
SW1 COMPLETE 02/22/2013 02/25/2013
ZON HOLD 02/22/2013 02/22/2013
Note: Revise site plan to show proposed setbacks and dimension of proposed gas tank.
ELEC COMPLETE 02/21/2013 02/22/2013
ELEC HOLD 02/20/2013 02/20/2013
Note: Held By: BBEMBRY 1. Provide plan revisions which have been signed and sealed by the original design professional.
MECH COMPLETE 02/15/2013 02/18/2013
Note: Revision- changed insulation - open cell, unvented attic.
BLD COMPLETE 02/15/2013 02/15/2013
BLD COMPLETE 02/07/2013 02/07/2013
BLD COMPLETE 02/06/2013 02/06/2013
BLD HOLD 02/04/2013 02/04/2013
Note: Clarify and provide illustration, detail of anchor system to be used FBC 107.2.1
ZON COMPLETE 01/17/2013 01/17/2013
Note: Released By: JHINDMAN foundation survey
SW1 COMPLETE 01/17/2013 01/17/2013
Note: Released By: JHINDMAN
PLUM COMPLETE 01/04/2013 01/04/2013
Note: Revision - relocated water heater.
BLD COMPLETE 12/21/2012 12/26/2012
BLD COMPLETE 12/12/2012 12/12/2012
ELEC COMPLETE 12/12/2012 12/14/2012
ELEC HOLD 12/07/2012 12/07/2012
Note: provide electrician’s license number and name of qualifier on load calculation FBC 107.1
PLUM COMPLETE 12/07/2012 12/07/2012
MECH COMPLETE 12/07/2012 12/07/2012
BLD HOLD 12/07/2012 12/07/2012
Note: 1. Provide an exterior wall finish that complies with ASTM C 926 per 2010 FBC R703.6. 2. Provide a complete manufacturers specifications for the fireplace 2010 FBC R 1801.1.
ZON COMPLETE 12/07/2012 12/11/2012
BLD HOLD 11/29/2012 11/29/2012
Note: 1. revise general note 1. on the general note sheet to the current code. Florida statutes. 2. Provide an exterior wall finish that complies with ASTM C 926 per 2010 FBC R703.6. 3.Provide Florida Product approval and installation instructions for the roofing, exterior doors, overhead garage door, and windows. 2010 FBC 107.2.1. 4. provide a non-bearing wall detail. 2010 FBC R 602.1.3. 5. Provide a garage to house door that complies with 2010 FBC 302.5.1. 6. provide a gas riser diagram for the fireplace. 2010 FFGC ch 4. 7. Provide manufacturers specifications for the fireplace. 2010 FBC R 1801.1.
ELEC HOLD 11/29/2012 11/29/2012
Note: Revise receptacle location to meet NEC 210.52 provide electric load calculations provide service conductor sizes FBC 107.2.1
ENGIN1 COMPLETE 11/29/2012 11/30/2012
MECH HOLD 11/29/2012 11/29/2012
Note: 1. Provide gas riser diagram for gas fireplace and gas contractor per 2010 FBC 107.2.1. 2. Provide signature of builder on EPL Dispaly Card of energy calculation per 2010 FBC EC 405.4.3.
PLUM HOLD 11/29/2012 11/29/2012
Note: Provide sanitary riser diagram including material specification with signature and license number of plumbing contractor or a design professional per 2010 FBC 107.2.1.
SW1 COMPLETE 11/29/2012 11/29/2012
UD1 COMPLETE 11/29/2012 11/30/2012
URB COMPLETE 11/29/2012 12/03/2012
ZON HOLD 11/29/2012 12/04/2012
Note: Revise site plan to courtyard from setback on right side. Revise site and building plans to remove easement from sides they are sebacks. Revise site and landscape to be constant. Paver Courtyard vs. landscape courtyard. Revise color sheet to show garage door color.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 07/24/2013
REVISION ¤40.00 07/24/2013
REVISION ¤40.00 02/27/2013
REVISION ¤40.00 02/22/2013
REVISION ¤40.00 02/18/2013
REVISION ¤40.00 02/11/2013
REVISION ¤40.00 02/07/2013
REVISION ¤40.00 01/04/2013
REVISION ¤40.00 01/03/2013
ADMIN FEE ¤20.00 12/17/2012
ELECTRIC FEE ¤233.40 12/17/2012
IMPACT FEE SCHOOL ¤3,600.00 12/17/2012
FIRE RESIDENTIAL IMPACT FEE ¤198.38 12/17/2012
MECHANICAL FEE ¤233.40 12/17/2012
PARKS IMPACT FEE ¤1,281.86 12/17/2012
PLAN CHECK FEE ¤115.60 12/17/2012
PLUMBING FEE ¤233.40 12/17/2012
NEW RESIDENTIAL INSPECTIONS ¤578.00 12/17/2012
SITE PLAN 20 ¤20.00 12/17/2012
SURCHARGE FS 533.721 ¤21.21 12/17/2012
SURCHARGE - FS 468.631 ¤21.21 12/17/2012
STORM WATER PERMIT FEES ¤80.00 12/17/2012
TRANSPORTATION IMPACT FEE ¤2,827.56 12/17/2012
Fees Total Due: ¤0.00 Total Paid: ¤9,824.02