I want to search for...

Permit #2012120193

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00070-0440
CONDITIONED SPACE: 1144 sqft
CONDITIONED SPACE: 1144 sqft
GARAGE: 324 sqft
GARAGE: 324 sqft
OPENED PORCH (WITH ROOF) : 98 sqft
OPENED PORCH (WITH ROOF) : 98 sqft
PATIO/DECK (NO ROOF) : 70 sqft
PATIO/DECK (NO ROOF) : 70 sqft
Total Square Footage: 3272 sqft
Block: 00070
Subdivision: 2137 - SECTION 10-FLORIDA PARK
Job Phone: (386)445-9055
Location Address: 87 FIELDSTONE LN
Type: DU - DUPLEX
Issue Date: 01/31/2013
NOC: RECORDED
Applicant name: LUIS JORGE MEDEIROS
Owner: SILVA, VERGILIO H & JESSICA I

Address

90 MAYBURY STREET

CUMBERLAND, RI 02864

Lot: 0440
Contracted Stated Job Value: ¤169,900.00
Job Description: DUPLEX
Type: CN

Contractor

NEW COASTAL HOMES INC.
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

399 SW PALM COAST PKWY

PALM COAST, FL 32137

STE5

PALM COAST, FL 32137

CRC1327024 (Exp: 08/31/2018) (386)445-9055 (386)445-9056

Sub Contractors

CHARLES K DAVIS
Status Location Address State License Number Phone
ACTIVE

3000 E MOODY BLVD BLDG 2

BUNNELL , FL 32110

EC13004270 (Exp: 08/31/2026) 386-931-6614
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/03/2014 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
FINAL APRON (AFTER POUR/DRIVEWAY) 03/03/2014 APPROVED RGROSS
U -UTILITY RESIDENTIAL FINAL 03/03/2014 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 02/28/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 2/28/2014 2:45:42 PM FINAL SURVEY NEEDS TO BE APPROVED AND ON SITE FOR INSPECTION..ALL ELSE OK
FINAL SURVEY (OFFICE USE ONLY) 02/28/2014 APPROVED FREODICA
PRE-APRON (PRE-POUR/DRIVEWAY) 01/13/2014 APPROVED - AS NOTED RGROSS
Note: DRIVEWAY SHOULDERS FULL OF WATER. PUMP WATER OUT BEFORE POURING. ALSO BECAUSE THE DIRT AND MATERIAL IS SOFT FROM THE RAIN WATER DOUBLE CHECK THE PIPE ELEVATIONS BEFORE POURING.
GRAVITY SEWER TEST 12/09/2013 APPROVED CMINI
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 12/06/2013 APPROVED DSPENCER
ELECTRIC - EARLY POWER 11/12/2013 APPROVED DROCKWELL
LATH/BRICK/ WATER BARRIER 08/27/2013 APPROVED RMARVEL
INSULATION 08/21/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 08/19/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: OK PER JOE MCOWEN Inspection Resulted at 8/19/2013 11:19:14 AM ROOF LEAKS AT HOOD EXHAUST THRU ROOF BOTH SIDES-REPLACE WET INSULATION BOTH SIDES.CANNOT DRYWALL UNTIL ROOF IS TIGHT,
ALL ROUGH 08/13/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ALL ROUGH 08/12/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 8/12/2013 12:51:21 PM COMPLETE ELEC. PANEL WORK/STRAP WIRE WITHIN 12IN OF PANEL/ADD LIGHTING PER PLAN IN KITCHEN MISSING ATTIC LIGHTS BOTH SIDES.SHOW PROPER PANEL LOCATION IN GARAGE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/24/2013 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 5/24/2013 12:28:16 PM RIGHT SIDE- NAIL TRUSS TO BUCKET H13/HG5C STRAP NOT NAILED/H15 H17 NOT NAILED TO STRAP MIDPOINT/ LEFT SIDE-H15 H17 NOT NAILED TO STRAP MID POINT/CJ3C NOT STRAPPED EITHER SIDE/COVER EXPOSED WOOD AT FIREWALL WITH TYPE X /FINISH DRYWALL COMPOUND AT JOINTS BOTH SIDES.WILL CHECK AT ALL ROUGH
TIE BEAM / LINTEL 04/08/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 04/04/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 4/4/2013 12:02:14 PM STEEL NOT TO PLAN-SEE C.M.U WALL TRANSITION DETAIL ON PLAN
FOUND SURVEY APPROVED (OFFICE) 04/03/2013 APPROVED JHINDMAN
GRAVITY SEWER TEST 03/28/2013 CANCELLED BY APPLICANT CMINI
MONOLITHIC SLAB 03/18/2013 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 03/14/2013 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
ZON COMPLETE 02/28/2014 02/28/2014
Note: Released By: FREODICA
SW1 COMPLETE 01/14/2014 01/14/2014
ZON COMPLETE 01/14/2014 01/14/2014
ELEC COMPLETE 08/13/2013 08/14/2013
ZON COMPLETE 04/02/2013 04/02/2013
Note: Released By: JHINDMAN foundation survey
SW1 COMPLETE 04/02/2013 04/02/2013
Note: Released By: JHINDMAN foundation survey
URB COMPLETE 01/23/2013 01/23/2013
BLD COMPLETE 01/23/2013 01/23/2013
MECH COMPLETE 01/23/2013 01/23/2013
ELEC COMPLETE 01/23/2013 01/23/2013
ZON COMPLETE 01/23/2013 01/23/2013
BLD HOLD 12/13/2012 12/13/2012
Note: 1.The tenant seperation wall detail has a roof gable truss on top of the cmu wall. The truss layout and engineering does not show a truss at that location. Provide a corrected detail or layout with engineering. 2010 FBC R 107.2.1 and 302.3.
ELEC HOLD 12/13/2012 12/13/2012
Note: 1. Provide outlet and switch for disposal per 2010 FBC 107.2.1. 2. Provide identification for 3-way switch per 2010 FBC 107.2.1. Reviewed by LWoodrom3 12/13/12
ENGIN1 COMPLETE 12/13/2012 12/18/2012
MECH HOLD 12/13/2012 12/13/2012
Note: 1. House orientation shown on energy calculations does not match with orientation shown on site plan. Revise and coordinate to comply with 2010 FBC 107.2.1.
PLUM COMPLETE 12/13/2012 12/13/2012
SW1 COMPLETE 12/13/2012 12/13/2012
UD1 COMPLETE 12/13/2012 12/13/2012
URB HOLD 12/13/2012 12/13/2012
Note: If using st. augustine sod or any non-drought type a permanent irrigation system must be installed and stated on the plan.
ZON HOLD 12/13/2012 12/18/2012
Note: Provide an updated boundary survey with the correct Flood Map Firm Panel.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/03/2014
REINSPECTION FEE ¤40.00 03/03/2014
REINSPECTION FEE ¤40.00 03/03/2014
REINSPECTION FEE ¤40.00 03/03/2014
REVISION ¤40.00 03/03/2014
SITE PLAN 20 ¤20.00 01/31/2013
SURCHARGE FS 533.721 ¤20.77 01/31/2013
SURCHARGE - FS 468.631 ¤20.77 01/31/2013
STORM WATER PERMIT FEES ¤80.00 01/31/2013
TRANSPORTATION IMPACT FEE ¤2,926.54 01/31/2013
TRANSPORTATION IMPACT FEE ¤2,926.54 01/31/2013
NEW RESIDENTIAL INSPECTIONS ¤564.00 01/31/2013
ADMIN FEE ¤20.00 01/31/2013
ELECTRIC FEE ¤229.20 01/31/2013
IMPACT FEE SCHOOL ¤3,600.00 01/31/2013
IMPACT FEE SCHOOL ¤3,600.00 01/31/2013
FIRE RESIDENTIAL IMPACT FEE ¤198.38 01/31/2013
FIRE RESIDENTIAL IMPACT FEE ¤198.38 01/31/2013
MECHANICAL FEE ¤229.20 01/31/2013
PARKS IMPACT FEE ¤1,281.86 01/31/2013
PARKS IMPACT FEE ¤1,281.86 01/31/2013
PLAN CHECK FEE ¤112.80 01/31/2013
PLUMBING FEE ¤229.20 01/31/2013
Fees Total Due: ¤0.00 Total Paid: ¤17,739.50