I want to search for...

Permit #2012120331

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7025-00710-0210
CONDITIONED SPACE: 313 sqft
Total Square Footage: 313 sqft
Block: 00710
Subdivision: 2189 - SECTION 25-PINE GROVE
Job Phone: 386-503-0906
Location Address: 8 PALMER LN
Type: BA - BUILDING ADDITION
Issue Date: 01/14/2013
NOC: RECORDED
Applicant name: ANTHONY FALLONE
Owner: NUNEZ BIENVENIDO & LINDA H&W

Address

8 PALMER LANE

PALM COAST, FL 32164

Lot: 0210
Contracted Stated Job Value: ¤18,000.00
Job Description: REMOVE EXCESSIVE CONCRETE OUT OF EASEMENT & 18.4 X 17 ROOM ADDITION & MASTER BATH W/ 2X3 & 3X5 PAD
Type: CN

Contractor

FONTANA CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 351222

PALM COAST, FL 32137

CBC1250596 (Exp: 08/31/2022) 386-503-0906 (386)986-1305

Sub Contractors

RICHARD R EDWARDS
Status Location Address State License Number Phone
CANCEL

P. O. Box 1637

Bunnell, FL 32110

ER0011603 (Exp: 08/31/2022) (386) 437-1537
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156

Inspection History

Type Request Date Result Inspector
FOUND SURVEY APPROVED (OFFICE)
FINAL SURVEY (OFFICE USE ONLY)
PLUMBING 1ST ROUGH UNDERGROUND
MONOLITHIC SLAB
ALL ROUGH
ROOF SHEATHING / BRACES/TIES/DOWN CELL
INSULATION
BLD - BUILDING FINAL
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 01/11/2013 01/11/2013
ZON COMPLETE 01/11/2013 01/14/2013
ELEC COMPLETE 01/04/2013 01/04/2013
BLD HOLD 01/04/2013 01/04/2013
Note: 1. The origional plan page includes details that are not on the new plan. You cannot have two pages with different floorplans. 2010 FBC 107.2.1.
ZON HOLD 01/04/2013 01/07/2013
Note: 1. There are inconsistencies in the depictions of various proposed and/or existing concrete slabs at the rear and side of the home when comparing the Revised Site Plan and latest Floor Plan. Please revise the Site Plan and/or Floor Plan to match and to accurately show locations of all new or remaining concrete slabs in these areas. 2. If revisions to the site plan for the new or remaining concrete slabs create a corresponding change in the impervious areas on the Revised Site Plan, please also revise the impervious areas stated on the site plan. 3. Per Section 13.02.06, please provide information on the paint colors and manufacturers for evaluation of paint colors of both the main wall surfaces and all trims, which must meet Munsell color system. Please provide both the manufacturer (Colorwheel, Benjamin Moore, Sherwin Williams, etc) and the numerical code and name of the paint colors to be used. 4. Please include tree count and tree locations on the site plan. There must be four (4) total trees on the property per LDC Section 11.03.01., two of which must be located in the front of the house and two of which must be located in the rear.
BLD HOLD 12/20/2012 12/21/2012
Note: 1. provide florida product approval and installation instructions for the light tunnels. 2010 FBC 107.2.1. 2. Identify the existing bedrooms new use. It cannot remain a bedroom per city of Palm Coast property maintenance code sec. 15-119 c 3.
ELEC HOLD 12/20/2012 12/21/2012
Note: 1. Provide electrical load calculations which include addition. FBC 107.2.1 2. Provide electrical riser diagram. FBC 107.2.1 3. Provide service receptacle within 25 ' of air conditioner condensing unit. NEC 210.63
MECH COMPLETE 12/20/2012 12/21/2012
PLUM COMPLETE 12/20/2012 12/21/2012
SW1 COMPLETE 12/20/2012 12/21/2012
ZON HOLD 12/20/2012 12/21/2012
Note: 1. Revise site plan to show existing and proposed total impervious area on the site. Impervious area cannot exceed 75 percent. 2. Please revise the site plan to depict the parking space constructed to the right side of the driveway, and show as concrete to be removed. 3. Please revise the site plan to show removal of the existing 9' x 12' concrete slab that encroaches the easement on the left side of the residence.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 01/14/2013
ELECTRIC FEE ¤80.40 01/14/2013
MECHANICAL FEE ¤80.40 01/14/2013
PLAN CHECK FEE ¤40.00 01/14/2013
PLUMBING FEE ¤80.40 01/14/2013
REMODEL/ADDITION/ACCES INSPECT ¤40.00 01/14/2013
SITE PLAN 20 ¤20.00 01/14/2013
SURCHARGE FS 533.721 ¤5.12 01/14/2013
SURCHARGE - FS 468.631 ¤5.12 01/14/2013
STORM WATER PERMIT FEES ¤80.00 01/14/2013
Fees Total Due: ¤0.00 Total Paid: ¤451.44