Permit #2013010644

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00150-0020
CONDITIONED SPACE: 2545 sqft
GARAGE: 503 sqft
SCREEN PORCH (SOLID ROOF) : 409 sqft
PATIO/DECK (NO ROOF) : 146 sqft
Total Square Footage: 3603 sqft
Block: 00150
Subdivision: -
Job Phone: (386)446-5161
Location Address: 6 WHITFIELD PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/21/2013
NOC: RECORDED
Applicant name: HUGO A CAMACHO
Owner: MONTEIRO, LUIS & FERNANDA

Address

11 SANDERS LANE

STOUGHTON, MA 02072

Lot: 0020
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

IDEAL HOMES AT PALM COAST, INC.
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 353639

PALM COAST, FL 32137

CBC1250774 (Exp: 08/31/2026) (386)446-5161 (386)447-0238

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
RYSZARD ALOJZY SKLADZIEN
Status Location Address State License Number Phone Fax
CANCEL

2 MARKET PLACE UNIT D

PALM COAST, FL 32137

CCC057546 (Exp: 08/31/2016) (386)445-7945 (386)446-3871

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/07/2014 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 01/06/2014 FINAL APPROVED CMINI
FINAL SURVEY (OFFICE USE ONLY) 11/18/2013 APPROVED FREODICA
FINAL APRON (AFTER POUR/DRIVEWAY) 11/06/2013 APPROVED RGROSS
ROW FINAL 11/06/2013 FINAL APPROVED RGROSS
PRE-APRON (PRE-POUR/DRIVEWAY) 10/03/2013 APPROVED RGROSS
Note: THIS IS A REINSPECTION
PRE-APRON (PRE-POUR/DRIVEWAY) 10/02/2013 Disapproved - NO FEE RGROSS
Note: No Swale Sheet on site
ELECTRIC - EARLY POWER 09/24/2013 APPROVED - AS NOTED RMARVEL
Note: Inspection Resulted at 9/24/2013 2:50:12 PM CALLED FPL AT 2:45
GRAVITY SEWER TEST 08/08/2013 APPROVED CMINI
U - SEWER TIE IN 08/08/2013 APPROVED KKING
INSULATION 06/11/2013 APPROVED RMARVEL
Note: PER manny
ALL ROUGH 06/07/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ALL ROUGH 05/29/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 5/29/2013 3:17:42 PM BOND PANEL. 110.3. MISSING SCREW AT MASTER BEDROOM WINDOW. REVISE PLANS TO MATCH EXISTING WORK. ADD RECEPTACLE AT KITCHEN WALL WHERE 2FT OR MORE OF WALL SPACE. 210.52
LATH/BRICK/ WATER BARRIER 05/21/2013 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/09/2013 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/23/2013 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 4/23/2013 2:52:52 PM MISSING STRAPS ON THE CONNECTOR SCHEDULE..CIRCLED..MISSING BOLTS AT SILL PLATE REAR LEFT OF HOUSE CIRCLED..FILL HOLLOW CELL AT 10`` HIEGHT INSIDE OF HOUSE OF LINTEL FBC 107.2.1
TIE BEAM / LINTEL 04/01/2013 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 03/22/2013 APPROVED FREODICA
MONOLITHIC SLAB 03/12/2013 APPROVED CMINI
PLUMBING 1ST ROUGH UNDERGROUND 03/08/2013 APPROVED RMARVEL

Review History

Department Status Date In Date Out
ZON COMPLETE 11/18/2013 11/18/2013
Note: Released By: FREODICA final survey
SW1 COMPLETE 11/18/2013 11/18/2013
Note: Released By: FREODICA final survey
ZON COMPLETE 07/30/2013 08/01/2013
URB COMPLETE 07/30/2013 08/01/2013
SW1 COMPLETE 06/25/2013 06/25/2013
ZON HOLD 06/25/2013 06/26/2013
Note: Provide a revise landscaping plan showing landscaping around a/c and wraping left corner.
ELEC COMPLETE 06/05/2013 06/06/2013
BLD COMPLETE 05/06/2013 05/06/2013
BLD COMPLETE 04/04/2013 04/05/2013
SW1 COMPLETE 03/22/2013 03/22/2013
Note: Released By: FREODICA foundation survey
ZON COMPLETE 03/22/2013 03/22/2013
Note: Released By: FREODICA foundation survey
ELEC COMPLETE 02/19/2013 02/19/2013
ELEC HOLD 02/12/2013 02/12/2013
Note: Revise receptacle locations to meet NEC 210.52
PLUM COMPLETE 02/12/2013 02/12/2013
UD1 COMPLETE 02/12/2013 02/12/2013
BLD COMPLETE 02/12/2013 02/12/2013
MECH COMPLETE 02/12/2013 02/12/2013
URB COMPLETE 02/12/2013 02/14/2013
ZON COMPLETE 02/12/2013 02/12/2013
BLD HOLD 01/31/2013 02/01/2013
Note: 1. Provide a garage/house seperation door that meets 2010 FBC R302.5. 2. Provide for hazardous location glazing per 2010 FBC R 308.4. 3. Provide the Florida product approval installation instructions for the roofing, exterior doors, windows, and the garage door. per 2010 FBC 107.2.1. 4. The garage door product approval does not meet the design pressure on the plans per 2010 FBC R 301.1.
ELEC HOLD 01/31/2013 01/31/2013
Note: Revise receptacle locations to meet NEC 210.52 provide pep tank control location AHJ
ENGIN1 COMPLETE 01/31/2013 02/05/2013
MECH HOLD 01/31/2013 02/01/2013
Note: EPL Display Card on energy calculations shall be signed by builder per 2010 FBC EC 405.4.3.
PLUM HOLD 01/31/2013 01/31/2013
Note: Provide pipe size of branch line where kitchen sink and bathroom line are tied together per 2010 FBC 107.2.1
SW1 COMPLETE 01/31/2013 01/31/2013
UD1 HOLD 01/31/2013 02/01/2013
Note: must have an electrical plan showing the pep panel 3' from front corner on the same side as the pep tank as per the city utility standards
URB HOLD 01/31/2013 02/01/2013
Note: 1: Need to replace 2 of the crape myrtle understory trees with 2 shade type trees 2" @ 6" with a planted height of 8'. 2: Need to indicate the type of sod being used and if using st augustine or zoysia type a permanent irrigation system must be installed with 100% coverage.
ZON HOLD 01/31/2013 02/04/2013
Note: 1. Revise site plan to remove paver pation from easement and setback. 2. Revise site plan to remove walkway from easement. 3. Revise landscape plan to show lanscaping around a/c pad. 4. Revise color sheet to show trim meets the Light Reflective Value (LRV) of 30 or greater for earthtones.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 01/08/2014
REVISION ¤40.00 01/08/2014
REVISION ¤40.00 01/08/2014
REINSPECTION FEE ¤40.00 01/08/2014
REINSPECTION FEE ¤40.00 01/08/2014
NEW RESIDENTIAL INSPECTIONS ¤624.00 02/21/2013
SITE PLAN 20 ¤20.00 02/21/2013
SURCHARGE FS 533.721 ¤22.66 02/21/2013
SURCHARGE - FS 468.631 ¤22.66 02/21/2013
STORM WATER PERMIT FEES ¤80.00 02/21/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 02/21/2013
ADMIN FEE ¤20.00 02/21/2013
ELECTRIC FEE ¤247.20 02/21/2013
3% FIRE IMPACT FEE CREDIT (¤6.14) 02/21/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤204.51 02/21/2013
IMPACT FEE PARKS ¤1,321.51 02/21/2013
IMPACT FEE SCHOOL ¤3,600.00 02/21/2013
RECORDING FEE REIMBURSE DOC ¤52.50 02/21/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 02/21/2013
MECHANICAL FEE ¤247.20 02/21/2013
3% PARKS IMPACT FEE CREDIT (¤39.65) 02/21/2013
PLAN CHECK FEE ¤124.80 02/21/2013
PLUMBING FEE ¤247.20 02/21/2013
Fees Total Due: ¤0.00 Total Paid: ¤9,914.99