I want to search for...
Permit #2013020286
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7024-00530-0150 |
| Block: 00530 |
| Subdivision: 2167 - SECTION 24-PINE GROVE |
| Job Phone: (904)824-1468 |
| Location Address: 2 PROSPECT LN |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 04/04/2013 |
| NOC: RECORDED |
| Applicant name: JOHN E BUENING |
| Owner: WOJCIECHOWSKI PAUL TRUSTEE |
|
Address PO BOX 3251 FREERIKSTED, VI 00841 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤148,434.00 |
| Job Description: FIRE DAMAGE-TRUSSES, ROOFING, HVAC SYSTEM, PLUMBING, PATIO COVER, ETC. |
| Type: CN |
Contractor
PAUL DAVIS RESTORATION OF ST. AUGUSTINE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2050 DOBBS ROAD ST. AUGUSTINE, FL 32086 |
CGC056634 (Exp: 08/31/2026) | (904)824-1468 | (904)823-9586 |
Sub Contractors
CASEY CARCABA
| Status | Location Address | State License Number | Phone |
| INACTIVE |
58 S. DIXIE HIGHWAY ST AUGUSTINE, FL 32084 |
ER13014390 (Exp: 08/31/2024) | 904-814-6438 |
WADE H TAYLOR
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 1450 St. Augustine, FL 32085 |
CAC057890 (Exp: 08/31/2018) | 904-829-3358 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOHN EUGENE BUENING
| Status | Location Address | State License Number | Phone |
| CANCEL |
2139 Dobbs Road Unit 1 St. Augustine, FL 32086 |
CCC056947 (Exp: 08/31/2024) | (386) 824-1468 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/01/2013 | FINAL APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 10/30/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Requested at 10/29/2013 4:27:35 PM LOCK BOX CODE IS 1478, ALARM CODE IS 2013 Inspection Resulted at 10/30/2013 3:07:03 PM PROVIDE HOUSE ADDRESS/PROVIDE LOCKING CAPS AT GAS PORTS CONDENSING UNIT/NEED OUTLET COVER IN BEDROOM/IDENTIFY GFI OUTLETS IN KITCHEN BATHS AND GARAGE/PROPER BREAKER SIZE FOR CONDENSING UNIT/LABEL AHU FOR MOCP | |||
| ELECTRIC - EARLY POWER | 09/19/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Requested at 9/18/2013 2:10:56 PM PLANS INSIDE KITCHEN CABINETS NEXT TO RANGE. | |||
| ELECTRIC - EARLY POWER | 09/18/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 9/18/2013 1:42:22 PM PLANS AND PERMIT NEED TO BE ON SITE FOR INSPECTION. | |||
| INSULATION | 07/24/2013 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 07/23/2013 | CANCELLED BY APPLICANT | JMONTARULI |
| Note: THIS IS A REINSPECTION Contractor called to cancel this inspection | |||
| INSULATION | 07/22/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/22/2013 3:26:59 PM FIRE CAULK/FOAM/BLOCK NEED IN MULTIPLE SPOTS. USE FIRE RATED FOAM.FIREBLOCKING NEEDED…..F.B.C. 302.11 | |||
| INSULATION | 07/18/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/18/2013 2:51:15 PM MISSING FIRE CAULK/FOAM/BLOCKING IN MULTIPLE LOCATIONS. FIREBLOCKING NEEDED…..F.B.C. 302.11 | |||
| INSULATION | 07/17/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 7/17/2013 3:17:56 PM FIREWALL NEEDS TO BE FIRERESISTANT TIGHT FROM SLAB TO UNDERSIDE OF SHEATHING..FBC..302.3..NEED TO HAVE R30 PER ENERGY CALCS FOR ADJACENT TO ATTIC..FIREFOAM ANNULAR SPACE IN TOP PLATE WHERE WIRES ARE GOING THRU.. | |||
| ALL ROUGH | 07/17/2013 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/17/2013 3:17:55 PM FIREPLACE DUCT NOT EXTENDED OUTDOORS | |||
| ALL ROUGH | 07/01/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Requested at 6/28/2013 11:04:50 AM LOCK BOX CODE IS 1478, UNIT IS NOT OCCUPIED Inspection Resulted at 7/1/2013 3:30:29 PM MECHANICAL DUCT LAY OUT DOES NOT MATCH ORIGINAL APPROVED PLANS,DID NOT SEE ANY REVISIONS | |||
| ALL ROUGH | 06/24/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Requested at 6/21/2013 12:50:31 PM LOCK BOX CODE IS 1478, UNIT IS NOT OCCUPIED Inspection Resulted at 6/24/2013 3:09:16 PM MECHANICAL DUCT LAY OUT DOES NOT MATCH APPROVED PLANS. BATHROOM EXHAUST VENTS NEED TO BE HOOKED UP AT THIS INSPECTION. | |||
| ALL ROUGH | 06/14/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Requested at 6/13/2013 1:17:00 PM LOCK BOX CODE IS 1478, UNIT IS NOT OCCUPIED Inspection Resulted at 6/14/2013 2:48:21 PM PROVDECITY STAMPED APPROVED MECHANICAL DUCT LAYOUT. REMOVE THE "COURTESY LOOPS". NEC 2008 334. 24. WALL SPACE...210.52A1. ADDED RECEPTACLES NEED A REVISION. PROVIDE REVISED LOAD CALCS FOR ADDED DISPOSAL AND POSSIBLE MICROWAVE IF BEING INSTALLED. IT DOES NOT SHOW ON PLANS BUT WIRING WITH BOX IS #12AWG.NEC 2008 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/08/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/01/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/1/2013 3:15:28 PM PLANS NEED TO BE CITY STAMPED AND APPROVED. STILL NEED A TOTAL OF 3STUDS UNDER GIRDER TRUSSES. TIGHTEN ALL THREAD TIE DOWNS. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/25/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 4/25/2013 2:30:48 PM REMOVE SHINERS AND NAIL TO FBC 2010. DRIP EDGE NEEDS TO BE INSTALLED AT THIS INSPECTION. MISSING ENGINEERING ON TRUSS B-7. PER PLANS. MISSING 3 STUDS UNDER EACH GIRDER TRUSS PER APPROVED PLANS. NEED DETAIL SHOWING EXISTING ALL THREAD TIE DOWNS. FBC 2010 107.2.1. ALL THREAD TIE DOWNS NEED TO BE PROPERLY TIGHTENED. MULTIPLE LOOSE ALL THREAD TIE DOWNS THROUGH OUT HOUSE. |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 09/10/2013 | 09/13/2013 |
| ZON | HOLD | 09/03/2013 | 09/06/2013 |
| Note: Revise site plan to show the area of purposed work in clude the dimensions and setbacks. | |||
| BLD | COMPLETE | 08/27/2013 | 08/28/2013 |
| SW1 | COMPLETE | 08/27/2013 | 08/28/2013 |
| ZON | HOLD | 08/27/2013 | 08/30/2013 |
| Note: Provide a site plan for zoning approval. | |||
| MECH | COMPLETE | 07/11/2013 | 07/11/2013 |
| ELEC | COMPLETE | 06/20/2013 | 06/21/2013 |
| BLD | COMPLETE | 05/06/2013 | 05/06/2013 |
| BLD | COMPLETE | 03/26/2013 | 03/26/2013 |
| ZON | COMPLETE | 03/26/2013 | 03/27/2013 |
| BLD | HOLD | 03/25/2013 | 03/25/2013 |
| Note: 1. The previous comment has not been addressed. The provided plans cannot be designed by a party that is not the contractor, an architect or engineer. The plans submitted have notes the the engineer shall verify the details on these plans. The plans do not have any calculations or span tables. The plans do not have the contractors name and license number on them or a design professionals seal taking responsibility for the design. The screen enclosure must comply with all the previously noted comments from the last two submittals or the screen plans must be signed and sealed by a design professional. 2010 FBC 107.1. | |||
| ELEC | COMPLETE | 03/25/2013 | 03/26/2013 |
| MECH | COMPLETE | 03/25/2013 | 03/26/2013 |
| BLD | HOLD | 03/20/2013 | 03/20/2013 |
| Note: 1. The provided plans for the screen enclosure cannot be designed by a party that is not the contractor, an architect or engineer. 2. The plans have notes that the engineer shall verify the details on these plans. 3. The plans do not have any calculations or span tables. 4. The plans do not have the contractors name and license number on them for taking responsibility for the design. 5. The screen enclosure must comply with the all of the previously noted comments from the last submittal or the screen plans must be signed and sealed by a design professional. 2010 FBC 107.1. | |||
| ELEC | HOLD | 03/20/2013 | 03/21/2013 |
| Note: 1. Indicate either a switched light fixture or a switch controled receptacle outlet in the living room. NEC 210.70 (1) 2. Provide spacing and locations of receptacle outlets as required. Including but not limited to: exterior wall space in middle bedroom, wall space to left of door in master bedroom, to the left of the fireplace and the end or face of the peninsular counter. NEC 210.50 et al. 3. Provide GFCI protection for receptacle outlets in garage. NEC 210.8 4. Indicate AFCI Protection for receptacle outlets as required. NEC 210.12(B) 5. Electrical plans shall show the name and license number of the electrical contractor responsible for the design and installation of the electrical system(s) or it shall be signed and sealed by a Florida Licensed Engineer. FS 471 | |||
| MECH | COMPLETE | 03/20/2013 | 03/20/2013 |
| BLD | HOLD | 03/04/2013 | 03/04/2013 |
| Note: 1. The contractor designed composite roof screen enclosure plans must include the following. 1. the governing codes. 2.project name, location and the contractors name and license number 3. the connection details. 4.the material specifications for all structural components including the framing members (thickness and type), fasteners (type size and location) and screen densities. 5. The location magnitude and direction of controlling member forces and reactions and the controlling design load combinations at which they occur. | |||
| ELEC | HOLD | 03/04/2013 | 03/04/2013 |
| Note: 1. Provide GFCI receptacle at the front of the home. NEC 210.52(E)(1) 2. Provide GFCI service receptacle at condensing unit. NEC 210.63 3. Plans cannot be drawn in pencil. FBC 107.2.1 | |||
| PLUM | COMPLETE | 03/04/2013 | 03/05/2013 |
| MECH | HOLD | 03/04/2013 | 03/05/2013 |
| Note: 1. Hvac plan shall be separated from building plan per 2010 FBC 107.2.1. 2. Return air from bathroom is prohibited per 2010 FBC Residential M1602.2(4). 3. Provide duct sizes per 2010 FBC 107.2.1. 4. EPL Display Card on energy calculations shall be signed by the builder per 2010 FBC EC 405.4.3(1). | |||
| ZON | COMPLETE | 03/04/2013 | 03/05/2013 |
| BLD | HOLD | 02/14/2013 | 02/14/2013 |
| Note: 1. Provide Florida product approval and installation instructions for the exterior doors, overhead door and any windows that are going to be replaced. 2010 FBC 107.2.1. 2. Provide screen enclosure drawings. 2010 FBC 107.2.1. | |||
| ELEC | HOLD | 02/14/2013 | 02/14/2013 |
| Note: 1. Provide electrical drawings that include the layout, load calculations. 2010 FBC 107.2.1 2. Provide a service riser detail with conductor sizes. 2010 FBC 107.2.1. | |||
| MECH | HOLD | 02/14/2013 | 02/14/2013 |
| Note: 1. Provide hvac plan showing the existing damage and the proposed work to be done signed and sealed by FL registered Design Professional or by a FL licensed hvac contractor per 2010 FBC 107.2.1/107.3.4.3. If designed by contractor, signature and license number shall be indicated on plan. 2. Provide energy calculations/equipment sizing calculations per 2010 FBC EC 403.6.1. | |||
| PLUM | HOLD | 02/14/2013 | 02/14/2013 |
| Note: 1. Provide plan showing the existing damage and the proposed work to be done signed and sealed by FL registered Design Professional or by a FL licensed plumbing contractor per 2010 FBC 107.3.4.3. | |||
| ZON | HOLD | 02/14/2013 | 02/15/2013 |
| Note: Provide a site plan to show the patio and screen enclosure dimensions. Per Chapter 13: Section 13.02.06.E. “When repairs are being made to a building’s exterior walls surface, the wall may be repainted in the same color or another City approved color”. Please provide color material sheet. Per Chapter 13: Section 13.02.07 “Exterior wall finish materials shall include stucco, stone, natural brick, finished concrete, split-faced block, wood, or other materials including, but not limited to, synthetic materials similar in appearance and durability to those previously named. Provide exterior wall finishes. Provide a note on the elevation plans that the house will match the color and architectural elements of the existing house. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 10/31/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REINSPECTION FEE | ¤40.00 | 10/29/2013 |
| REVISION | ¤40.00 | 10/29/2013 |
| REVISION | ¤40.00 | 10/29/2013 |
| REVISION | ¤40.00 | 10/29/2013 |
| REVISION | ¤40.00 | 10/29/2013 |
| SITE PLAN 20 | ¤20.00 | 04/04/2013 |
| SURCHARGE FS 533.721 | ¤8.79 | 04/04/2013 |
| SURCHARGE - FS 468.631 | ¤8.79 | 04/04/2013 |
| ADMIN FEE | ¤20.00 | 04/04/2013 |
| ELECTRIC FEE | ¤149.06 | 04/04/2013 |
| MECHANICAL FEE | ¤149.06 | 04/04/2013 |
| PLAN CHECK FEE | ¤59.37 | 04/04/2013 |
| PLUMBING FEE | ¤149.06 | 04/04/2013 |
| REMODEL/ADDITION/ACCES INSPECT | ¤59.37 | 04/04/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,183.50 |