Permit #2013020286

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7024-00530-0150
Block: 00530
Subdivision: 2167 - SECTION 24-PINE GROVE
Job Phone: (904)824-1468
Location Address: 2 PROSPECT LN
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 04/04/2013
NOC: RECORDED
Applicant name: JOHN E BUENING
Owner: WOJCIECHOWSKI PAUL TRUSTEE

Address

PO BOX 3251

FREERIKSTED, VI 00841

Lot: 0150
Contracted Stated Job Value: ¤148,434.00
Job Description: FIRE DAMAGE-TRUSSES, ROOFING, HVAC SYSTEM, PLUMBING, PATIO COVER, ETC.
Type: CN

Contractor

PAUL DAVIS RESTORATION OF ST. AUGUSTINE
Status Location Address State License Number Phone Fax
ACTIVE

2050 DOBBS ROAD

ST. AUGUSTINE, FL 32086

CGC056634 (Exp: 08/31/2026) (904)824-1468 (904)823-9586

Sub Contractors

CASEY CARCABA
Status Location Address State License Number Phone
INACTIVE

58 S. DIXIE HIGHWAY

ST AUGUSTINE, FL 32084

ER13014390 (Exp: 08/31/2024) 904-814-6438
WADE H TAYLOR
Status Location Address State License Number Phone
CANCEL

P. O. Box 1450

St. Augustine, FL 32085

CAC057890 (Exp: 08/31/2018) 904-829-3358
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOHN EUGENE BUENING
Status Location Address State License Number Phone
CANCEL

2139 Dobbs Road Unit 1

St. Augustine, FL 32086

CCC056947 (Exp: 08/31/2024) (386) 824-1468

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/01/2013 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 10/30/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Requested at 10/29/2013 4:27:35 PM LOCK BOX CODE IS 1478, ALARM CODE IS 2013 Inspection Resulted at 10/30/2013 3:07:03 PM PROVIDE HOUSE ADDRESS/PROVIDE LOCKING CAPS AT GAS PORTS CONDENSING UNIT/NEED OUTLET COVER IN BEDROOM/IDENTIFY GFI OUTLETS IN KITCHEN BATHS AND GARAGE/PROPER BREAKER SIZE FOR CONDENSING UNIT/LABEL AHU FOR MOCP
ELECTRIC - EARLY POWER 09/19/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Requested at 9/18/2013 2:10:56 PM PLANS INSIDE KITCHEN CABINETS NEXT TO RANGE.
ELECTRIC - EARLY POWER 09/18/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 9/18/2013 1:42:22 PM PLANS AND PERMIT NEED TO BE ON SITE FOR INSPECTION.
INSULATION 07/24/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
INSULATION 07/23/2013 CANCELLED BY APPLICANT JMONTARULI
Note: THIS IS A REINSPECTION Contractor called to cancel this inspection
INSULATION 07/22/2013 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 7/22/2013 3:26:59 PM FIRE CAULK/FOAM/BLOCK NEED IN MULTIPLE SPOTS. USE FIRE RATED FOAM.FIREBLOCKING NEEDED…..F.B.C. 302.11
INSULATION 07/18/2013 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 7/18/2013 2:51:15 PM MISSING FIRE CAULK/FOAM/BLOCKING IN MULTIPLE LOCATIONS. FIREBLOCKING NEEDED…..F.B.C. 302.11
INSULATION 07/17/2013 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 7/17/2013 3:17:56 PM FIREWALL NEEDS TO BE FIRERESISTANT TIGHT FROM SLAB TO UNDERSIDE OF SHEATHING..FBC..302.3..NEED TO HAVE R30 PER ENERGY CALCS FOR ADJACENT TO ATTIC..FIREFOAM ANNULAR SPACE IN TOP PLATE WHERE WIRES ARE GOING THRU..
ALL ROUGH 07/17/2013 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 7/17/2013 3:17:55 PM FIREPLACE DUCT NOT EXTENDED OUTDOORS
ALL ROUGH 07/01/2013 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Requested at 6/28/2013 11:04:50 AM LOCK BOX CODE IS 1478, UNIT IS NOT OCCUPIED Inspection Resulted at 7/1/2013 3:30:29 PM MECHANICAL DUCT LAY OUT DOES NOT MATCH ORIGINAL APPROVED PLANS,DID NOT SEE ANY REVISIONS
ALL ROUGH 06/24/2013 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Requested at 6/21/2013 12:50:31 PM LOCK BOX CODE IS 1478, UNIT IS NOT OCCUPIED Inspection Resulted at 6/24/2013 3:09:16 PM MECHANICAL DUCT LAY OUT DOES NOT MATCH APPROVED PLANS. BATHROOM EXHAUST VENTS NEED TO BE HOOKED UP AT THIS INSPECTION.
ALL ROUGH 06/14/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Requested at 6/13/2013 1:17:00 PM LOCK BOX CODE IS 1478, UNIT IS NOT OCCUPIED Inspection Resulted at 6/14/2013 2:48:21 PM PROVDECITY STAMPED APPROVED MECHANICAL DUCT LAYOUT. REMOVE THE "COURTESY LOOPS". NEC 2008 334. 24. WALL SPACE...210.52A1. ADDED RECEPTACLES NEED A REVISION. PROVIDE REVISED LOAD CALCS FOR ADDED DISPOSAL AND POSSIBLE MICROWAVE IF BEING INSTALLED. IT DOES NOT SHOW ON PLANS BUT WIRING WITH BOX IS #12AWG.NEC 2008
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/08/2013 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/01/2013 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 5/1/2013 3:15:28 PM PLANS NEED TO BE CITY STAMPED AND APPROVED. STILL NEED A TOTAL OF 3STUDS UNDER GIRDER TRUSSES. TIGHTEN ALL THREAD TIE DOWNS.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/25/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 4/25/2013 2:30:48 PM REMOVE SHINERS AND NAIL TO FBC 2010. DRIP EDGE NEEDS TO BE INSTALLED AT THIS INSPECTION. MISSING ENGINEERING ON TRUSS B-7. PER PLANS. MISSING 3 STUDS UNDER EACH GIRDER TRUSS PER APPROVED PLANS. NEED DETAIL SHOWING EXISTING ALL THREAD TIE DOWNS. FBC 2010 107.2.1. ALL THREAD TIE DOWNS NEED TO BE PROPERLY TIGHTENED. MULTIPLE LOOSE ALL THREAD TIE DOWNS THROUGH OUT HOUSE.

Review History

Department Status Date In Date Out
ZON COMPLETE 09/10/2013 09/13/2013
ZON HOLD 09/03/2013 09/06/2013
Note: Revise site plan to show the area of purposed work in clude the dimensions and setbacks.
BLD COMPLETE 08/27/2013 08/28/2013
SW1 COMPLETE 08/27/2013 08/28/2013
ZON HOLD 08/27/2013 08/30/2013
Note: Provide a site plan for zoning approval.
MECH COMPLETE 07/11/2013 07/11/2013
ELEC COMPLETE 06/20/2013 06/21/2013
BLD COMPLETE 05/06/2013 05/06/2013
BLD COMPLETE 03/26/2013 03/26/2013
ZON COMPLETE 03/26/2013 03/27/2013
BLD HOLD 03/25/2013 03/25/2013
Note: 1. The previous comment has not been addressed. The provided plans cannot be designed by a party that is not the contractor, an architect or engineer. The plans submitted have notes the the engineer shall verify the details on these plans. The plans do not have any calculations or span tables. The plans do not have the contractors name and license number on them or a design professionals seal taking responsibility for the design. The screen enclosure must comply with all the previously noted comments from the last two submittals or the screen plans must be signed and sealed by a design professional. 2010 FBC 107.1.
ELEC COMPLETE 03/25/2013 03/26/2013
MECH COMPLETE 03/25/2013 03/26/2013
BLD HOLD 03/20/2013 03/20/2013
Note: 1. The provided plans for the screen enclosure cannot be designed by a party that is not the contractor, an architect or engineer. 2. The plans have notes that the engineer shall verify the details on these plans. 3. The plans do not have any calculations or span tables. 4. The plans do not have the contractors name and license number on them for taking responsibility for the design. 5. The screen enclosure must comply with the all of the previously noted comments from the last submittal or the screen plans must be signed and sealed by a design professional. 2010 FBC 107.1.
ELEC HOLD 03/20/2013 03/21/2013
Note: 1. Indicate either a switched light fixture or a switch controled receptacle outlet in the living room. NEC 210.70 (1) 2. Provide spacing and locations of receptacle outlets as required. Including but not limited to: exterior wall space in middle bedroom, wall space to left of door in master bedroom, to the left of the fireplace and the end or face of the peninsular counter. NEC 210.50 et al. 3. Provide GFCI protection for receptacle outlets in garage. NEC 210.8 4. Indicate AFCI Protection for receptacle outlets as required. NEC 210.12(B) 5. Electrical plans shall show the name and license number of the electrical contractor responsible for the design and installation of the electrical system(s) or it shall be signed and sealed by a Florida Licensed Engineer. FS 471
MECH COMPLETE 03/20/2013 03/20/2013
BLD HOLD 03/04/2013 03/04/2013
Note: 1. The contractor designed composite roof screen enclosure plans must include the following. 1. the governing codes. 2.project name, location and the contractors name and license number 3. the connection details. 4.the material specifications for all structural components including the framing members (thickness and type), fasteners (type size and location) and screen densities. 5. The location magnitude and direction of controlling member forces and reactions and the controlling design load combinations at which they occur.
ELEC HOLD 03/04/2013 03/04/2013
Note: 1. Provide GFCI receptacle at the front of the home. NEC 210.52(E)(1) 2. Provide GFCI service receptacle at condensing unit. NEC 210.63 3. Plans cannot be drawn in pencil. FBC 107.2.1
PLUM COMPLETE 03/04/2013 03/05/2013
MECH HOLD 03/04/2013 03/05/2013
Note: 1. Hvac plan shall be separated from building plan per 2010 FBC 107.2.1. 2. Return air from bathroom is prohibited per 2010 FBC Residential M1602.2(4). 3. Provide duct sizes per 2010 FBC 107.2.1. 4. EPL Display Card on energy calculations shall be signed by the builder per 2010 FBC EC 405.4.3(1).
ZON COMPLETE 03/04/2013 03/05/2013
BLD HOLD 02/14/2013 02/14/2013
Note: 1. Provide Florida product approval and installation instructions for the exterior doors, overhead door and any windows that are going to be replaced. 2010 FBC 107.2.1. 2. Provide screen enclosure drawings. 2010 FBC 107.2.1.
ELEC HOLD 02/14/2013 02/14/2013
Note: 1. Provide electrical drawings that include the layout, load calculations. 2010 FBC 107.2.1 2. Provide a service riser detail with conductor sizes. 2010 FBC 107.2.1.
MECH HOLD 02/14/2013 02/14/2013
Note: 1. Provide hvac plan showing the existing damage and the proposed work to be done signed and sealed by FL registered Design Professional or by a FL licensed hvac contractor per 2010 FBC 107.2.1/107.3.4.3. If designed by contractor, signature and license number shall be indicated on plan. 2. Provide energy calculations/equipment sizing calculations per 2010 FBC EC 403.6.1.
PLUM HOLD 02/14/2013 02/14/2013
Note: 1. Provide plan showing the existing damage and the proposed work to be done signed and sealed by FL registered Design Professional or by a FL licensed plumbing contractor per 2010 FBC 107.3.4.3.
ZON HOLD 02/14/2013 02/15/2013
Note: Provide a site plan to show the patio and screen enclosure dimensions. Per Chapter 13: Section 13.02.06.E. “When repairs are being made to a building’s exterior walls surface, the wall may be repainted in the same color or another City approved color”. Please provide color material sheet. Per Chapter 13: Section 13.02.07 “Exterior wall finish materials shall include stucco, stone, natural brick, finished concrete, split-faced block, wood, or other materials including, but not limited to, synthetic materials similar in appearance and durability to those previously named. Provide exterior wall finishes. Provide a note on the elevation plans that the house will match the color and architectural elements of the existing house.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/31/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REINSPECTION FEE ¤40.00 10/29/2013
REVISION ¤40.00 10/29/2013
REVISION ¤40.00 10/29/2013
REVISION ¤40.00 10/29/2013
REVISION ¤40.00 10/29/2013
SITE PLAN 20 ¤20.00 04/04/2013
SURCHARGE FS 533.721 ¤8.79 04/04/2013
SURCHARGE - FS 468.631 ¤8.79 04/04/2013
ADMIN FEE ¤20.00 04/04/2013
ELECTRIC FEE ¤149.06 04/04/2013
MECHANICAL FEE ¤149.06 04/04/2013
PLAN CHECK FEE ¤59.37 04/04/2013
PLUMBING FEE ¤149.06 04/04/2013
REMODEL/ADDITION/ACCES INSPECT ¤59.37 04/04/2013
Fees Total Due: ¤0.00 Total Paid: ¤1,183.50