Permit #2013020467

Permit Details

Status: COED

Parcel Id: 07-11-31-7025-000G0-0210
Total Square Footage: 940 sqft
Subdivision: -
Job Phone: 386-338-7785
Location Address: 85 CYPRESS POINT PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 05/29/2013
NOC: RECORDED
Applicant name: THOMAS M SCAGLIONE
Owner: INTERNATIONAL CARPET OF FLORIDA LLC

Address

101 OCEAN WAY N

PALM COAST , FL 32137

Contracted Stated Job Value: ¤25,000.00
Job Description: SUITE 9 INTERIOR BUILDOUT FOR RESTAURANT-- "FOCACCIA"
Type: CN

Contractor

T-CON GROUP, INC.
Status Location Address State License Number Phone
CANCEL

3246 NORTH POWERLINE ROAD

POMPANO BEACH, FL 33069

CBC1251999 (Exp: 08/31/2020) 954-825-8369

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone
CANCEL

17 UNIMAY CT

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2022) 386-931-2568
RICHARD LEE VONBROCKEN
Status Location Address State License Number Phone Fax
INACTIVE

1738 STATE AVE

HOLLY HILL, FL 32117

CAC035516 (Exp: 08/31/2026) (386)672-1950 (386)672-1952
IAN MICHEAL JOHNSON
Status Location Address State License Number Phone Fax
ACTIVE

4244 JACKSON STREET

PORT ORANGE, FL 32127

CCC1325915 (Exp: 08/31/2026) 386-760-0764 386-760-3080
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 09/10/2013 APPROVED CMINI
Note: PER OWNER
HVAC FINAL 09/10/2013 APPROVED CMINI
ELECTRIC FINAL 09/10/2013 APPROVED CMINI
MONOLITHIC SLAB 09/10/2013 APPROVED CMINI
ABOVE CEILING 09/10/2013 APPROVED CMINI
BUILDING FINAL 09/10/2013 APPROVED CMINI
FIRE FINAL 09/10/2013 FINAL APPROVED JHINDMAN
U-GREASE INTERCEPTOR FLOW/DYE TESTED 09/10/2013 APPROVED DSPENCER
U - UTILITY COMMERCIAL FINAL 09/10/2013 APPROVED DSPENCER
ELECTRIC - EARLY POWER 08/27/2013 APPROVED CMINI
Note: all safed off,called fpl to release power
FRAMING 07/03/2013 APPROVED CMINI
ELECTRIC 1ST ROUGH 07/03/2013 APPROVED CMINI
HVAC ROUGH 07/03/2013 APPROVED CMINI
PLUMBING 1ST ROUGH 07/03/2013 APPROVED CMINI
PLUMBING 2ND ROUGH 07/03/2013 APPROVED CMINI

Review History

Department Status Date In Date Out
ZON COMPLETE 05/24/2013 05/28/2013
FI1 COMPLETE 05/24/2013 05/29/2013
BLD COMPLETE 05/21/2013 05/21/2013
Note: Released By: JMCGOWEN
MECH COMPLETE 05/21/2013 05/21/2013
Note: Released By: FREODICA
MECH HOLD 05/15/2013 05/16/2013
Note: Previous hold comment below shall be addressed - 1. Support details for AHU and condensing unit shown on hvac plan signed by hvac contractor shall be deleted as design of these supports are beyond the scope of their license per 2010 FBC 107.2.1.
FI1 HOLD 05/15/2013 05/20/2013
Note: Held By: JMCGOWEN The new plans show a B vent but the manufacturers statement calls for their extra large hood. NFPA96
BLD HOLD 05/15/2013 05/15/2013
Note: Held By: JMCGOWEN
PLUM COMPLETE 05/15/2013 05/16/2013
ZON HOLD 05/15/2013 05/17/2013
Note: Revise plans adding screening for A/C unit. Elevations show unit is insufficiently screened from the public view on the east elevation.
ELEC COMPLETE 05/02/2013 05/02/2013
PLUM HOLD 05/02/2013 05/02/2013
Note: Previous comments shall be addressed - - Provide men’s and women’s restrooms that are ADA compliant per FPC chapter 4 and FBCA chapter 6. - Sanitary and domestic water riser diagrams are still incomplete. Coordinate with plans and resubmit corection per 2010 FBC 107.2.1.
FI1 HOLD 05/02/2013 05/02/2013
Note: 1. Provide pizza ovens manufacturers specifications that show the hood and venting. The new plans show a B vent but the manufacturers statement calls for their extra large hood. NFPA96
BLD HOLD 05/02/2013 05/02/2013
Note: 1. Provide a roof subcontractor for the roof work. 2010 FBC 107.2.1.
MECH HOLD 05/02/2013 05/02/2013
Note: 1. Support details for AHU and condensing unit shown on hvac plan signed by hvac contractor shall be deleted as design of these supports are beyond the scope of their license per 2010 FBC 107.2.1.
UD1 COMPLETE 05/02/2013 05/07/2013
Note: A CO hold is on place until additional utility fees and required forms are submitted
ZON HOLD 05/02/2013 05/03/2013
Note: Provide architectuals to show the roof top a/c units are being screen by building parapet.
ZON HOLD 04/10/2013 04/11/2013
Note: Need to modify development order to show a/c mounted on roof. Provide an elevations of all sides showing screening for proposed roof mounted a/c.
UD1 HOLD 04/09/2013 04/11/2013
Note: 1. Provide completed DBPR form 2. Additional capacity fees will be required. Fees were paid for retail/ office use for these units. Contact Utility Department for information on fees and DBPR form at 386-986-2355
FI1 HOLD 04/09/2013 04/10/2013
Note: 1. Provide the correct occupant load (kitchen areas are factored at 100 sq ft per person). 2010 FFPC ch 6. 2. On sheet A2 Provide the correct Life Safety Code NFPA number. (it is 101 not 102). 3. Provide the exhaust hood specifications that show the size of the exhaust duct and where it will exit the building. Provide any structural drawings needed to modify the building for the exhaust termination. NFPA 96.
BLD HOLD 04/09/2013 04/10/2013
Note: 1. Provide signed and sealed drawings for the air handler support. 2010 FBC 107.2.1. 2. Provide a roofing subcontractor for the roof modifications. 3. Provide details on the plans for how the exhaust hood duct is terminated to the outside. 2010 FBC 107.2.1.
MECH HOLD 04/09/2013 04/10/2013
Note: Previous comments items1and 3 shall be addressed - 1. Provide separate permit application for pizza hood oven per 2010 FBC 107.2.1/107.3.5. 3. Provide support details for AHU and duct per 2010 FBC 107.2.1. Note: On item 3, the submitted plan signed by licensed hvac contactor shows supporting details for ducts and AHU. Those details shall be signed and sealed by an engineer. Also, hvac consultant on the plan title block shall be deleted. An engineer or hvac contractor is allowed to design hvac duct system per 2010 FBC 107.1.
ELEC HOLD 04/09/2013 04/09/2013
Note: Provide signature and seal on copy righted drawing, provide legible symbols and legend on drawing FBC 107.2.1
PLUM HOLD 04/09/2013 04/10/2013
Note: Provide men’s and women’s restrooms that are ADA compliant per FPC chapter 4 and FBCA chapter 6, provide water incoming water size and division from cold water to water heater FBC 107.2.1
BLD HOLD 02/21/2013 02/25/2013
Note: 1. Provide the correct occupancy type per 2010 FBC 309. 2. Include the kitchen and service areas in the load calculation 2010 FFPC 101 7.3.1.2. 3. The rear hallway does not meet 2010 ADA for maneuvering clearances per Figure 404.2.4.1 (d). 4. The accessible toilet room door cannot obstruct the hallway more than 7 inches when fully open per 2010 FBC 1008.1.9.11. 5. Provide a detail for bracing the top of the walls to the structure 2010 FBC 107.2.1. 6. Provide complete pizza oven specifications including the ventilation requirements 2010 FBC 107.2.1. 7. Provide exhaust hood location with dimensions on the plans. 2010 FBC 107.2.1. 8. Additional comments may be required after these corrections have been made.
ELEC HOLD 02/21/2013 02/25/2013
Note: 1. Provide or indicate existing service receptale outlet(s) with-in 25 feet of HVAC condensing unit and Air Handling Unit. NEC 210.63 2. Provide lighting lay out and fixture specification(s). FBC 107.2.1 3. Provide revised load calculations for added service receptacles as needed. NEC 220.14(I)
FI1 HOLD 02/21/2013 02/25/2013
Note: 1. Provide the correct occupancy type per 2010 FFPC ch 6. 2. Include the kitchen and service areas in the load calculation. 2010 FFPC 101 7.3.1.2. Provide the correct NFPA code on plans. ( 101 not 102 ).
MECH HOLD 02/21/2013 02/25/2013
Note: 1. Provide separate permit application for pizza hood oven per 2010 FBC 107.2.1/107.3.5. 2. Provide location of condenser units on plan. If they are located on roof, the detail shown od plan shall be signed and sealed by engineer per 2010 FBC 107.2.1. 3. Provide support details for AHU and duct per 2010 FBC 107.2.1.
PLUM HOLD 02/21/2013 02/26/2013
Note: 1. The door at accessible unisex toilet shall comply with 2010 ADA for maneuvering clearances per Figure 404.2.4.1 (d). 2. The accessible toilet room door cannot obstruct the hallway more than 7 inches when fully open per 2010 FBC 1008.1.9.11. 5. 3. Sanitary riser diagram shows mop sink tied into a wet vented horizontal branch of bathroom group which is not allowed per 2010 FBC P 909.1. 4. For clarity, provide fixture/equipment names at domestic water riser diagram as most of them are missing per 2010 FBC 107.2.1. Also provide information on the source of hot water and show or indicate on plan. 5. Provide material specifications of DWV and domestic hot/cold water per 2010 FBC P 702/605
UD1 HOLD 02/21/2013 02/21/2013
Note: 1. Connect hand sinks in food prep area to grease line. 2. Provide completed DBPR form 3. Additional capacity fees will be required. Fees were paid for retail/ office use for these units. Contact Utility Department for information on fees and DBPR form at 386-986-2355
ZON COMPLETE 02/21/2013 02/22/2013

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN COMMERCIAL ¤60.00 05/29/2013
INSPECTION - COMMERCIAL ADD ¤175.00 05/29/2013
CONTRACTOR CHANGE ¤40.00 05/29/2013
CONTRACTOR CHANGE ¤80.00 05/29/2013
ELECTRIC FEE ¤75.00 05/29/2013
FIRE PLANS REVIEW ¤25.00 05/29/2013
MECHANICAL FEE ¤75.00 05/29/2013
PLAN CHECK FEE ¤100.00 05/29/2013
PLUMBING FEE ¤75.00 05/29/2013
SITE PLAN 20 ¤20.00 05/29/2013
SURCHARGE FS 533.721 ¤8.40 05/29/2013
SURCHARGE - FS 468.631 ¤8.40 05/29/2013
Fees Total Due: ¤0.00 Total Paid: ¤741.80