Permit #2013020475
Permit Details
Status: COED
| Parcel Id: 07-11-31-7002-00010-0010 |
| Block: 00010 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: (386) 446-5850 |
| Location Address: 1 FARRADAY LN |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 05/13/2013 |
| NOC: RECORDED |
| Applicant name: CHARLES DALLAS RINEK |
| Owner: PALM COAST RENT LLC |
|
Address 160 CYPRESS POINT PKWY PALM COAST, FL 32164 |
|
Address SUITE B 202 PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤75,000.00 |
| Job Description: INTERIOR REMODEL / EXTERIOR REPAIRS-- VIRTUAL HOME REALTY |
| Type: CN |
Contractor
CHARLES RINEK CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 352502 Palm Coast, FL 32137 |
CGC046080 (Exp: 08/31/2026) | (386) 446-5850 | (386)445-9992 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
Inspection History
| Type | Request Date | Result | Inspector |
| LDSC- LANDSCAPE FINAL | 03/11/2014 | FINAL APPROVED | WBUTLER |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 03/05/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| HVAC FINAL | 03/05/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING FINAL | 02/28/2014 | APPROVED | JHINDMAN |
| HVAC FINAL | 02/28/2014 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 2/28/2014 3:26:48 PM 1. INSTALL DAMPER ACCESS DOOR IN AHU CLOSET. INSTALL ALL REGISTER GRILLS. 2010 FBC 110.5. | |||
| ELECTRIC FINAL | 02/28/2014 | APPROVED | JHINDMAN |
| LDSC- LANDSCAPE FINAL | 02/28/2014 | Disapproved -FEE REQUIRED | WBUTLER |
| Note: Punchlist for 1 Farraday Lane 2-28-14 Permit Number 2013020475 1. Need landscape and irrigation as-builts to be completed and signed and sealed by the landscape architect or irrigation professional (for irrigation plan). There were some changes noted on the irrigation: a) Irrigation controller not in the same location as the plan b) Irrigation valves not in the same location as the plan c) Flush plugs not found or in valve boxes d) Need dimensions from two fixed points for the location of valve boxes, flush plug boxes and wire splice boxes e) Rain sensor location not approved as it is under the eave and on the side of the building. Needs to be relocated so building or eave will not affect rain detection. Show as-built location for this rain sensor. f) Irrigation controller is not as specified on the plans. Change as-built to reflect this. g) Actual counts of new plants are not correct, so need to modify as-built to reflect correct number. 2. Irrigation controller is not plugged in as outlet does not appear to be finished. Also the required Solar Sync option was not installed on the controller to make it a smart controller. 3. Need a card in the controller that states what zone operates what area of the site and has suggested run times for each zone. There are three valves in the valve box, but what it the third valve for since the irrigation plan only shows two zones? 4. There is a big hole in the south landscape buffer that needs to be filled and mulched. Irrigation pipes seem to be affected as well, so check for breaks and fix if needed. | |||
| U - UTILITY COMMERCIAL FINAL | 02/28/2014 | APPROVED | DSPENCER |
| BUILDING FINAL | 02/28/2014 | APPROVED | JHINDMAN |
| FIREWALL FINAL | 02/28/2014 | APPROVED | JHINDMAN |
| FIRE FINAL | 02/28/2014 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 2/28/2014 3:26:47 PM 1. PROVIDE FIRE EXTINGUISHERS PER NFPA10. 2. SEAL DRYWALL IN AHU CLOSETS. J. HINDMAN 986-3784. | |||
| ELECTRIC - EARLY POWER | 02/20/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 2/20/2014 2:57:21 PM CALLED FPL TO RELEASE FINAL POWER,SPOKE WITH MARYANN.PALMETTO ELEC | |||
| FIREWALL NAILING | 12/17/2013 | APPROVED | RMARVEL |
| LATH/BRICK/WATER BARRIER | 11/05/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FIREWALL NAILING | 11/04/2013 | APPROVED | JHINDMAN |
| LATH/BRICK/WATER BARRIER | 10/28/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 10/28/2013 3:06:28 PM STAPLES NOT NAILED INTO STUDS PER FBC 703.6.3 AND ASTM STANDARD C1063 | |||
| INSULATION | 10/24/2013 | APPROVED | RMARVEL |
| FRAMING | 10/22/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH | 10/22/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 2ND ROUGH | 10/22/2013 | APPROVED | CMINI |
| HVAC ROUGH | 10/22/2013 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH | 10/09/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: requested by contractor Inspection Resulted at 10/9/2013 3:12:42 PM NEED TO HAVE PRESSURE GAUGE ON SANITARY AND WATER PIPPING ALSO ON SANITARY THAT WAS REMOVED AND PUT BACK IN PLACE TO INSTALL TRUSSES. FPC 312...NEED RVISION FOR ADD FLOOR DRAIN AND WATER PIPPING FOR FISH TANK..FBC 107.2 | |||
| ELECTRIC 2ND ROUGH | 10/09/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 10/9/2013 3:12:43 PM NEED REVISION FOR LOCATION AND DELETED OUTLETS AND SWITCHES..NEED TO REMOVE OLD WORK..MULTIPLE LOCATIONS..STRAP ABOVE PANELS..DISCONNECTS AT C.U. CHECK FOR CLEARANCE.. | |||
| HVAC ROUGH | 10/09/2013 | APPROVED | CMINI |
| FRAMING | 10/09/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 10/9/2013 3:12:43 PM NEED REVISION OR CORRECTION FOR TRUSSES NOT ANCHORED PER PLAN,FIREBLOCKING NEEDED..AREAS..FIREWALL NEEDS TO BE SEALED PER CODE..LOOKED AT WINDOWS AND DOORS INSTALLED.OK...LOOKED AT PARAPET WALL OK.. | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 07/03/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 06/24/2013 | APPROVED | DROCKWELL |
| Note: Inspection Resulted at 6/24/2013 12:24:29 PM FIIL LCELL OK....DR | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 06/21/2013 | PARTIALLY APPROVED | DROCKWELL |
| Note: Inspection Resulted at 6/21/2013 2:27:53 PM ENTRY COLUMN AREA WALL SHEATHING. | |||
| FOOTER | 06/11/2013 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/30/2013 | 11/01/2013 |
| BLD | COMPLETE | 10/16/2013 | 10/16/2013 |
| ELEC | COMPLETE | 10/16/2013 | 10/16/2013 |
| MECH | COMPLETE | 10/16/2013 | 10/16/2013 |
| Note: Revision - relocated Condenser unit No.7. | |||
| PLUM | COMPLETE | 10/16/2013 | 10/16/2013 |
| Note: Revision- added fish tanks including water supply and drain. | |||
| ELEC | COMPLETE | 10/03/2013 | 10/07/2013 |
| ELEC | HOLD | 09/30/2013 | 10/02/2013 |
| Note: Incorrect main panel amperage. panel layout states 125, load states larger. Contractor contacted 10/1/13 to bring in revised calculation sheets | |||
| BLD | COMPLETE | 09/19/2013 | 09/20/2013 |
| Note: Revision- replaced sliding glass door, closed exterior door opening and add interior door at breakroom. | |||
| BLD | COMPLETE | 08/30/2013 | 08/30/2013 |
| PLUM | COMPLETE | 05/10/2013 | 05/13/2013 |
| MECH | COMPLETE | 05/09/2013 | 05/09/2013 |
| PLUM | HOLD | 05/09/2013 | 05/09/2013 |
| Note: Submitted sanitary and domestic water riser diagrams show the plumbing system for the whole building. Clarify the scope work as plan shows only one(1) bathroom on the first floor would be renovated. Coordinate riser diagrams with plans and submit correction per 2010 FBC 107.2.1. | |||
| PLUM | HOLD | 05/02/2013 | 05/03/2013 |
| Note: 1. Provide sanitary and domestic water riser diagrams per 2010 FBC 107.3.5. 2. Provide dimensions of new H.C. toilet and ADA details per 2010 FBC Accessibility chaper 4 and 6. | |||
| PLLA | COMPLETE | 05/02/2013 | 05/03/2013 |
| ELEC | COMPLETE | 05/02/2013 | 05/03/2013 |
| BLD | COMPLETE | 05/02/2013 | 05/03/2013 |
| FI1 | COMPLETE | 05/02/2013 | 05/03/2013 |
| MECH | HOLD | 05/02/2013 | 05/03/2013 |
| Note: 1. Provide only one(1) hvac plan as there are two (2) plans submitted. Coordinate and compile all required information previously requested per 2010 FBC 107.2.1. Response to previous comments need clarification such as - 1c. Location of AHU adjacent to bath 1(existing H.C. toilet) does not match with First Floor Plan. 1f. Indicate which units are new or existing. Previous comment item 3 shall be addressed - 3. Provide exhaust duct layout for new H.C. toilet (bath 2) and exhaust fan specifications per 2010 FBC 107.3.5. | |||
| FI1 | HOLD | 04/04/2013 | 04/05/2013 |
| Note: 1. Provide occupant load with a lifesafety plan. 2010 FFPC | |||
| DSD | COMPLETE | 04/04/2013 | 04/04/2013 |
| ELEC | HOLD | 04/04/2013 | 04/05/2013 |
| Note: Provide receptacle locations NEC 210.52 provide load calculations NEC 220 provide panel location and schedule NEC 230 | |||
| PLLA | HOLD | 04/04/2013 | 04/04/2013 |
| Note: 1 Florida Park Drive 4/4/13 1. Need to show location of electric valves on irrigation plan. It appears that the lawn spray heads are connected to the drip irrigation, which is not allowed. 2. Need specifications for drip irrigation and installation typical. Flush plugs in valve boxes are required. 3. If a new irrigation controller is needed, need to make it a smart controller (example: a Hunter Pro-C with the Solar Sync option). 4. The Institutional Series spray has been replaced by Pro-Spray PRS30 spray bodies (specification is PROS-06-PRS30-CV-15H for a 6” high-pop with a 15’ radius 180 degree nozzle). Change the specs to reflect this. 5. Need pipe sizing or chart for sizing. 6. Need a zone gallonage chart depicting the nozzle GPM or drip demand. | |||
| MECH | HOLD | 04/04/2013 | 04/05/2013 |
| Note: 1. For clarification, provide the following information per 2010 FBC 107.2.1. a. Identification or designation of each air handling units (indoor units). b. Location and identification of each condesing units (outdoor units) that corresponds to each AHU's. c. Location of AHU adjacent to bath 1(existing H.C. toilet) does not match with First Floor Plan. d. Outdoor air duct layout for each AHU's. e. First floor plan shows 3 tenant spaces vs. 4 spaces on hvac plan. f. Indicate which units new or existing. 2. Provide outdoor air calculations per 2010 FBC M 403. 3. Provide exhaust duct layout for new H.C. toilet (bath 2) and exhaust fan specifications per 2010 FBC 107.3.5. | |||
| ZON | COMPLETE | 04/04/2013 | 04/04/2013 |
| BLD | HOLD | 04/04/2013 | 04/05/2013 |
| Note: 1. Provide occupant load with all egress details 2010 FBC Ch. 10. | |||
| DSD | HOLD | 02/25/2013 | 02/25/2013 |
| Note: Provide a color render showing the name and manufacture of the proposed colors of the exterior of new stucco finish. Include the trim, soffits, etc. | |||
| FI1 | HOLD | 02/25/2013 | 02/25/2013 |
| Note: 1. provide the proposed occupancy type or state if the building is going to be a shell. 2010 FFPC ch6. 2. Provide a ul design for the floor ceiling assembly. 2010 FFPC ch 8. | |||
| PLLA | HOLD | 02/25/2013 | 02/27/2013 |
| Note: 2/27/13 1. It has been noticed that some work has already been done at this site in the front of the building that affects the minimum landscape requirements that need to be addressed at this time. There was a wooden bridge over the retention area just west of the front entrance and if this bridge is not going to be replaced, a landscape and irrigation plan must be submitted that shows the required perimeter landscape plantings to fill in where there is no longer a bridge or previously existing plants. Requirements for the buffer along Florida Park Drive are the following: a. Continuous buffer planting of shrubs minimum height of 24” at time of planting in 3-gallon containers, spaced no farther than 3’ on center. b. One understory tree for every 50 lineal feet of building length along Florida Park Drive (there were some previously planted ligustrum trees that were pruned back to shrubs that either need to be replaced or allowed to grow taller. c. The existing irrigation system needs to be checked to make sure it will adequately cover all the new and existing plantings. If not, you need to submit a revised irrigation plan. d. A landscape and irrigation plan must be submitted signed and sealed by a registered landscape architect. e. There are other requirements, such a shade trees every 25 lineal feet and accent plants, but since this site is an existing non-conforming condition, if nothing else is being changed but the bridge removal, the City will not require the items in section e. | |||
| BLD | HOLD | 02/21/2013 | 02/25/2013 |
| Note: 1. provide proposed occupancy type or state if the building is to be a shell only. 2010 FBC ch3. 2. If it is going to be a shell remove Virtual Homes Realty and New Church from plans 2010 FBC 107.2.1 3. Remove single toilet space from plans 2010 FBC P 403.1. 4. Provide a truss layout with the required hangers and connections. 2010 FBC 107.2.1. 5. Provide a UL design for the floor ceiling assembly. 2010 FBC 712. 6. Provide a wall detail for the exterior walls at the new windows. 2010 FBC 107.2.1. 7. Change the swing of the foyer doors to swing out 2010 FBC 1008 .1.2. 8. Provide a foundation plan and structural reference marks for the new exterior wall details on the floorplans 2010 FBC 107.2.1. 9. coordinate drawings to show the new metal roofing. 2010 FBC 107.2.1. 10. Additional comments may be required after these comments have been addressed. | |||
| ELEC | HOLD | 02/21/2013 | 02/27/2013 |
| Note: 1. Provide electrical plans with sufficient detail for review, construction and inspection of this proposed project. Plans must clearly indicate what is existing, what is to remain and any new electrical work. | |||
| MECH | HOLD | 02/21/2013 | 02/22/2013 |
| Note: 1. Provide hvac plans and details suitable for review, construction and inspection either signed and sealed by Florida registered design professional or hvac contractor with name and license number per 2010 FBC 107.2.1. 2. Provide energy calculations per 2010 FBC 107.3.5. | |||
| PLUM | HOLD | 02/21/2013 | 02/22/2013 |
| Note: Provide plumbing plans and details suitable for review, construction and inspection either signed and sealed by Florida registered design professional or plumbing contractor with name and license number per 2010 FBC 107.2.1. | |||
| ZON | HOLD | 02/21/2013 | 02/22/2013 |
| Note: Provide a color render showing the name and manufactor of the proposed colors of the exterior of new stucco finish. include the trim, sofitts, etc. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/11/2014 |
| REINSPECTION FEE | ¤40.00 | 03/11/2014 |
| REINSPECTION FEE | ¤40.00 | 03/11/2014 |
| REINSPECTION FEE | ¤40.00 | 03/11/2014 |
| REINSPECTION FEE | ¤40.00 | 03/11/2014 |
| REINSPECTION FEE | ¤40.00 | 03/11/2014 |
| REINSPECTION FEE | ¤40.00 | 03/11/2014 |
| REVISION | ¤40.00 | 03/11/2014 |
| REVISION | ¤40.00 | 03/11/2014 |
| REVISION | ¤40.00 | 03/11/2014 |
| REVISION | ¤40.00 | 03/11/2014 |
| REVISION | ¤40.00 | 03/11/2014 |
| REVISION | ¤40.00 | 03/11/2014 |
| REVISION | ¤40.00 | 10/03/2013 |
| REVISION | ¤40.00 | 10/01/2013 |
| SITE PLAN 20 | ¤20.00 | 05/13/2013 |
| SURCHARGE FS 533.721 | ¤15.00 | 05/13/2013 |
| SURCHARGE - FS 468.631 | ¤15.00 | 05/13/2013 |
| ADMIN COMMERCIAL | ¤60.00 | 05/13/2013 |
| INSPECTION - COMMERCIAL ADD | ¤525.00 | 05/13/2013 |
| ELECTRIC FEE | ¤105.00 | 05/13/2013 |
| FIRE PLANS REVIEW | ¤25.00 | 05/13/2013 |
| MECHANICAL FEE | ¤105.00 | 05/13/2013 |
| PLAN CHECK FEE | ¤100.00 | 05/13/2013 |
| PLUMBING FEE | ¤105.00 | 05/13/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,675.00 |