I want to search for...
Permit #2013020583
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-00640-0140 |
| SCREEN PORCH (SOLID ROOF) : 867 sqft |
| Total Square Footage: 867 sqft |
| Block: 00640 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-445-9055 |
| Location Address: 33 ELLINGTON DR |
| Type: PO - POOL |
| Issue Date: 04/04/2013 |
| NOC: RECORDED |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: ANTUNES ARTUR & CIDELIA H&W |
|
Address 33 ELLINGTON DRIVE PALM COAST, FL 32164 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤31,000.00 |
| Job Description: SWIMMING POOL W SCREEN ENCLOSURE |
| Type: CN |
Contractor
NEW COASTAL HOMES INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
399 SW PALM COAST PKWY PALM COAST, FL 32137 |
UNIT #5 PALM COAST, FL 32137 |
CGC1519145 (Exp: 08/31/2018) | 386-445-9055 | 386-445-9056 |
Sub Contractors
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
ROY CHARLES WALDHAUER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , 0 |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
DAVID CASH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
45 SOUTH DIXIE HIGHWAY ST. AUGUSTINE, FL 32084 |
01613 (Exp: 08/31/2014) | (386)437-3433 | 904-829-1844 |
ROY C WALDHAUER
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET BUNNELL, FL 32110 |
#103 BUNNELL, FL 32110 |
CPC1457705 (Exp: 08/31/2026) | 386-446-5524 | 386-446-5107 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 01/28/2014 | FINAL APPROVED | DSPENCER |
| ROW DAMAGE | 01/23/2014 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| ROW DAMAGE | 01/22/2014 | Disapproved - NO FEE | GLALIMA |
| Note: CAN NOT PUT '' SALT CHLORINATION OR OTHER AS CHLORINE IN SWALE SYSTEM . AND YOUR 4" DRAINAGE NEEDS TO BE 15 ' BACK FROM EDGE OF ROAD. FAILED | |||
| POOL FINAL | 01/21/2014 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| POOL FINAL | 01/14/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 1/14/2014 2:53:54 PM PROVIDE FINAL SURVEY/SCREEN OR VENTED CAP AT DOWN TURNED PVC. | |||
| ELECTRIC AND ALARM | 12/09/2013 | APPROVED | DROCKWELL |
| FINAL SURVEY (OFFICE USE ONLY) | 07/18/2013 | APPROVED | JMCGOWEN |
| POOL DECK | 05/22/2013 | APPROVED | CMINI |
| Note: Added on per Joe | |||
| STEEL AND GROUND | 04/17/2013 | APPROVED | RMARVEL |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 07/18/2013 | 07/18/2013 |
| Note: Released By: JMCGOWEN final survey | |||
| SW1 | COMPLETE | 07/18/2013 | 07/18/2013 |
| Note: Released By: JMCGOWEN final survey | |||
| ZON | COMPLETE | 05/06/2013 | 05/08/2013 |
| BLD | COMPLETE | 04/03/2013 | 04/30/2013 |
| BLD | HOLD | 03/27/2013 | 04/01/2013 |
| Note: 1. Provide the correct exposure and design pressure on the plans. 2 identify the footing on the plans. 2010 FBC 107.2.1. | |||
| BLD | HOLD | 03/26/2013 | 03/26/2013 |
| Note: The following comments from 3/22/2013 have not been addressed. 1. The building design criteria for the screen enclosure is for exposure B and C. The design wind pressure does not meet the pressure for exposure B and C in table 2202.4 of the 2010 FBC. 2. Tables 3 and 6 on sheet 2 of the screen plans are for 130 MPH wind zones. The design criteria windspeed is 120 MPH on the page. Provide matching windspeeds on the documents. 2010 FBC 107.2.1. 3. The tables on page 2 do not meet the design pressures per Table 2202.4 of the 2010 FBC. 4. Identify the footing type that is going to be used 2010 FBC 107.2.1. 5 The heater loss on the TDH calculation form does not match the heater loss per GPM on the specification sheet. 2010 FBC 107.2.1. 6 The revised gas riser drawing cannot have two different names on it. It must have the contractors name and license number. 2010 FBC 107.1. | |||
| BLD | HOLD | 03/20/2013 | 03/22/2013 |
| Note: 1. The building design criteria for the screen enclosure is for exposure B and C. The design wind pressure does not meet the pressure for exposure B and C in Table 2202.4 of the 2010 FBC. 2. Tables 3 and 6 on sheet 2 of the screen plans are for 130 MPH wind zones. The Design Criteria windspeed is 120 MPH on the page. Provide matching windspeeds on the documents. 2010 FBC 107.2.1. 3. The tables on page 2 do not meet the design pressures per Table 2202.4 of the 2010 FBC. 4. Identify the footing type that is going to be used. 2010 FBC 107.2.1. 5. The heater loss on the TDH calculation form does not match the heater loss per GPM on the specification sheet. 2010 FBC 107.2.1. 6. The license number on the gas riser is not the gas riser designers number. 2010 FBC 107.1 | |||
| SW1 | COMPLETE | 03/20/2013 | 03/21/2013 |
| ZON | HOLD | 03/20/2013 | 05/02/2013 |
| Note: 1. Please provide a revised site plan showing the new enlarged pool deck with the setback dimensions from the rear and side lot lines. The site plan must be consistent with the revised screen enclosure plan. | |||
| BLD | HOLD | 02/26/2013 | 02/26/2013 |
| Note: 1. Identify the footing size and type on the plans 2010 FBC 107.1. 2. Provide tables for each component with the same windspeed and exposure. 2010 FBC 107.2.1.3. Identify the component sizes and spacing on the tables. 2010 FBC 107.2.1 4. The column spacing on the layout page does not work with the tables provided. 2010 FBC 107.2.1. 5. Provide the screen mesh size that is going to be used. Your tables have two different sizes and cannot be used together. 2010 FBC 107.2.1. 6.Provide roof span tables with an exposure category of C per the Design Criteria on the plans. 2010 FBC 107.2.1. 7. Provide APSP-15 pump calculations per 2010 FBC Energy 403.9. 8. Provide data sheet for filter loss. APSP-7. 9. Provide complete pool heater specifications. If the heater is gas, provide a gas subcontractor and a gas riser diagram. If it is electric provide a complete electrical load calculation for the existing house with the additional pool and heater loads. 2010 FBC 107.2.1. 10. Provide a pool subcontractor for the non structural work per 489.113 3 (c) Florida state statute. | |||
| SW1 | COMPLETE | 02/26/2013 | 02/26/2013 |
| ZON | COMPLETE | 02/26/2013 | 02/26/2013 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 01/27/2014 |
| REVISION | ¤40.00 | 01/27/2014 |
| SITE PLAN 20 | ¤20.00 | 04/04/2013 |
| SURCHARGE FS 533.721 | ¤3.30 | 04/04/2013 |
| SURCHARGE - FS 468.631 | ¤3.30 | 04/04/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/04/2013 |
| ADMIN FEE | ¤20.00 | 04/04/2013 |
| CONTRACTOR CHANGE | ¤40.00 | 04/04/2013 |
| PERMIT FEE | ¤160.00 | 04/04/2013 |
| PLAN CHECK FEE | ¤40.00 | 04/04/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤446.60 |