Permit #2013030001
Permit Details
Status: COED
| Parcel Id: 07-11-31-4920-00000-0030 |
| Total Square Footage: 1000 sqft |
| Block: 00000 |
| Subdivision: 1146 - OLD KINGS ROAD PROF. PARK |
| Job Phone: (386)445-9393 |
| Location Address: 29 OLD KINGS RD N |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 04/03/2013 |
| NOC: Unknown |
| Applicant name: ANTONIO AMARAL JR |
| Owner: AQUA INVESTMENT COMPANY OF PALM COAST |
|
Address 13 UTILITY DRIVE PALM COAST, FL 32164 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤2,400.00 |
| Job Description: INTERIOR RENOVATIONS "DR. DANTINI'S OFFICE" |
| Type: CN |
Contractor
AMARAL CUSTOM HOMES INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 Utility Drive PALM COAST, FL 32135 |
CBC058062 (Exp: 08/31/2020) | (386)445-9393 | (386)446-0403 |
Sub Contractors
RICHARD R EDWARDS
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 1637 Bunnell, FL 32110 |
ER0011603 (Exp: 08/31/2022) | (386) 437-1537 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE FINAL | 06/05/2013 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| U - UTILITY COMMERCIAL FINAL | 06/04/2013 | APPROVED | DSPENCER |
| PLUMBING FINAL | 06/04/2013 | APPROVED | CMINI |
| HVAC FINAL | 06/04/2013 | APPROVED | CMINI |
| ELECTRIC FINAL | 06/04/2013 | APPROVED | CMINI |
| BUILDING FINAL | 06/04/2013 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/4/2013 3:17:52 PM FIRE | |||
| FIRE FINAL | 06/04/2013 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 6/4/2013 3:33:08 PM 1. PROVIDE FIRE EXTINGUISHER WITH A CURRENT INSPECTION TAG. NFPA10 | |||
| FRAMING | 04/10/2013 | APPROVED | CMINI |
| ABOVE CEILING | 04/10/2013 | APPROVED | CMINI |
| ELECTRIC 2ND ROUGH | 04/10/2013 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 4/10/2013 3:30:55 PM NEED REVISION FOR ADDED ELECTRIC BY FINAL..PANEL SCHEDULE NEEDS TO MATCH BY FINAL | |||
| HVAC ROUGH | 04/10/2013 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 4/10/2013 3:30:53 PM NEED REVISION FOR CHANGE BY HVAC FINAL | |||
| PLUMBING 2ND ROUGH | 04/10/2013 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/23/2013 | 05/23/2013 |
| ELEC | COMPLETE | 05/23/2013 | 05/23/2013 |
| MECH | COMPLETE | 05/23/2013 | 05/23/2013 |
| BLD | COMPLETE | 03/27/2013 | 03/27/2013 |
| ELEC | COMPLETE | 03/27/2013 | 03/27/2013 |
| PLUM | COMPLETE | 03/27/2013 | 03/27/2013 |
| BLD | HOLD | 03/12/2013 | 03/12/2013 |
| Note: 1. The hallway at the front restroom must be 48 inches wide to comply with the maneuvering clearance requirement of 2010 FBC Accessibility 404.2.4.1 | |||
| FI1 | COMPLETE | 03/12/2013 | 03/12/2013 |
| MECH | COMPLETE | 03/12/2013 | 03/12/2013 |
| PLUM | HOLD | 03/12/2013 | 03/12/2013 |
| Note: Remove the plumbers name and license number from a signed and sealed plan SS371 | |||
| ELEC | HOLD | 03/12/2013 | 03/12/2013 |
| Note: 1. Provide load(s) and circuit numbering on relocated branch circuits. NEC 220.16 | |||
| BLD | HOLD | 03/01/2013 | 03/04/2013 |
| Note: 1. Provide hallways that comply with the maneuvering clearances per the 2010 FBC Accessibility code 404.2.4.1. | |||
| ELEC | HOLD | 03/01/2013 | 03/05/2013 |
| Note: 1. Provide load(s) and circuit numbering on relocated branch circuits. NEC 220.16 | |||
| FI1 | HOLD | 03/01/2013 | 03/04/2013 |
| Note: 1. Provide occupant load and square footage. 2010 FFPC 7.3.1. | |||
| MECH | HOLD | 03/01/2013 | 03/04/2013 |
| Note: Provide the following informations per 2010 FBC 107.2.1- a. Overall dimensions and occupant load of the proposed renovation. b. Identify the existing AHU(s) and their capacities to verify the distributed supply air in CFM(s). c. Provide return air at the reception unless the interior window is openable. d. Provide existing occupancy use and classification. If different to the proposed occupancy use, submit energy calculations. 2. Provide outdoor air requirement (ventilation) and duct layout per 2010 FBC M 403. | |||
| PLUM | HOLD | 03/01/2013 | 03/04/2013 |
| Note: 1. Provide plumbing plans and details suitable for review, construction and inspection per 2010 FBC 107.2.1. | |||
| UD1 | COMPLETE | 03/01/2013 | 03/04/2013 |
| ZON | COMPLETE | 03/01/2013 | 03/04/2013 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 06/06/2013 |
| REVISION | ¤40.00 | 06/06/2013 |
| SITE PLAN 20 | ¤20.00 | 04/03/2013 |
| SURCHARGE FS 533.721 | ¤6.67 | 04/03/2013 |
| SURCHARGE - FS 468.631 | ¤6.67 | 04/03/2013 |
| ADMIN COMMERCIAL | ¤60.00 | 04/03/2013 |
| INSPECTION - COMMERCIAL ADD | ¤100.00 | 04/03/2013 |
| ELECTRIC FEE | ¤61.44 | 04/03/2013 |
| FIRE PLANS REVIEW | ¤25.00 | 04/03/2013 |
| MECHANICAL FEE | ¤61.44 | 04/03/2013 |
| PLAN CHECK FEE | ¤100.00 | 04/03/2013 |
| PLUMBING FEE | ¤61.44 | 04/03/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤582.66 |