I want to search for...

Permit #2013030186

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7058-00250-0010
SCREEN PORCH (SOLID ROOF) : 1500 sqft
Total Square Footage: 1500 sqft
Block: 00250
Subdivision: -
Job Phone: 386-761-1763
Location Address: 72 SEVEN WONDERS TR
Type: PO - POOL
Issue Date: 04/02/2013
NOC: RECORDED
Applicant name: BROCK LINDHOLM MILLER
Owner: PUENTES, EDISON JR & MARIA C

Address

72 SEVEN WONDERS TRAIL

PALM COAST, FL 32164

Lot: 0010
Contracted Stated Job Value: ¤22,000.00
Job Description: 15 X 30 SWIMMING POOL W/ SCREENED DECK
Type: CN

Contractor

BLUE WATER POOL SUPPLIES & SERVICE
Status Location Address State License Number Phone Fax
ACTIVE

1731 S. RIDGEWOOD AVENUE

SOUTH DAYTONA, FL 32119

CPC1458142 (Exp: 08/31/2026) 386-761-1763 386-761-1763

Sub Contractors

GERALD EDWARD MASTERS JR
Status Location Address State License Number Phone
ACTIVE

505 HERBERT STREET

PORT ORANGE, FL 32129

EC13003217 (Exp: 08/31/2026) (386)304-2600
THIAGO JOSE BAGATTINI DAVILA
Status Location Address State License Number Phone Fax
INACTIVE

2211 WEST WASHINGTON STREET

ORLANDO, FL 32805

CRC1329177 (Exp: 08/30/2020) (407)237-3128 (407)237-3129

Inspection History

Type Request Date Result Inspector
ELECTRIC AND ALARM 05/23/2013 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 5/23/2013 2:54:04 PM CONDUIT FOR GFCI RECEPTACLE NEEDS TO BE 18IN DEEP WHERE NOT UNDER SLAB. NEC 2008 T300.5. PROVIDE PAPERWORK FOR LIGHT SHOWING WHERE ITS UL LISTED FOR NOT REQUIRING THE FORMING SHELL FOR LIGHT TO BE BONDED WITH A #8AWG COPPER WIRE. NEC 2008 680 PER LAST INSPECTOR...NEED TO BOND MOTER AND SUB PANEL ALSO,AND COMPLETE WIRING...NEED TO SECURE SENSOR FOR SLIDER DOOR ALARM,KEEPS FALLING AND GOING OFF ON ITS OWN,ALARMS OK.
ELECTRIC AND ALARM 05/22/2013 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 5/22/2013 1:51:26 PM NOT READY FOR INSPECTION.NEEDS TO BE READY WHEN CALLED IN FBC 110
POOL DECK 04/29/2013 APPROVED - AS NOTED RMARVEL
Note: Inspection Resulted at 4/29/2013 2:50:09 PM CONDUIT FOR GFCI RECEPTACLE NEEDS TO BE 18IN DEEP WHERE NOT UNDER SLAB. NEC 2008 T300.5. PROVIDE PAPERWORK FOR LIGHT SHOWING WHERE ITS UL LISTED FOR NOT REQUIRING THE FORMING SHELL FOR LIGHT TO BE BONDED WITH A #8AWG COPPER WIRE. NEC 2008 680. WILL NEED TO CHECK AT ELECTRIC AND ALARM INSPECTION.
STEEL AND GROUND 04/03/2013 APPROVED RMARVEL
FINAL SURVEY (OFFICE USE ONLY)
ELECTRIC AND ALARM
Note: THIS IS A REINSPECTION
POOL FINAL
ROW DAMAGE
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
ZON HOLD 09/27/2013 09/27/2013
Note: Held By: JMCGOWEN final does not match proposed site plan Held By Jgonzalez Must show setback on final survey provide elevation of planter
SW1 HOLD 09/27/2013 09/27/2013
Note: Held By: JMCGOWEN final does not match proposed site plan
ZON COMPLETE 04/01/2013 04/01/2013
ZON HOLD 03/25/2013 03/25/2013
Note: Cannot release pool permit until Screen permit is issued.
ZON COMPLETE 03/20/2013 03/25/2013
ZON HOLD 03/14/2013 03/18/2013
Note: 1. Although the rear setback of 6.5 feet appears to be met per the revised site plan (shown as 7 ft), the screen enclosure plan shows a rear setback of 6 feet. The permit for the screen enclosure barrier (2013030116) is on hold for failure to meet the required 6.5 foot rear setback. The pool plans cannot be approved at this time until the setbacks are met on the screen enclosure plan and the hold on permit 2013030116 is released. 2. The site plan shows a 3 foot sidewalk on the left side of the home. Is this a proposed sidewalk? If so, please show the linear feet of sidewalk to be constructed and clarify where the new sidewalk will end. 3. Please revise the site plan to show the dimensions of the pool equipment pad. 4. Please show on the site plan any trees to be removed, or state on the plan that no trees are to be removed to construct the pool.
BLD COMPLETE 03/08/2013 03/11/2013
SW1 COMPLETE 03/08/2013 03/08/2013
ZON HOLD 03/08/2013 03/11/2013
Note: Revise the site plan to show the setbacks.
SW1 CANCEL
ZON CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 04/02/2013
PERMIT FEE ¤160.00 04/02/2013
PLAN CHECK FEE ¤40.00 04/02/2013
SITE PLAN 20 ¤20.00 04/02/2013
SURCHARGE FS 533.721 ¤3.30 04/02/2013
SURCHARGE - FS 468.631 ¤3.30 04/02/2013
STORM WATER PERMIT FEES ¤80.00 04/02/2013
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
Fees Total Due: ¤80.00 Total Paid: ¤326.60