Permit #2013030350
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7037-01400-0030 |
| Block: 01400 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 386-931-0627 |
| Location Address: 13 LEIDEL DR |
| Type: DR - DRIVEWAY |
| Issue Date: 04/11/2013 |
| NOC: Unknown |
| Applicant name: FERNANDO FERNANDES |
| Owner: KES SOPHEATH & SINOURN T H&W |
|
Address 13 LEIDEL DRIVE PALM COAST, FL 32137 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤1,700.00 |
| Job Description: 16 FT WIDE CIRCULAR DRIVEWAY ADDITION |
| Type: CN |
Contractor
HIGH TECH CONCRETE INC
| Status | Location Address | Phone |
| CANCEL |
PO BOX 351726 BUNNELL, FL 32110 |
386-931-0627 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 09/16/2013 | FINAL APPROVED | DSPENCER |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 09/12/2013 | APPROVED | GLALIMA |
| STORMWATER FINAL | 09/12/2013 | APPROVED | CMINI |
| ROW DAMAGE | 09/12/2013 | APPROVED | GLALIMA |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/23/2013 | CANCELLED BY APPLICANT | RGROSS |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/22/2013 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/19/2013 | Disapproved -FEE REQUIRED | RGROSS |
| Note: REASON IT FAILED : Pipe Elevation is too high. The existing pipe to this circular driveway is upstream and is currently lower than the new pipe installed. If pipe is set to swale sheet Elevation, it will be lower than the existing pipe in the circular driveway and higher than the next pipe downstream. CORRECTION NEEDED : Reset pipe to proper Elevation that is determined by the swale sheet. |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 04/03/2013 | 04/04/2013 |
| UD1 | COMPLETE | 04/03/2013 | 04/03/2013 |
| Note: the revised site plan calls out for the edge of driveway to be 4ft off out side edge of PEP tank lid. Make sure that works. If not it will will fail final inspection. | |||
| ENGIN1 | COMPLETE | 03/15/2013 | 03/18/2013 |
| SW1 | COMPLETE | 03/15/2013 | 03/15/2013 |
| UD1 | HOLD | 03/15/2013 | 03/19/2013 |
| Note: the driveway can not encroach the clear zone for the PEP tank. markings on the ground shows it encroaching that clear zone. clear zone can be found on the city web site. | |||
| ZON | HOLD | 03/15/2013 | 03/18/2013 |
| Note: 1. Revise site plan to show all dimensions and setbacks for proposed driveway. 2. Revise site plan to show driveway a semicircle. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/13/2013 |
| SITE PLAN 20 | ¤20.00 | 04/11/2013 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/11/2013 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/11/2013 |
| STORM WATER PERMIT FEES | ¤40.00 | 04/11/2013 |
| ADMIN FEE | ¤20.00 | 04/11/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤124.00 |