Permit #2013040360
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7019-00030-0010 |
| ENCLOSE EXISTING PORCH TO LIVING : 476 sqft |
| Total Square Footage: 476 sqft |
| Block: 00030 |
| Subdivision: 2214 - SECTION 19-WYNNFIELD |
| Job Phone: 904-826-1426 |
| Location Address: 3 WATERS DR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 05/01/2013 |
| NOC: RECORDED |
| Applicant name: FRANK ROBERT SORRENTINO |
| Owner: JOYA, CLAUDIO |
|
Address 3 WATERS DRIVE PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤10,000.00 |
| Job Description: ENCLOSE EXISTING 14 X 34 FT REAR PORCH W/KNEEWALL, SLIDERS AND WINDOWS; REPLACE 9 WINDOWS |
| Type: CN |
Contractor
CLEAR CHOICE WINDOWS OF NORTH FLORIDA
| Status | Location Address | State License Number | Phone |
| CANCEL |
212 BEECHWOOD LANE PALM COAST, FL 32137 |
CBC1258275 (Exp: 08/31/2016) | 386-225-3304 |
Sub Contractors
JOHN FREDERICK WANERKA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 350214 BUNNELL, FL 32110 |
EC13003318 (Exp: 08/31/2022) | (386)446-9626 | (386)445-3131 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/02/2013 | FINAL APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 06/26/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 6/26/2013 2:46:05 PM 2 WINDOWS ARE MISSING 3 SCREWS EACH ON BOTTOM. INSTALL TO APPROVED PLANS. | |||
| ALL ROUGH | 06/25/2013 | APPROVED | RMARVEL |
| TIE BEAM / LINTEL | 05/31/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| TIE BEAM / LINTEL | 05/29/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/29/2013 3:17:41 PM FORMS MUST BE IN PLACE TO DETERMINE COVERAGE FOR STEEL-REINFORCING STEEL MUST BE ABOVE MASONRY AT BOTTOM PER FBC-RESIDENTIAL 606.9.5 | |||
| TIE BEAM / LINTEL | 05/23/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 5/23/2013 12:17:20 PM FORMS MUST BE IN PLACE TO DETERMINE COVERAGE FOR STEEL-REINFORCING STEEL MUST BE ABOVE MASONRY AT BOTTOM PER FBC-RESIDENTIAL 606.9.5 |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 04/25/2013 | 04/30/2013 |
| ELEC | COMPLETE | 04/23/2013 | 04/23/2013 |
| BLD | COMPLETE | 04/23/2013 | 04/23/2013 |
| ZON | HOLD | 04/23/2013 | 04/23/2013 |
| Note: 1. Previous comment still applies: Please provide a site plan based on a survey showing the entire lot with all improvements on the property, along with location and dimensions of the proposed patio to be enclosed. Please also include setback distances from all surrounding property lines. Please see Zoning for assistance with the site plan if a current survey is not available. | |||
| BLD | HOLD | 04/12/2013 | 04/15/2013 |
| Note: 1. Provide detail to show that the master bedroom meets emergency opening requirements. per 2010 FBC 310 | |||
| ELEC | HOLD | 04/12/2013 | 04/15/2013 |
| Note: Provide scope of work FBC 107.2.1 provide receptacle and lighting locations NEC 210.52 and 210.70 | |||
| ZON | HOLD | 04/12/2013 | 04/15/2013 |
| Note: 1. Please provide a site plan based on a survey showing all improvements on the property, along with location and dimensions of the proposed patio to be enclosed. Please also include setback distances from all surrounding property lines. 2. Please provide a building elevation sufficient in detail to review exterior wall finishes (e.g. stucco) and paint colors in the area of proposed work. Please note that per LDC Sec 13.02, finishes for the proposed new exterior walls must match that of the primary structure, and exterior paint colors must comply with Section 13.02.06, or state on the elevation that the new walls will be painted to match the existing structure. Per Sec. 13.02.07, exposed concrete block is prohibited. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/01/2013 |
| REINSPECTION FEE | ¤40.00 | 05/30/2013 |
| REINSPECTION FEE | ¤40.00 | 05/28/2013 |
| ADMIN FEE | ¤20.00 | 05/01/2013 |
| ELECTRIC FEE | ¤79.20 | 05/01/2013 |
| PLAN CHECK FEE | ¤40.00 | 05/01/2013 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 05/01/2013 |
| SITE PLAN 20 | ¤20.00 | 05/01/2013 |
| SURCHARGE FS 533.721 | ¤2.69 | 05/01/2013 |
| SURCHARGE - FS 468.631 | ¤2.69 | 05/01/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤324.58 |