I want to search for...
Permit #2013040671
Permit Details
Status: COED
| Parcel Id: 48-11-31-1710-00000-0070 |
| CONDITIONED SPACE: 2924 sqft |
| GARAGE: 1031 sqft |
| SCREEN PORCH (SOLID ROOF) : 824 sqft |
| OPENED PORCH (WITH ROOF) : 55 sqft |
| Total Square Footage: 4834 sqft |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: 386-947-4481 |
| Location Address: 188 WILLOW OAK WAY |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/09/2013 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: BOLDUC, RICHARD A & LORNA M |
|
Address 17 RIVENDELL ROAD MARLBOROUGH, CT 06447 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BENJAMIN EDWARD SMITH
| Status | Location Address | State License Number | Phone |
| CANCEL |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13004288 (Exp: 08/31/2016) | 386-265-2687 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/20/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | DROCKWELL |
| Note: Inspection Resulted at 12/20/2013 3:33:50 PM MISSING HOUSE NUMBERS | |||
| U -UTILITY RESIDENTIAL FINAL | 12/20/2013 | FINAL APPROVED | DSPENCER |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 12/19/2013 | APPROVED | GLALIMA |
| ROW FINAL | 12/19/2013 | APPROVED | GLALIMA |
| FINAL SURVEY (OFFICE USE ONLY) | 12/19/2013 | APPROVED | RLEE |
| ELECTRIC - EARLY POWER | 11/07/2013 | Disapproved - NO FEE | CMINI |
| Note: Inspection Resulted at 11/7/2013 3:27:38 PM CAN NOT CONDUCT EARLY POWER INSPECTION PER BUILDING OFFICIAL,DUE TO OUTSTANDING CODE VIOLATIONS THAT WERE NOT ADDRESSED TO B.D. FROM ALL ROUGH | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 11/01/2013 | APPROVED | GLALIMA |
| Note: 2 PART INSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 10/29/2013 | PARTIALLY APPROVED | GLALIMA |
| Note: READY FOR CONCRETE , WAITING ON ROADBASE | |||
| INSULATION | 08/27/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 8/27/2013 2:26:37 PM REVISIONS FOR CHANGES NEED TO BE SUBMITTED FOR DELETED AND ADDED ELECTRIC TO BUILDING DEPT FOR CORRECTIONS ON LIST,LUGS AND GROUND SCREWS CORRECTED | |||
| INSULATION | 08/20/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 8/20/2013 2:43:28 PM ITEMS FROM ALL ROUGH NOT CORRECTED,INSULATION COMPLETE approved by Mike Navarra | |||
| ALL ROUGH | 08/16/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 8/16/2013 3:05:08 PM AUDIT...ELECTRIC:MISSING GROUNDS IN METAL BOXES.NEC.314.4..LUGS IN SECONDARY PANEL NOT TORQURED.LOOSE CONDUCTORS..REVISION NEEDED TO SHOW LIGHTS ADDEDS AS WELL AS OUTLETS..PLAN ALSO SHOWS OUTLETS FOR ABOVE DOOR FOR FUTURE BLINDS,CAN NOT LOCATE THEM...PLUMBING: NEED TO HAVE 5`` HEAD PRESSURE..FBC P2503.4..CANNOT LOCATE GAS RISER DIAGRAM...FBC 105.7..INSULATION HAS STARTED failed by Robert Waldrop Install LGT @1GE SPECIAL PPI 4. Bond Security Panel 3. Intall tap cons in front wall Partial Rejected 2. Entry Straps | |||
| LATH/BRICK/ WATER BARRIER | 08/13/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | DROCKWELL |
| Note: Inspection Resulted at 8/13/2013 2:38:07 PM LATH APPROVED approved by Robert Waldrop | |||
| ELECTRIC - EARLY POWER | 07/11/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 7/11/2013 3:36:54 PM TUG ELECTRIC..CALLED FPL TO RELEASE POWER AT 2:00 SPOKE WIITH SUSAN approved by Mike Navarra | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/28/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | DROCKWELL |
| Note: Inspection Resulted at 6/28/2013 2:35:26 PM TRUSS/WALL STRAPPING NOT COMPLETED THRU-OUT/BEARING WALLS NOT BLOCKED MID POINT/2X BEARING WALL PLATES NOT BOLTED/INTERIOR GIRDERS NOT ANCHORED TO BEARING WALLS/PROVIDE FRAMING DETAIL FOR MITERED GLASS SECTION/NOT READY FOR INSPECTION/INCOMPLETE INSPECTION | |||
| GRAVITY SEWER TEST | 06/21/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 6/21/2013 3:02:55 PM NEED TO UNCOVER WORK TO BE INSPECTED..FBC...P2503.2 approved by Brian Pohl | |||
| U - SEWER TIE IN | 06/21/2013 | APPROVED | DSPENCER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/20/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 6/20/2013 2:44:55 PM NOT READY FOR ROOF SHEATHING BRACES,TIES AND DOWN CELL AUDIT..ROOF NEEDS TO BE VALLEY FLASHED AND DRIP EDGE ON,ANCHORS MISSING,STRAPS MISSING,WALL SHEATHING NOT COMPLETE. approved by Robert Waldrop | |||
| ELEV CERT-FOUNDATION APPROVAL | 06/19/2013 | APPROVED | CBENTLEY |
| FOUND SURVEY APPROVED (OFFICE) | 06/19/2013 | APPROVED | JMCGOWEN |
| TIE BEAM / LINTEL | 06/06/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 6/6/2013 2:18:01 PM OK approved by Robert Waldrop | |||
| MONOLITHIC SLAB | 05/24/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: approved by Mike Navarra and approved plumbing Inspection Resulted at 5/24/2013 12:53:28 PM COULD NOT CONDUCT AUDIT SLAB ALREADY PLACED | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/17/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 5/17/2013 3:14:24 PM NOT HOLDING 5`` TEST ON DWV..FBC P2503.4 failed by Mike Navarra for leak |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 12/20/2013 | 12/20/2013 |
| SW1 | COMPLETE | 12/19/2013 | 12/20/2013 |
| Note: Released By: JMCGOWEN FINAL SURVEY | |||
| ELEC | COMPLETE | 09/10/2013 | 09/10/2013 |
| ZON | COMPLETE | 06/06/2013 | 06/11/2013 |
| PLFM | COMPLETE | 06/06/2013 | 06/19/2013 |
| SW1 | COMPLETE | 06/03/2013 | 06/03/2013 |
| Note: Released By: JHINDMAN FOUNDATION SURVEY | |||
| ZON | HOLD | 06/03/2013 | 06/03/2013 |
| Note: Held By: JHINDMAN FOUNDATION SURVEY 1. Provide a revised site plan due to the elevation not matching the approved plans. | |||
| DSD | COMPLETE | 05/31/2013 | 06/19/2013 |
| Note: no DSD review required | |||
| SW1 | COMPLETE | 05/31/2013 | 05/31/2013 |
| Note: Released By: JHINDMAN foundation survey | |||
| ZON | HOLD | 05/31/2013 | 05/31/2013 |
| Note: Held By: JHINDMAN foundation survey 1. The elevation does not match the approved plans. J. Hindman | |||
| ELEC | COMPLETE | 05/01/2013 | 05/01/2013 |
| BLD | COMPLETE | 05/01/2013 | 05/01/2013 |
| MECH | COMPLETE | 05/01/2013 | 05/02/2013 |
| ZON | COMPLETE | 05/01/2013 | 05/03/2013 |
| PLFM | COMPLETE | 05/01/2013 | 05/03/2013 |
| PLFM | HOLD | 04/26/2013 | 04/29/2013 |
| Note: Held By: CBENTLEY 1. Section D has a statment that the elevation certificate consist of 2 pages on 1 sheet however it also mentions an attached Section H for additional comments. There is no Section H attached. Either provide Section H and change to 2 pages on 2 sheets or remove Section H statement fromt he comments. 2. No signature is required in Section F. | |||
| BLD | HOLD | 04/24/2013 | 04/24/2013 |
| Note: 1. Provide header details for the interior bearing walls. 2010 FBC R602.7. 2. Provide manufacturers specifications for the Fireplace. 2010 FBC 107.2.1. 3. Coordinate drawings the floorplan calls for a future firepit on the patio but the gas riser does not show the piping. 2010 FBC 107.2.1. | |||
| ELEC | HOLD | 04/24/2013 | 04/24/2013 |
| Note: Revise receptacle locations to meet NEC 210.52 revise riser detail to meet the electric calculation requirement FBC 107.2.1 | |||
| ENGIN1 | COMPLETE | 04/24/2013 | 04/24/2013 |
| Note: No swale plan required. | |||
| MECH | HOLD | 04/24/2013 | 04/24/2013 |
| Note: 1. Hvac plan shows notes and detail not related to hvac which are not allowed per 2010 FBC 107.2.1. 2. Number of bedroom shown on energy calculation does not match with plans. Coordinate and revise per 2010 FBC 107.2.1. | |||
| PLUM | COMPLETE | 04/24/2013 | 04/24/2013 |
| SW1 | COMPLETE | 04/24/2013 | 04/24/2013 |
| UD1 | COMPLETE | 04/24/2013 | 04/24/2013 |
| URB | COMPLETE | 04/24/2013 | 04/25/2013 |
| ZON | HOLD | 04/24/2013 | 04/26/2013 |
| Note: Revise landscape plan to remove future spa add landscaping in the rear. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 12/27/2013 |
| SITE PLAN 20 | ¤20.00 | 05/09/2013 |
| SURCHARGE FS 533.721 | ¤27.32 | 05/09/2013 |
| SURCHARGE - FS 468.631 | ¤27.32 | 05/09/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/09/2013 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 05/09/2013 |
| ADMIN FEE | ¤20.00 | 05/09/2013 |
| ELECTRIC FEE | ¤291.60 | 05/09/2013 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 05/09/2013 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 05/09/2013 |
| IMPACT FEE PARKS | ¤1,343.98 | 05/09/2013 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/09/2013 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 05/09/2013 |
| MECHANICAL FEE | ¤291.60 | 05/09/2013 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 05/09/2013 |
| PLAN CHECK FEE | ¤154.40 | 05/09/2013 |
| PLUMBING FEE | ¤291.60 | 05/09/2013 |
| NEW RESIDENTIAL INSPECTIONS | ¤772.00 | 05/09/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,047.79 |