I want to search for...

Permit #2013040671

Permit Details

Status: COED

Parcel Id: 48-11-31-1710-00000-0070
CONDITIONED SPACE: 2924 sqft
GARAGE: 1031 sqft
SCREEN PORCH (SOLID ROOF) : 824 sqft
OPENED PORCH (WITH ROOF) : 55 sqft
Total Square Footage: 4834 sqft
Block: 00000
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: 386-947-4481
Location Address: 188 WILLOW OAK WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/09/2013
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: BOLDUC, RICHARD A & LORNA M

Address

17 RIVENDELL ROAD

MARLBOROUGH, CT 06447

Lot: 0070
Contracted Stated Job Value: ¤300,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/20/2013 AUDIT - PRIVATE PROVIDER INSPECTION DROCKWELL
Note: Inspection Resulted at 12/20/2013 3:33:50 PM MISSING HOUSE NUMBERS
U -UTILITY RESIDENTIAL FINAL 12/20/2013 FINAL APPROVED DSPENCER
FINAL APRON (AFTER POUR/DRIVEWAY) 12/19/2013 APPROVED GLALIMA
ROW FINAL 12/19/2013 APPROVED GLALIMA
FINAL SURVEY (OFFICE USE ONLY) 12/19/2013 APPROVED RLEE
ELECTRIC - EARLY POWER 11/07/2013 Disapproved - NO FEE CMINI
Note: Inspection Resulted at 11/7/2013 3:27:38 PM CAN NOT CONDUCT EARLY POWER INSPECTION PER BUILDING OFFICIAL,DUE TO OUTSTANDING CODE VIOLATIONS THAT WERE NOT ADDRESSED TO B.D. FROM ALL ROUGH
PRE-APRON (PRE-POUR/DRIVEWAY) 11/01/2013 APPROVED GLALIMA
Note: 2 PART INSPECTION
PRE-APRON (PRE-POUR/DRIVEWAY) 10/29/2013 PARTIALLY APPROVED GLALIMA
Note: READY FOR CONCRETE , WAITING ON ROADBASE
INSULATION 08/27/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 8/27/2013 2:26:37 PM REVISIONS FOR CHANGES NEED TO BE SUBMITTED FOR DELETED AND ADDED ELECTRIC TO BUILDING DEPT FOR CORRECTIONS ON LIST,LUGS AND GROUND SCREWS CORRECTED
INSULATION 08/20/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 8/20/2013 2:43:28 PM ITEMS FROM ALL ROUGH NOT CORRECTED,INSULATION COMPLETE approved by Mike Navarra
ALL ROUGH 08/16/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 8/16/2013 3:05:08 PM AUDIT...ELECTRIC:MISSING GROUNDS IN METAL BOXES.NEC.314.4..LUGS IN SECONDARY PANEL NOT TORQURED.LOOSE CONDUCTORS..REVISION NEEDED TO SHOW LIGHTS ADDEDS AS WELL AS OUTLETS..PLAN ALSO SHOWS OUTLETS FOR ABOVE DOOR FOR FUTURE BLINDS,CAN NOT LOCATE THEM...PLUMBING: NEED TO HAVE 5`` HEAD PRESSURE..FBC P2503.4..CANNOT LOCATE GAS RISER DIAGRAM...FBC 105.7..INSULATION HAS STARTED failed by Robert Waldrop Install LGT @1GE SPECIAL PPI 4. Bond Security Panel 3. Intall tap cons in front wall Partial Rejected 2. Entry Straps
LATH/BRICK/ WATER BARRIER 08/13/2013 AUDIT - PRIVATE PROVIDER INSPECTION DROCKWELL
Note: Inspection Resulted at 8/13/2013 2:38:07 PM LATH APPROVED approved by Robert Waldrop
ELECTRIC - EARLY POWER 07/11/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 7/11/2013 3:36:54 PM TUG ELECTRIC..CALLED FPL TO RELEASE POWER AT 2:00 SPOKE WIITH SUSAN approved by Mike Navarra
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/28/2013 AUDIT - PRIVATE PROVIDER INSPECTION DROCKWELL
Note: Inspection Resulted at 6/28/2013 2:35:26 PM TRUSS/WALL STRAPPING NOT COMPLETED THRU-OUT/BEARING WALLS NOT BLOCKED MID POINT/2X BEARING WALL PLATES NOT BOLTED/INTERIOR GIRDERS NOT ANCHORED TO BEARING WALLS/PROVIDE FRAMING DETAIL FOR MITERED GLASS SECTION/NOT READY FOR INSPECTION/INCOMPLETE INSPECTION
GRAVITY SEWER TEST 06/21/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 6/21/2013 3:02:55 PM NEED TO UNCOVER WORK TO BE INSPECTED..FBC...P2503.2 approved by Brian Pohl
U - SEWER TIE IN 06/21/2013 APPROVED DSPENCER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 6/20/2013 2:44:55 PM NOT READY FOR ROOF SHEATHING BRACES,TIES AND DOWN CELL AUDIT..ROOF NEEDS TO BE VALLEY FLASHED AND DRIP EDGE ON,ANCHORS MISSING,STRAPS MISSING,WALL SHEATHING NOT COMPLETE. approved by Robert Waldrop
ELEV CERT-FOUNDATION APPROVAL 06/19/2013 APPROVED CBENTLEY
FOUND SURVEY APPROVED (OFFICE) 06/19/2013 APPROVED JMCGOWEN
TIE BEAM / LINTEL 06/06/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 6/6/2013 2:18:01 PM OK approved by Robert Waldrop
MONOLITHIC SLAB 05/24/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: approved by Mike Navarra and approved plumbing Inspection Resulted at 5/24/2013 12:53:28 PM COULD NOT CONDUCT AUDIT SLAB ALREADY PLACED
PLUMBING 1ST ROUGH UNDERGROUND 05/17/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 5/17/2013 3:14:24 PM NOT HOLDING 5`` TEST ON DWV..FBC P2503.4 failed by Mike Navarra for leak

Review History

Department Status Date In Date Out
PLFM COMPLETE 12/20/2013 12/20/2013
SW1 COMPLETE 12/19/2013 12/20/2013
Note: Released By: JMCGOWEN FINAL SURVEY
ELEC COMPLETE 09/10/2013 09/10/2013
ZON COMPLETE 06/06/2013 06/11/2013
PLFM COMPLETE 06/06/2013 06/19/2013
SW1 COMPLETE 06/03/2013 06/03/2013
Note: Released By: JHINDMAN FOUNDATION SURVEY
ZON HOLD 06/03/2013 06/03/2013
Note: Held By: JHINDMAN FOUNDATION SURVEY 1. Provide a revised site plan due to the elevation not matching the approved plans.
DSD COMPLETE 05/31/2013 06/19/2013
Note: no DSD review required
SW1 COMPLETE 05/31/2013 05/31/2013
Note: Released By: JHINDMAN foundation survey
ZON HOLD 05/31/2013 05/31/2013
Note: Held By: JHINDMAN foundation survey 1. The elevation does not match the approved plans. J. Hindman
ELEC COMPLETE 05/01/2013 05/01/2013
BLD COMPLETE 05/01/2013 05/01/2013
MECH COMPLETE 05/01/2013 05/02/2013
ZON COMPLETE 05/01/2013 05/03/2013
PLFM COMPLETE 05/01/2013 05/03/2013
PLFM HOLD 04/26/2013 04/29/2013
Note: Held By: CBENTLEY 1. Section D has a statment that the elevation certificate consist of 2 pages on 1 sheet however it also mentions an attached Section H for additional comments. There is no Section H attached. Either provide Section H and change to 2 pages on 2 sheets or remove Section H statement fromt he comments. 2. No signature is required in Section F.
BLD HOLD 04/24/2013 04/24/2013
Note: 1. Provide header details for the interior bearing walls. 2010 FBC R602.7. 2. Provide manufacturers specifications for the Fireplace. 2010 FBC 107.2.1. 3. Coordinate drawings the floorplan calls for a future firepit on the patio but the gas riser does not show the piping. 2010 FBC 107.2.1.
ELEC HOLD 04/24/2013 04/24/2013
Note: Revise receptacle locations to meet NEC 210.52 revise riser detail to meet the electric calculation requirement FBC 107.2.1
ENGIN1 COMPLETE 04/24/2013 04/24/2013
Note: No swale plan required.
MECH HOLD 04/24/2013 04/24/2013
Note: 1. Hvac plan shows notes and detail not related to hvac which are not allowed per 2010 FBC 107.2.1. 2. Number of bedroom shown on energy calculation does not match with plans. Coordinate and revise per 2010 FBC 107.2.1.
PLUM COMPLETE 04/24/2013 04/24/2013
SW1 COMPLETE 04/24/2013 04/24/2013
UD1 COMPLETE 04/24/2013 04/24/2013
URB COMPLETE 04/24/2013 04/25/2013
ZON HOLD 04/24/2013 04/26/2013
Note: Revise landscape plan to remove future spa add landscaping in the rear.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 12/27/2013
SITE PLAN 20 ¤20.00 05/09/2013
SURCHARGE FS 533.721 ¤27.32 05/09/2013
SURCHARGE - FS 468.631 ¤27.32 05/09/2013
STORM WATER PERMIT FEES ¤80.00 05/09/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 05/09/2013
ADMIN FEE ¤20.00 05/09/2013
ELECTRIC FEE ¤291.60 05/09/2013
3% FIRE IMPACT FEE CREDIT (¤6.24) 05/09/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 05/09/2013
IMPACT FEE PARKS ¤1,343.98 05/09/2013
IMPACT FEE SCHOOL ¤3,600.00 05/09/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 05/09/2013
MECHANICAL FEE ¤291.60 05/09/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 05/09/2013
PLAN CHECK FEE ¤154.40 05/09/2013
PLUMBING FEE ¤291.60 05/09/2013
NEW RESIDENTIAL INSPECTIONS ¤772.00 05/09/2013
Fees Total Due: ¤0.00 Total Paid: ¤10,047.79