I want to search for...
Permit #2013050154
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7009-00160-0320 |
| CONDITIONED SPACE: 397 sqft |
| PATIO/DECK (NO ROOF) : 43 sqft |
| Total Square Footage: 440 sqft |
| Block: 00160 |
| Subdivision: 2208 - SECTION 9-FLORIDA PARK |
| Job Phone: (386)445-9055 |
| Location Address: 4 FAIRBANK LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 06/06/2013 |
| NOC: RECORDED |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: RODRIGUES, JOAO C & ELISA |
|
Address 4 FAIRBANK LANE PALM COAST, FL 32137 |
| Lot: 0320 |
| Contracted Stated Job Value: ¤8,500.00 |
| Job Description: 31 X 12.67 BUILDING ADDITION AND 8.5 X 4 CONCRETE PAD |
| Type: CN |
Contractor
NEW COASTAL HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
399 SW PALM COAST PKWY PALM COAST, FL 32137 |
STE5 PALM COAST, FL 32137 |
CRC1327024 (Exp: 08/31/2018) | (386)445-9055 | (386)445-9056 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
THOMAS CHARLES TALLAKSEN JR.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
503 SOUTH OLD DIXIE HWY BUNNELL, FL 32110 |
CCC1327743 (Exp: 08/31/2024) | 386-931-2990 | (386)437-2279 |
THOMAS CHARLES TALLAKSEN JR.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
503 SOUTH OLD DIXIE HWY BUNNELL, FL 32110 |
CCC1327743 (Exp: 08/31/2024) | 386-931-2990 | (386)437-2279 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 05/21/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 05/20/2014 | FINAL APPROVED | CMINI |
| FINAL SURVEY (OFFICE USE ONLY) | 05/16/2014 | APPROVED | FREODICA |
| LATH/BRICK/ WATER BARRIER | 12/03/2013 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 11/22/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 11/22/2013 3:04:25 PM EXPOSED WOOD JAMBS NOT PREPED FOR STUCCO APPLICATION. | |||
| INSULATION | 11/20/2013 | APPROVED | CMINI |
| ALL ROUGH | 11/12/2013 | APPROVED | DROCKWELL |
| FRAMING | 11/12/2013 | APPROVED | DROCKWELL |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/14/2013 | APPROVED | DROCKWELL |
| TIE BEAM / LINTEL | 07/23/2013 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 07/22/2013 | APPROVED | JMCGOWEN |
| MONOLITHIC SLAB | 06/17/2013 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/16/2014 | 05/16/2014 |
| Note: Released By: FREODICA Final survey correction but can not edit inspection due to invalid NOC. | |||
| SW1 | HOLD | 05/12/2014 | 05/13/2014 |
| Note: Held By: JMCGOWEN final survey Provide drainage elevations on survey for review COPC storm water | |||
| BLD | COMPLETE | 11/06/2013 | 11/06/2013 |
| ELEC | COMPLETE | 11/06/2013 | 11/06/2013 |
| ZON | COMPLETE | 07/22/2013 | 07/22/2013 |
| Note: Released By: JMCGOWEN foundation survey | |||
| SW1 | COMPLETE | 07/22/2013 | 07/22/2013 |
| Note: Released By: JMCGOWEN foundation survey | |||
| MECH | COMPLETE | 06/05/2013 | 06/06/2013 |
| MECH | HOLD | 05/22/2013 | 05/22/2013 |
| Note: 1. The existing porch and the newly proposed enclosed covered porch addition/extension is classified as a living space. Provide energy calculations and heating and/or cooling per 2010 FBC R 301.2.1.1.2. | |||
| ELEC | COMPLETE | 05/22/2013 | 05/22/2013 |
| BLD | COMPLETE | 05/22/2013 | 05/22/2013 |
| ZON | COMPLETE | 05/22/2013 | 05/29/2013 |
| SW1 | COMPLETE | 05/22/2013 | 05/22/2013 |
| BLD | HOLD | 05/06/2013 | 05/07/2013 |
| Note: 1. Provide a emergency egress window for the master bedroom. 2010 FBC R310. 2. The provided plans call for roof trusses and also show 2 x 12 joists. Coordinate plans and provide the correct detail and all engineering required. 2010 FBC 107.2.1. | |||
| ELEC | HOLD | 05/06/2013 | 05/07/2013 |
| Note: Revise receptacle locations to meet NEC 210.52 locate lighting outlets NEC 210.70 | |||
| SW1 | COMPLETE | 05/06/2013 | 05/07/2013 |
| ZON | HOLD | 05/06/2013 | 05/09/2013 |
| Note: Clarify access from storage area to main living area. Revise site plan to show all door pads. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 05/20/2014 |
| REINSPECTION FEE | ¤40.00 | 05/20/2014 |
| REVISION | ¤40.00 | 05/20/2014 |
| REVISION | ¤40.00 | 05/20/2014 |
| SITE PLAN 20 | ¤20.00 | 06/06/2013 |
| SURCHARGE FS 533.721 | ¤2.80 | 06/06/2013 |
| SURCHARGE - FS 468.631 | ¤2.80 | 06/06/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/06/2013 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 06/06/2013 |
| ELECTRIC FEE | ¤86.40 | 06/06/2013 |
| PLAN CHECK FEE | ¤40.00 | 06/06/2013 |
| ADMIN FEE | ¤20.00 | 06/06/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤452.00 |