I want to search for...

Permit #2013050234

Permit Details

Status: COED

Parcel Id: 08-12-31-5835-00000-0010
CONDITIONED SPACE: 3477 sqft
OPENED PORCH (WITH ROOF) : 307 sqft
Total Square Footage: 3784 sqft
Block: 00000
Subdivision: 2117 - Town Center Phase III, BROOKHAVEN
Job Phone: 407-741-8500
Location Address: 152 BROOKHAVEN CT N
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 09/27/2013
NOC: RECORDED
Applicant name: SCOTT W CULP
Owner: BROOKHAVEN DEVELOPMENT LAND LTD

Address

200 E CANTON AVE # 102

WINTER PARK, FL 32789

Lot: 0010
Contracted Stated Job Value: ¤134,222.00
Job Description: BUILDING 27 - BROOKHAVEN 3 UNIT APARTMENT
Type: CN

Contractor

CPG CONSTRUCTION LLP
Status Location Address State License Number Phone Fax
CANCEL

200 E CANTON AVE # 102

WINTER PARK, FL 32789

CGC1512998 (Exp: 08/31/2016) 407-741-8500 407-643-2551

Sub Contractors

RANCE F BORDERICK
Status Location Address State License Number Phone Fax
ACTIVE

430 WEST DRIVE

ALTAMONTE SPRINGS, FL 32714

EC0000981 (Exp: 08/31/2026) (407)788-3500 407-788-2007
DAVID A CROSON
Status Location Address State License Number Phone Fax
CANCEL

31550 COUNTY ROAD 437

SORRENTO, FL 32776

CFC1426109 (Exp: 08/31/2022) 352-729-7100 352-735-0623
JOSEPH RICHARD CASSIDY JR
Status Location Address State License Number Phone Fax
CANCEL

17304 PHIL C PETERS RD

WINTER GARDEN, FL 34787

CCC1327385 (Exp: 08/31/2020) 407-654-4426 (407)654-4307
JOHN MAXEN BARTKOVICH
Status Location Address State License Number Phone
ACTIVE

818 SHADOWMOSS DR

WINTERGARDEN, FL 32787

CAC1815793 (Exp: 08/31/2026) 407-886-3729

Inspection History

Type Request Date Result Inspector
LDSC- LANDSCAPE FINAL 04/16/2014 APPROVED - AS NOTED WBUTLER
Note: THIS IS A REINSPECTION Per Bill Butler approved with the follow notes: LANDSCAPE/ IRRIGATION FINALS FOR BROOKHAVEN BUILDINGS 26 and 27 Permit number 2013050233 (building 26) Permit number 2013050234 (building 27) 4-16-14 NOTE: THESE ITEMS WERE OUTSTANDING FROM THE LAST INSPECTION OF BUILDINGS 6, 7 AND 8. NEED TO REINSPECT AT THE NEXT BUILDING GROUP STAGE INSPECTION. 1. Need to build earthen watering dams around all trees to contain water from bubblers. 2. All splash blocks that empty directly into planting beds need to be removed and downspout extensions are to be installed to reach the edge of the lawn. Some areas may require the shifting of the foundation plants to provide a straight shot from the building to the grass. 3. In front of buildings 6, 7 and 8, need to install the correct nozzle ("G") to irrigate the sodded area. There are two in front of each building. 4. Need purple bubblers on all trees. Some of the paint on the PGJ heads is coming off so need to replace with factory purple heads. NEW COMMENTS FOR BUILDINGS 26 and 27: 1. Plant sizes that were installed are not per the approved plan or approved e-mail revisions. An e-mail was received from Ivan Maranan on 3/12/14 asking for the following changes to be made concerning plant material: - The foundation plantings around the buildings of viburnum suspensum have been changed to viburnum odoritissum (30" ht. x 24" spread, 36" o.c. - The dwarf Asiatic jasmine has been changed from 3 gallon to 1 gallon. - The ligustrum has been changed from 12' x 12" to 8' x 8' - Mulch has been changed from 3"depth to 2" depth Bill Butler approved all of these changes the same day and just noted that they be picked up on the as-built drawings. What was discovered in the field at the inspection were some viburnum suspensum in 3 gallon containers that were barely 24 inch tall screening the parking lot area between buildings 26 and 27 on the south side. The plans call for viburnum suspensum, 7 gallon, 30 inch height. Either change these plants to viburnum odoritissum that are 30 inches tall, or podocarpus 30 inches tall. 2. The parking lot was modified to use environmental curbing instead of 6 inch highback curb. Need to add parking stops for the cars and additionally add two parking stops on each side of the parking lot along the northern edge of the two northernmost parking spaces that are adjacent to the landscape islands to prevent cars from entering the islands. 3. Add Bahia sod along the north side of the crown grass planting adjacent to the wetland buffer anywhere there is bare soil. 4. Irrigation bubblers need to be purple for re-use irrigation. 5. Any downspouts that dump water into the planting beds need to have the splash blocks removed and downspout extensions added to carry water directly to the turf areas. Shrubs may need to be shifted as some are right in front of the downspout discharge. 6. At the south side of building 26, need to shift the podocarpus plantings to be a minimum of 2 foot from the water meter boxes to allow future access. 7. Need to build earthen watering dams around all trees to contain water from bubblers. 8. Missing the two G nozzle heads at the east and west sides of the entrance to the parking lot in the 2 foot wide strip between the sidewalk and the street. 9. Need to install flush plugs on all drip irrigation areas. Plugs should be in a 6" diameter valve box. 10. On the east side of building 27, need to add more ligustrum shrubs and curve the foundation plantings out to allow a minimum of 4' clearance to the electrical panel boxes on the wall. 11. On the southwest side of building 26, missing five spray heads (symbol w), that are intended to irrigate the sod. 12. These punchlist items will be reinspected at the time of the next inspection. The first four comments from the first inspection MUST be all completed by that time; otherwise no further landscape inspections will be approved. 13. Landscape and irrigation as-builts will be required for all units prior to the final inspection approval of the last building.
U - UTILITY COMMERCIAL FINAL 04/14/2014 FINAL APPROVED DSPENCER
LDSC- LANDSCAPE FINAL 04/14/2014 CANCELLED BY APPLICANT WBUTLER
Note: cancelled by Kevin Sutton. 263-2934
FIRE FINAL 04/11/2014 APPROVED JHINDMAN
BUILDING FINAL 04/10/2014 APPROVED RMARVEL
PLUMBING FINAL 04/10/2014 APPROVED RMARVEL
HVAC FINAL 04/10/2014 APPROVED RMARVEL
ELECTRIC FINAL 04/10/2014 APPROVED RMARVEL
ELECTRIC - EARLY POWER 04/02/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 4/2/2014 3:48:36 PM CALLED FPL AT 11:35
ELECTRIC - EARLY POWER 03/25/2014 CANCELLED BY APPLICANT JHINDMAN
FIREWALL 02/19/2014 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
INSULATION 02/17/2014 APPROVED JHINDMAN
ALL ROUGH 02/14/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ALL ROUGH 02/13/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 2/13/2014 3:41:40 PM NOT READY. WORK IN PROGRESS.
FIREWALL 02/13/2014 PARTIALLY APPROVED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 2/13/2014 3:41:40 PM FIRE WALL AT TRUSS LEVEL PAINTED AT ROOF.
WINDOW NAILING 02/10/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
WINDOW NAILING 02/07/2014 CANCELLED BY APPLICANT JHINDMAN
LATH/BRICK/WATER BARRIER 02/06/2014 APPROVED JHINDMAN
GRAVITY SEWER 01/27/2014 APPROVED JHINDMAN
U - SEWER TIE IN 01/27/2014 APPROVED DSPENCER
FIREWALL 01/07/2014 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 1/7/2014 12:20:12 PM MUD AND TAPE
ELECTRIC 1ST ROUGH 01/07/2014 APPROVED RMARVEL
EXTERIOR WALL SHEATHING / SHEARWALL 12/31/2013 APPROVED RMARVEL
FIREWALL 12/31/2013 PARTIALLY APPROVED JHINDMAN
Note: Inspection Resulted at 12/31/2013 12:33:13 PM FIREWALL ATTIC SCREWS
ROOF SHEATHING / BRACE / TIE DOWN 12/27/2013 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACE / TIE DOWN 12/26/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 12/26/2013 3:37:29 PM NOT READY FOR INSPECTION
ROOF SHEATHING / BRACE / TIE DOWN 12/04/2013 CANCELLED BY APPLICANT DROCKWELL
EXTERIOR STRAP/CLIP 11/12/2013 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 11/12/2013 3:30:36 PM MISSING EXTERIOR CLIPS
MONOLITHIC SLAB 10/24/2013 APPROVED CMINI
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 10/23/2013 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 10/23/2013 3:12:21 PM NEED TO MAINTAIN 20" DEPTH ON EXTERIOR FOOTERS NOT MET
ELECTRIC 1ST ROUGH 10/23/2013 APPROVED CMINI
PLUMBING 1ST ROUGH 10/18/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH 10/17/2013 CANCELLED BY APPLICANT RMARVEL
ELECTRIC TEMP POLE 10/17/2013 APPROVED RMARVEL

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/26/2014 03/26/2014
ELEC COMPLETE 01/08/2014 01/08/2014
FI1 COMPLETE 12/30/2013 12/30/2013
Note: Released By: JHINDMAN
BLD COMPLETE 12/26/2013 12/27/2013
FI1 HOLD 12/26/2013 12/27/2013
Note: 1. provide fire reatardant letter.
BLD HOLD 12/19/2013 12/20/2013
Note: 1. Provide the correct strap ID for the Other straps. 2010 FBC 107.2.1.
ELEC COMPLETE 12/19/2013 12/19/2013
MECH COMPLETE 12/19/2013 12/20/2013
Note: Revision - Rev 4, Sheets AM2.1a/3.3
PLUM COMPLETE 12/19/2013 12/20/2013
Note: Rev 4, Sheets AP3.12/3.2/3.3/4.1
BLD COMPLETE 12/12/2013 12/13/2013
Note: Released By: JMCGOWEN Truss repair
BLD COMPLETE 12/11/2013 12/11/2013
ELEC COMPLETE 12/11/2013 12/11/2013
MECH COMPLETE 12/11/2013 12/11/2013
Note: Revision 4 dated 11-18-13.
PLUM COMPLETE 12/11/2013 12/11/2013
Note: Revision 4 dated 11-18-13.
FI1 HOLD 12/10/2013 12/11/2013
Note: 1. According to the manufacturers specifications, Flame control No 20-20a (under new surfaces) states that No 20-20a will not give a fire resistive rating on metal surfaces. 2. The primer must also be compatible with the fire retardant. 2010 FBC 709.4.1.1
BLD HOLD 11/19/2013 11/21/2013
Note: Provide detailed scope of the revision and identified detail of affected area detail will need to be suitable for review, construction and inspection. as per our meeting and FBC 107.2.1
BLD COMPLETE 11/14/2013 11/14/2013
Note: Released By: JMCGOWEN revision, letter from D.P.O.R. on stud spacing
BLD COMPLETE 11/14/2013 11/15/2013
Note: Released By: JMCGOWEN Truss repair
BLD HOLD 11/08/2013 11/08/2013
Note: Held By: JHINDMAN 1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1.
BLD HOLD 11/08/2013 11/08/2013
Note: Held By: JHINDMAN 1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1.
BLD HOLD 11/06/2013 11/06/2013
Note: Held By: JHINDMAN 1. Provide clarification for the uplift value and the number of screws and that are required per stud to plate connection. 2010 FBC 107.2.1
UD1 COMPLETE 10/16/2013 10/17/2013
PLUM COMPLETE 10/16/2013 10/17/2013
Note: Revision - revised underground sanitary/domestic water plumbing plans
UD1 HOLD 10/10/2013 10/11/2013
Note: Each unit will require an individual water service and meter.
PLUM HOLD 10/10/2013 10/11/2013
Note: 1. Provide sanitary riser diagram as shown on Sheet AP4.1 to match with submitted revised plumbing plans per 2010 FBC 107.2.1. 2. Verify the Building Type of plan title for clarification per 2010 FBC 107.2.1.
BLD COMPLETE 09/30/2013 09/30/2013
BLD HOLD 09/23/2013 09/24/2013
Note: 1. Provide signed and sealed drawings per 2010 FBC 107.1.
BLD COMPLETE 08/22/2013 08/22/2013
BLD HOLD 08/07/2013 08/07/2013
Note: 1. Provide roof truss engineering for review per 2010 FBC 107.3.5.
UD1 COMPLETE 08/07/2013 08/08/2013
ZON COMPLETE 08/07/2013 08/08/2013
PLLA COMPLETE 07/16/2013 07/16/2013
Note: Released By: WBUTLER
BLD HOLD 07/08/2013 07/09/2013
Note: 1. Provide roof truss engineering per 2010 FBR 107.3.5.
ENGIN1 COMPLETE 07/08/2013 07/09/2013
FI1 COMPLETE 07/08/2013 07/09/2013
MECH COMPLETE 07/08/2013 07/08/2013
PLLA HOLD 07/08/2013 07/08/2013
Note: Permit # 2013050276 Reviewer: Bill Butler, Landscape Architect 7-8-13 1. Need landscape and irrigation plans to be submitted for review and approval.
PLUM COMPLETE 07/08/2013 07/08/2013
UD1 HOLD 07/08/2013 07/15/2013
Note: Plans show single water service in to building. Each unit shall have individual service and meter located in green space outside of building in existing utility easement
BLD HOLD 05/10/2013 05/13/2013
Note: Held By: FREODICA 1. Provide specific plans and details applicable to this permit application per 2010 FBC 107.2.1.
ELEC COMPLETE 05/10/2013 07/08/2013
UD1 COMPLETE 05/10/2013 05/10/2013
ZON HOLD 05/10/2013 07/15/2013
Note: 1. On Sheet AA0.2, the gross square feet is stated as 3786 square feet. Adding up the provided Living area and Non A/C area, the total appears to be 3784 square feet. Please revise the table to reflect the correct area. 2. On Sheet AA2.1a, the table showing Gross Area lists the Non A/C area as 309 square feet; however, on Sheet AA0.2, the Non A/C area adds up to 307 square feet. Please revise the numbers as needed to consistently show the correct Gross and Non-A/C areas. 3. Please revise Sheet AA6.1 to to include the length and width dimensions of the buildings, which should match the previously approved elevations in the Development Order approval. 4. Please revise the plans to provide a screen porch elevation detailing the materials to be used on the screen enclosure, including any kickplates if applicable. 5. Per LDC Sec. 12.03.01.H and I, street address signs or building occupant signs affixed to the wall shall not exceed 2 square feet in sign copy area. Please revise the plans to include a detail of the "Brookhaven" occupant or street address wall sign to show the dimensions, not to exceed 2 square feet. 6. On Sheet AA6.1, please clarify whether the "B" located in or on the window in the dormer is a decal, a separate sign or part of the glass itself (i.e. stained glass).

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/16/2014
REINSPECTION FEE ¤40.00 04/16/2014
REINSPECTION FEE ¤40.00 04/16/2014
REINSPECTION FEE ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
REVISION ¤40.00 04/16/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤623.97 04/16/2014
IMPACT FEE PARKS ¤4,031.94 04/16/2014
IMPACT FEE SCHOOL ¤2,793.00 04/16/2014
IMPACT FEE TRANSPORTATION ¤8,146.80 04/16/2014
INSPECTION FEE 20 ¤20.00 04/16/2014
MECHANICAL FEE ¤288.60 09/27/2013
PERMIT FEE ¤2,095.50 09/27/2013
PLAN CHECK FEE ¤438.15 09/27/2013
PLUMBING FEE ¤288.60 09/27/2013
FIRE PLANS REVIEW ¤37.84 09/27/2013
ADMIN COMMERCIAL ¤60.00 09/27/2013
ELECTRIC FEE ¤288.60 09/27/2013
SURCHARGE FS 533.721 ¤51.89 09/27/2013
SURCHARGE - FS 468.631 ¤51.89 09/27/2013
Fees Total Due: ¤0.00 Total Paid: ¤20,056.78