I want to search for...

Permit #2013050245

Permit Details

Status: COED

Parcel Id: 08-12-31-5835-00000-0010
CONDITIONED SPACE: 2240 sqft
CONDITIONED SPACE: 2984 sqft
GARAGE: 996 sqft
OPENED PORCH (WITH ROOF) : 440 sqft
Total Square Footage: 6660 sqft
Block: 00000
Subdivision: 2117 - Town Center Phase III, BROOKHAVEN
Job Phone: 407-741-8500
Location Address: 171 BROOKHAVEN CT S
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 10/11/2013
NOC: RECORDED
Applicant name: SCOTT W CULP
Owner: BROOKHAVEN DEVELOPMENT LAND LTD

Address

200 E CANTON AVE # 102

WINTER PARK, FL 32789

Lot: 0010
Contracted Stated Job Value: ¤310,085.00
Job Description: BUILDING 9 - BROOKHAVEN 4 UNIT APARTMENT
Type: CN

Contractor

CPG CONSTRUCTION LLP
Status Location Address State License Number Phone Fax
CANCEL

200 E CANTON AVE # 102

WINTER PARK, FL 32789

CGC1512998 (Exp: 08/31/2016) 407-741-8500 407-643-2551

Sub Contractors

RANCE F BORDERICK
Status Location Address State License Number Phone Fax
ACTIVE

430 WEST DRIVE

ALTAMONTE SPRINGS, FL 32714

EC0000981 (Exp: 08/31/2026) (407)788-3500 407-788-2007
DAVID A CROSON
Status Location Address State License Number Phone Fax
CANCEL

31550 COUNTY ROAD 437

SORRENTO, FL 32776

CFC1426109 (Exp: 08/31/2022) 352-729-7100 352-735-0623
JOSEPH RICHARD CASSIDY JR
Status Location Address State License Number Phone Fax
CANCEL

17304 PHIL C PETERS RD

WINTER GARDEN, FL 34787

CCC1327385 (Exp: 08/31/2020) 407-654-4426 (407)654-4307
JOHN MAXEN BARTKOVICH
Status Location Address State License Number Phone
ACTIVE

818 SHADOWMOSS DR

WINTERGARDEN, FL 32787

CAC1815793 (Exp: 08/31/2026) 407-886-3729

Inspection History

Type Request Date Result Inspector
PLUMBING 1ST ROUGH 05/01/2014 APPROVED RMARVEL
Note: looked at plumbing under previous superintendant.
FIRE FINAL 04/29/2014 APPROVED JHINDMAN
LDSC- LANDSCAPE FINAL 04/29/2014 APPROVED - AS NOTED WBUTLER
Note: LANDSCAPE/ IRRIGATION FINALS FOR BROOKHAVEN BUILDINGS 24 and 25 Permit number 2013050245 (building 9) Permit number 2013050246 (building 10) 4-29-14 General Comments: 1. Irrigation control wire problem with all areas in the Brookhaven development. Need to manually bleed on all valves periodically to insure plants, trees and sod does not die. Need to resolve this before the last unit gets its final inspection approval. 2. As-builts needed from project landscape architect before last unit gets final inspection approval. 3. Stake all podocarpus that are leaning as this is a City requirement for a Florida Number one or better quality plant (plant must stand upright without staking to be a number 1) Staff is willing in this case to allow staking of those that do not stand erect. Building 9: 1. West side of building has a fire line blow off that has dug a hole and displaced mulch from the planting bed. Need to fill hole, put a splash block there and restore the mulch. 2. Replant one ligustrum at the southwest corner of the building that is blocking a downspout. 3. Check sizes of ligustrum shrubs that screen the air conditioner units and replace if they are not the required 20 inch tall. 4. Magnolia tree to the east of the building by the Fire protection line is not the required 3-1/2 inch caliper and 12 foot minimum height. Replace any other magnolia that does not meet this specification. Note, caliper may be approved at 3-1/4 inch, but not an eighth smaller. Building 10: 1. Need one more ligustrum by the west side of the building to close the gap by the electric meter. 2. Fix the disturbed mulch area at the southwest corner of the building where a plumber had been digging. 3. Graded smooth and sod with Bahia sod the disturbed area in the natural area to the rear of the center of the building going to the irrigation gate valve. If sod cannot be placed by today, need to install a silt fence to prevent erosion from the impending rain forecast for tonight. Another bare soil area exists west of this and need to sod that as well. 4. Remove and cap the small rotor head at the southwest corner of the building that is not needed and not on the plans. STILL OUTSTANDING COMMENTS FOR BUILDINGS 25 AND 24 Building 25: 1. Replace broken concrete water meter box on the west side of parking lot entrance. Building 24 1. Need to excavate around water meter boxes where dirt has sunk out and put filter cloth over the openings where dirt is entering boxes. Fill voids around box and replace sod. 2. Need to re-grade the rear of the building so the water drains positively away from the building. Re-sod any disturbed area. Building perimeter floods when irrigation is on or it rains. 3. Remove the porta-potty from the cul-de-sac area. STILL OUTSTANDING COMMENTS FOR BUILDINGS 26 and 27: 1. The parking lot was modified to use environmental curbing instead of 6 inch highback curb. Additionally add two parking stops on each side of the parking lot along the northern edge of the two northernmost parking spaces that are adjacent to the landscape islands to prevent cars from entering the islands. STILL NOT COMPLETE- CURBING OF PARKING LOT ISLANDS IS REQUIRED PER SECTION 11.03.04.B.3.a. of the Land Development Code. The modification to the parking lot was not previously approved by the City. Previous plan showed these islands curbed.
U - UTILITY COMMERCIAL FINAL 04/29/2014 FINAL APPROVED DSPENCER
FIRE FINAL 04/28/2014 CANCELLED BY APPLICANT JHINDMAN
BUILDING FINAL 04/28/2014 APPROVED BBEMBRY
PLUMBING FINAL 04/28/2014 APPROVED JHINDMAN
HVAC FINAL 04/28/2014 APPROVED JHINDMAN
ELECTRIC FINAL 04/28/2014 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 04/15/2014 APPROVED RMARVEL
GRAVITY SEWER 03/26/2014 APPROVED JHINDMAN
U - SEWER TIE IN 03/25/2014 APPROVED KKING
LATH/BRICK/WATER BARRIER 02/27/2014 APPROVED DROCKWELL
FIREWALL 02/24/2014 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
INSULATION 02/24/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 02/21/2014 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 2/21/2014 3:35:03 PM NOT READY J.HINDMAN 986-3784. 2010 FBC 110.3.
FIREWALL 02/20/2014 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 2/20/2014 3:22:19 PM PENETRATIONS
ALL ROUGH 02/20/2014 APPROVED JHINDMAN
ELECTRIC 1ST ROUGH 02/20/2014 APPROVED JHINDMAN
Note: Inspection Resulted at 2/20/2014 3:22:20 PM UNDERGROUND SERVICE CONDUIT
FIREWALL 02/10/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 2/10/2014 3:28:59 PM SOFFIT NOT COMPLETE AND PORCH AREAS NOT COMPOUNDED FULLY
FIREWALL 02/06/2014 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 2/6/2014 2:32:08 PM SCREWS IN CHASEWALL
EXTERIOR STRAP/CLIP 02/03/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
EXTERIOR WALL SHEATHING / SHEARWALL 02/03/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACE / TIE DOWN 02/03/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
EXTERIOR STRAP/CLIP 01/31/2014 CANCELLED BY APPLICANT DROCKWELL
ROOF SHEATHING / BRACE / TIE DOWN 01/31/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 1/31/2014 12:34:46 PM NOT READY FOR INSPECTION
EXTERIOR WALL SHEATHING / SHEARWALL 01/31/2014 CANCELLED BY APPLICANT DROCKWELL
FIREWALL 01/13/2014 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 1/13/2014 1:23:33 PM TAPING IN ATTIC
FIREWALL 01/10/2014 PARTIALLY APPROVED JHINDMAN
Note: Inspection Resulted at 1/10/2014 2:24:05 PM SCREWS IN ATTIC
ELECTRIC TEMP POLE 11/12/2013 APPROVED CMINI
Note: Inspection Resulted at 11/12/2013 3:30:39 PM CALLED FPL TO RELEASE POWER AT 3:00,SPOKE WITH EMILY
ELECTRIC 1ST ROUGH 11/07/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 11/07/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ELECTRIC 1ST ROUGH 11/05/2013 CANCELLED BY APPLICANT CMINI
MONOLITHIC SLAB 11/05/2013 CANCELLED BY APPLICANT CMINI

Review History

Department Status Date In Date Out
BLD COMPLETE 02/10/2014 02/10/2014
Note: Revisions 5 and 6.
ELEC COMPLETE 02/10/2014 02/10/2014
FI1 COMPLETE 02/10/2014 02/10/2014
PLUM COMPLETE 02/10/2014 02/10/2014
Note: Revision - Changed sanitary riser diagram, sheet P3.3b, rev. 5.
BLD COMPLETE 12/30/2013 12/31/2013
FI1 COMPLETE 12/30/2013 12/30/2013
Note: Released By: JHINDMAN
ELEC COMPLETE 12/11/2013 12/12/2013
FI1 HOLD 12/11/2013 12/12/2013
Note: . According to the manufacturers specifications, Flame control No 20-20a (under new surfaces) states that No 20-20a will not give a fire resistive rating on metal surfaces. 2. The primer must also be compatible with the fire retardant. 2010 FBC 709.4.1.1
MECH COMPLETE 12/11/2013 12/12/2013
Note: Revision 4 dated 11-18-13.
PLUM COMPLETE 12/11/2013 12/12/2013
Note: Revision 4 dated 11-18-13.
BLD COMPLETE 11/19/2013 12/12/2013
BLD COMPLETE 11/14/2013 11/14/2013
Note: Released By: JMCGOWEN revision, letter from D.P.O.R. on stud spacing
BLD HOLD 11/14/2013 11/15/2013
Note: Divide plans into building types that corresponds with the associate permits FBC 107.2.1
BLD HOLD 11/08/2013 11/08/2013
Note: Held By: JHINDMAN 1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1.
BLD HOLD 11/08/2013 11/08/2013
Note: Held By: JHINDMAN 1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1.
BLD HOLD 11/06/2013 11/06/2013
Note: Held By: JHINDMAN 1. Provide clarification for the uplift value and the number of screws and that are required per stud to plate connection. 2010 FBC 107.2.1
BLD COMPLETE 09/30/2013 09/30/2013
BLD HOLD 09/23/2013 09/24/2013
Note: 1. Provide signed and sealed drawings per 2010 FBC 107.1.
BLD COMPLETE 08/22/2013 08/22/2013
FI1 COMPLETE 08/22/2013 08/22/2013
ZON COMPLETE 08/22/2013 08/22/2013
FI1 HOLD 08/08/2013 08/08/2013
Note: Provide a Maltese Cross with a RF designation per 2010 F.A.C. 69 A.
BLD HOLD 08/08/2013 08/08/2013
Note: Provide roof and floor truss engineering per 2010 FBC 107.3.5.
ZON HOLD 08/08/2013 08/08/2013
Note: 1. Although the Area and Height Limitation table on Sheet A1.0 was revised, it appears that the area called out (3,687 square feet) only represents the 1st floor of the building, inclusive of the riser closet and tenant separation space. Please revise the table to reflect the total building area of 6,671 square feet. 2. The revised sheet A6.4 shows that the side elevation dimension is 51 ft-6 in. from the front face of the garages to the outer limit of the column at the rear patio. The color elevations approved with the Development Order show that same dimension at 51 ft-2 in. Please revise the plans so that the dimension matches the approved color elevations incorporated into the Development Order. As an alternative, a modification can be made to the Development Order by submitting a new color elevation with the corrected dimension consistent with the dimension shown on the elevations in the Building Permit set.
BLD HOLD 07/09/2013 07/10/2013
Note: 1. Provide roof and floor truss engineering per 2010 FBC 107.3.5.
ENGIN1 COMPLETE 07/09/2013 07/16/2013
FI1 HOLD 07/09/2013 07/10/2013
Note: 1. Provide a Maltese Cross with a FR designation per F. A. C. 69 A.
MECH COMPLETE 07/09/2013 07/10/2013
PLLA COMPLETE 07/09/2013 07/10/2013
PLUM COMPLETE 07/09/2013 07/10/2013
UD1 COMPLETE 07/09/2013 07/15/2013
BLD HOLD 05/10/2013 05/13/2013
Note: Held By: FREODICA 1. Provide specific plans and details applicable to this permit application per 2010 FBC 107.2.1.
ELEC COMPLETE 05/10/2013 07/10/2013
ZON HOLD 05/10/2013 07/16/2013
Note: 1. On Sheet A0.2a, there are inconsistencies in the building area data when the two provided tables are compared to each other. One table states that the 1st floor A/C area per unit is 560 SF, and the 1st floor non-A/C area (garage and porches) is 359 SF for a total of 919 SF of Non-A/C area. 919 SF x 4 units is 3676 SF, but the second table shows 3687 SF gross. Also, the total gross area per unit on one table is 1665 SF and 1665 SF x 4 units is 6660 SF, but the second table GSF is stated as 6671 SF. Please revise the data tables so that the building areas expressed on them are consistent with each other. 2. On Sheet A1.0, the Area and Height Limitation Table makes references to the 1-Story Villa buildings. Please revise the table so that all references and data correspond to the Townhouse style buildings. 3. On Sheet A1.0, the reference plan or key plan showing the building locations incorrectly labels Building 15 as a “CCCCCC” type building and the callout is “greyed” out. Please revise to show Building 15 as a “CCCC” type building and show the callout in black. 4. Please revise the TH-4 Area Calculations on Sheets A2.4a and A2.4b to be consistent with the area calculations (once revised) found on Sheet A0.2a. The Non-A/C area found on sheet A0.2a is stated as 359 SF, and 359 SF x 4 units is 1436 SF, not 1447 SF. Also, the total GSF appears to be 6660 SF. 5. Please revise the plans to state that all metal roof fasteners must be color matched to the roof panels. 6. Please revise the plans to provide screen porch elevations detailing the materials to be used on the screen enclosures, including any kickplates if applicable. 7. Please revise sheet A6.4 to include the length and width dimensions of the buildings, which should match the previously approved elevations in the Development Order approval.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/01/2014
REINSPECTION FEE ¤40.00 05/01/2014
REINSPECTION FEE ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
REVISION ¤40.00 05/01/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤831.96 05/01/2014
IMPACT FEE SCHOOL ¤3,724.00 05/01/2014
IMPACT FEE TRANSPORTATION ¤10,862.40 05/01/2014
INSPECTION FEE 20 ¤20.00 05/01/2014
PARKS IMPACT FEE ¤3,576.96 05/01/2014
ADDITIONAL FEE ¤200.00 02/21/2014
ADMIN COMMERCIAL ¤60.00 10/11/2013
ELECTRIC FEE ¤426.60 10/11/2013
FIRE PLANS REVIEW ¤66.60 10/11/2013
MECHANICAL FEE ¤426.60 10/11/2013
PERMIT FEE ¤3,360.50 10/11/2013
PLAN CHECK FEE ¤702.65 10/11/2013
PLUMBING FEE ¤426.60 10/11/2013
SURCHARGE FS 533.721 ¤81.05 10/11/2013
SURCHARGE - FS 468.631 ¤81.05 10/11/2013
Fees Total Due: ¤0.00 Total Paid: ¤25,526.97