Permit #2013050274

Permit Details

Status: COED

Parcel Id: 08-12-31-5835-00000-0010
CONDITIONED SPACE: 2800 sqft
CONDITIONED SPACE: 3730 sqft
GARAGE: 1245 sqft
OPENED PORCH (WITH ROOF) : 550 sqft
Total Square Footage: 8325 sqft
Block: 00000
Subdivision: 2117 - Town Center Phase III, BROOKHAVEN
Job Phone: 407-741-8500
Location Address: 136 BROOKHAVEN CT S
Type: BM - BUILDING MULTI - APARTMENT
Issue Date: 09/13/2013
NOC: RECORDED
Applicant name: SCOTT W CULP
Owner: BROOKHAVEN DEVELOPMENT LAND LTD

Address

200 E CANTON AVE # 102

WINTER PARK, FL 32789

Lot: 0010
Contracted Stated Job Value: ¤387,719.00
Job Description: BUILDING 18 - BROOKHAVEN 5 UNIT APARTMENT
Type: CN

Contractor

CPG CONSTRUCTION LLP
Status Location Address State License Number Phone Fax
CANCEL

200 E CANTON AVE # 102

WINTER PARK, FL 32789

CGC1512998 (Exp: 08/31/2016) 407-741-8500 407-643-2551

Sub Contractors

RANCE F BORDERICK
Status Location Address State License Number Phone Fax
ACTIVE

430 WEST DRIVE

ALTAMONTE SPRINGS, FL 32714

EC0000981 (Exp: 08/31/2026) (407)788-3500 407-788-2007
DAVID A CROSON
Status Location Address State License Number Phone Fax
CANCEL

31550 COUNTY ROAD 437

SORRENTO, FL 32776

CFC1426109 (Exp: 08/31/2022) 352-729-7100 352-735-0623
JOSEPH RICHARD CASSIDY JR
Status Location Address State License Number Phone Fax
CANCEL

17304 PHIL C PETERS RD

WINTER GARDEN, FL 34787

CCC1327385 (Exp: 08/31/2020) 407-654-4426 (407)654-4307
JOHN MAXEN BARTKOVICH
Status Location Address State License Number Phone
ACTIVE

818 SHADOWMOSS DR

WINTERGARDEN, FL 32787

CAC1815793 (Exp: 08/31/2026) 407-886-3729

Inspection History

Type Request Date Result Inspector
LDSC- LANDSCAPE FINAL 04/01/2014 APPROVED CJMINI
Note: THIS IS A REINSPECTION
U - UTILITY COMMERCIAL FINAL 03/31/2014 FINAL APPROVED DSPENCER
LDSC- LANDSCAPE FINAL 03/31/2014 Disapproved -FEE REQUIRED CJMINI
Note: Replace the corner Crape Myrtle to correct specs. Add Splash Block to all block to down spouts. Relocate two spray heads on side rear area off building corner. Replace two undersized V. S. Six Oleanders on building 18 and two on building 19 next week when next stock arrives.
FIRE FINAL 03/27/2014 APPROVED JHINDMAN
BUILDING FINAL 03/27/2014 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
BUILDING FINAL 03/26/2014 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 3/26/2014 1:17:47 PM HANDRAILS AT STAISR ARE MISSING 2010 FBC 110.5.
PLUMBING FINAL 03/26/2014 APPROVED JHINDMAN
HVAC FINAL 03/26/2014 APPROVED JHINDMAN
ELECTRIC FINAL 03/26/2014 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 03/12/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 3/12/2014 2:53:40 PM CALLED FPL AT 9:37
ELECTRIC - EARLY POWER 03/11/2014 CANCELLED BY APPLICANT RMARVEL
GRAVITY SEWER 03/10/2014 APPROVED RMARVEL
U - SEWER TIE IN 03/10/2014 APPROVED DSPENCER
ELECTRIC 1ST ROUGH 02/05/2014 APPROVED JHINDMAN
Note: Inspection Resulted at 2/5/2014 12:54:38 PM UNDERGROUND SERVICE PIPING
LATH/BRICK/WATER BARRIER 02/04/2014 APPROVED JHINDMAN
FIREWALL 02/04/2014 APPROVED JHINDMAN
INSULATION 01/31/2014 APPROVED JHINDMAN
FIREWALL 01/29/2014 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ALL ROUGH 01/29/2014 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ALL ROUGH 01/28/2014 Disapproved -FEE REQUIRED JHINDMAN
Note: Inspection Resulted at 1/28/2014 3:20:59 PM MECHANICAL IS NOT COMPLETE, SQUASHED DUCTS, CONDENSATE IS NOT COMPLETE, BOOTS MISSING.2010 FBC 110.4. 2. PROVIDE PENETRATION DETAIL FOR THE UL SYSTEM. 2010 FBC 110.4
FIREWALL 01/28/2014 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 1/28/2014 3:20:58 PM FIRE RETARDANT SPRAY MISSING IN ATTIC
FIREWALL 01/21/2014 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 1/21/2014 12:44:33 PM TAPING IN ATTIC
FIREWALL 01/17/2014 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 1/17/2014 11:58:42 AM TAPING IN ATTIC
ROOF SHEATHING / BRACE / TIE DOWN 01/13/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
EXTERIOR STRAP/CLIP 01/13/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
EXTERIOR WALL SHEATHING / SHEARWALL 01/13/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
EXTERIOR WALL SHEATHING / SHEARWALL 01/10/2014 CANCELLED BY APPLICANT JHINDMAN
ROOF SHEATHING / BRACE / TIE DOWN 01/10/2014 CANCELLED BY APPLICANT RMARVEL
Note: THIS IS A REINSPECTION
EXTERIOR STRAP/CLIP 01/10/2014 CANCELLED BY APPLICANT RMARVEL
FIREWALL 01/10/2014 PARTIALLY APPROVED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 1/10/2014 2:24:06 PM TAPING IN ATTIC
FIREWALL 01/08/2014 PARTIALLY APPROVED JHINDMAN
Note: Inspection Resulted at 1/8/2014 1:53:56 PM SCREWS
ROOF SHEATHING / BRACE / TIE DOWN 12/27/2013 CANCELLED BY APPLICANT CMINI
ELECTRIC TEMP POLE 10/22/2013 APPROVED RMARVEL
Note: Inspection Resulted at 10/22/2013 2:34:18 PM CALLED FPL AT 9:35
ELECTRIC 1ST ROUGH 10/03/2013 APPROVED RMARVEL
Note: Inspection Resulted at 10/3/2013 3:43:51 PM UFER GROUND. 20FT CONCRETE ENCASED ELECTRODE.
MONOLITHIC SLAB 10/03/2013 APPROVED RMARVEL
PLUMBING 1ST ROUGH 09/27/2013 APPROVED CMINI

Review History

Department Status Date In Date Out
BLD COMPLETE 02/07/2014 02/07/2014
FI1 COMPLETE 02/07/2014 02/07/2014
BLD COMPLETE 01/22/2014 01/22/2014
ELEC COMPLETE 01/22/2014 01/23/2014
PLUM COMPLETE 01/22/2014 01/23/2014
FI1 COMPLETE 12/30/2013 12/30/2013
Note: Released By: JHINDMAN
BLD COMPLETE 12/18/2013 12/18/2013
BLD COMPLETE 12/11/2013 12/12/2013
ELEC COMPLETE 12/11/2013 12/12/2013
FI1 HOLD 12/11/2013 12/12/2013
Note: . According to the manufacturers specifications, Flame control No 20-20a (under new surfaces) states that No 20-20a will not give a fire resistive rating on metal surfaces. 2. The primer must also be compatible with the fire retardant. 2010 FBC 709.4.1.1
MECH COMPLETE 12/11/2013 12/13/2013
Note: Revision 4 dated 11-18-13.
PLUM COMPLETE 12/11/2013 12/13/2013
Note: Revision 4 dated 11-18-13.
BLD HOLD 11/24/2013 12/03/2013
Note: Provide detailed scope of the revision and identified detail of affected area detail will need to be suitable for review, construction and inspection. as per our meeting and FBC 107.2.1
BLD HOLD 11/19/2013 11/21/2013
Note: Provide detailed scope of the revision and identified detail of affected area detail will need to be suitable for review, construction and inspection. as per our meeting and FBC 107.2.1
BLD COMPLETE 11/14/2013 11/14/2013
Note: Released By: JMCGOWEN revision, letter from D.P.O.R. on stud spacing
BLD HOLD 11/14/2013 11/15/2013
Note: Divide plans into building types that corresponds with the associate permits FBC 107.2.1
BLD HOLD 11/08/2013 11/08/2013
Note: Held By: JHINDMAN 1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1.
BLD HOLD 11/08/2013 11/08/2013
Note: Held By: JHINDMAN 1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1.
BLD HOLD 11/06/2013 11/06/2013
Note: Held By: JHINDMAN 1. Provide clarification for the uplift value and the number of screws and that are required per stud to plate connection. 2010 FBC 107.2.1
BLD COMPLETE 09/30/2013 09/30/2013
BLD HOLD 09/23/2013 09/24/2013
Note: 1. Provide signed and sealed drawings per 2010 FBC 107.1.
BLD COMPLETE 08/22/2013 08/22/2013
FI1 COMPLETE 08/22/2013 08/22/2013
ZON COMPLETE 08/22/2013 08/22/2013
FI1 HOLD 08/09/2013 08/09/2013
Note: Provide a Maltese Cross with a RF designation per F.A.C. 69A.
BLD HOLD 08/09/2013 08/09/2013
Note: Provide roof and floor truss engineering per 2010 FBC 107.3.5.
ZON HOLD 08/09/2013 08/12/2013
Note: 1. Although the Area and Height Limitation table on Sheet A1.0 was revised, it appears that the area called out (4,611 square feet) only represents the 1st floor of the building, inclusive of the riser closet and tenant separation space. Please revise the table to reflect the total building area of 8,341 square feet. 2. The revised sheet A6.5 shows that the side elevation dimension is 51 ft-6 in. from the front face of the garages to the outer limit of the column at the rear patio. The color elevations approved with the Development Order show that same dimension at 51 ft-2 in. Please revise the plans so that the dimension matches the approved color elevations incorporated into the Development Order. As an alternative, a modification can be made to the Development Order by submitting a new color elevation with the corrected dimension consistent with the dimension shown on the elevations in the Building Permit set.
PLLA COMPLETE 07/16/2013 07/16/2013
Note: Released By: WBUTLER
BLD HOLD 07/08/2013 07/09/2013
Note: 1. Provide roof and floor truss engineering per 2010 FBC 107.3.5.
ELEC COMPLETE 07/08/2013 07/09/2013
ENGIN1 COMPLETE 07/08/2013 07/09/2013
FI1 HOLD 07/08/2013 07/09/2013
Note: 1. Provide a Maltese Cross with a RF designation per F.A.C. 69A.
MECH COMPLETE 07/08/2013 07/09/2013
PLLA HOLD 07/08/2013 07/09/2013
Note: Reviewer: Bill Butler, Landscape Architect 7-9-13 1. Landscape and irrigation plans must be submitted for review and approval.
PLUM COMPLETE 07/08/2013 07/09/2013
UD1 COMPLETE 07/08/2013 07/15/2013
ZON HOLD 07/08/2013 07/15/2013
Note: 1. On Sheet A0.2a, there are inconsistencies in the building area data when the two provided tables are compared to each other. One table states that the 1st floor A/C area per unit is 560 SF, and the 1st floor non-A/C area (garage and porches) is 359 SF for a total of 919 SF of Non-A/C area. 919 SF x 5 units is 4595 SF, but the Gross Square feet called out on another table is 4611 SF. Additionally, the 2nd Floor A/C area per unit is 746 square feet per unit on one table. 746 SF x 5 units is 3730 SF, while table showing gross square feet calcs calls out 3235 SF of Living Area. Finally, the total gross area per unit on one table is 1665 SF x 5 units is 8325 SF, but the second table shows the total GSF is 8343 SF. Please revise the data tables so that all building areas expressed on them are consistent with each other. 2. On Sheet A1.0, the Area and Height Limitation Table makes references to the 1-Story Villa buildings. Please revise the table so that all references and data correspond to the Townhouse style buildings. 3. Please revise Sheet A2.5a and A2.5b to show TH-5 Area Calculations. The current sheet shows TH-4 Area Calculations. 4. Please revise the plans to state that all metal roof fasteners must be color matched to the roof panels. 5. Please revise the plans to provide screen porch elevations detailing the materials to be used on the screen enclosures, including any kickplates if applicable. 6. Please revise sheet A6.5 to include the length and width dimensions of the buildings, which should match the previously approved elevations in the Development Order approval.
BLD HOLD 05/10/2013 05/21/2013
Note: Held By: JMCGOWEN Held By: FREODICA 1. Provide specific plans and details applicable to this permit application per 2010 FBC 107.2.1.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/01/2014
REINSPECTION FEE ¤40.00 04/01/2014
REINSPECTION FEE ¤40.00 04/01/2014
REINSPECTION FEE ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤1,039.95 04/01/2014
IMPACT FEE PARKS ¤6,719.90 04/01/2014
IMPACT FEE SCHOOL ¤4,655.00 04/01/2014
IMPACT FEE TRANSPORTATION ¤13,578.00 04/01/2014
INSPECTION FEE 20 ¤20.00 04/01/2014
MECHANICAL FEE ¤518.40 09/13/2013
PERMIT FEE ¤4,202.00 09/13/2013
PLAN CHECK FEE ¤878.60 09/13/2013
PLUMBING FEE ¤518.40 09/13/2013
FIRE PLANS REVIEW ¤83.25 09/13/2013
ADMIN COMMERCIAL ¤60.00 09/13/2013
ELECTRIC FEE ¤518.40 09/13/2013
SURCHARGE FS 533.721 ¤100.44 09/13/2013
SURCHARGE - FS 468.631 ¤100.44 09/13/2013
Fees Total Due: ¤0.00 Total Paid: ¤33,712.78