I want to search for...
Permit #2013050275
Permit Details
Status: COED
| Parcel Id: 08-12-31-5835-00000-0010 |
| CONDITIONED SPACE: 2800 sqft |
| CONDITIONED SPACE: 3730 sqft |
| OPENED PORCH (WITH ROOF) : 550 sqft |
| GARAGE: 1245 sqft |
| Total Square Footage: 8325 sqft |
| Block: 00000 |
| Subdivision: 2117 - Town Center Phase III, BROOKHAVEN |
| Job Phone: 407-741-8500 |
| Location Address: 120 BROOKHAVEN CT S |
| Type: BM - BUILDING MULTI - APARTMENT |
| Issue Date: 09/13/2013 |
| NOC: RECORDED |
| Applicant name: SCOTT W CULP |
| Owner: BROOKHAVEN DEVELOPMENT LAND LTD |
|
Address 200 E CANTON AVE # 102 WINTER PARK, FL 32789 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤387,719.00 |
| Job Description: BUILDING 19 - BROOKHAVEN 5 UNIT APARTMENT |
| Type: CN |
Contractor
CPG CONSTRUCTION LLP
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
200 E CANTON AVE # 102 WINTER PARK, FL 32789 |
CGC1512998 (Exp: 08/31/2016) | 407-741-8500 | 407-643-2551 |
Sub Contractors
RANCE F BORDERICK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
430 WEST DRIVE ALTAMONTE SPRINGS, FL 32714 |
EC0000981 (Exp: 08/31/2026) | (407)788-3500 | 407-788-2007 |
DAVID A CROSON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
31550 COUNTY ROAD 437 SORRENTO, FL 32776 |
CFC1426109 (Exp: 08/31/2022) | 352-729-7100 | 352-735-0623 |
JOSEPH RICHARD CASSIDY JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17304 PHIL C PETERS RD WINTER GARDEN, FL 34787 |
CCC1327385 (Exp: 08/31/2020) | 407-654-4426 | (407)654-4307 |
JOHN MAXEN BARTKOVICH
| Status | Location Address | State License Number | Phone |
| ACTIVE |
818 SHADOWMOSS DR WINTERGARDEN, FL 32787 |
CAC1815793 (Exp: 08/31/2026) | 407-886-3729 |
Inspection History
| Type | Request Date | Result | Inspector |
| LDSC- LANDSCAPE FINAL | 04/01/2014 | APPROVED | CJMINI |
| Note: THIS IS A REINSPECTION | |||
| U - UTILITY COMMERCIAL FINAL | 03/31/2014 | FINAL APPROVED | DSPENCER |
| LDSC- LANDSCAPE FINAL | 03/31/2014 | Disapproved -FEE REQUIRED | CJMINI |
| Note: Replace small river birch tree in rear with a Florida Grade Number One multi trunk to add up to four inches. Add splash boxes to down spouts. Add podocarpus to front horseshoe shaped bed just outside entrance way. Add mondo grass to small interior squares next to downspouts. Re adjust irrigation heads in small median strip next to road and sidewalk to reduce overspray. | |||
| FIRE FINAL | 03/27/2014 | APPROVED | JHINDMAN |
| BUILDING FINAL | 03/27/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| BUILDING FINAL | 03/26/2014 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 3/26/2014 1:17:48 PM HANDRAILS AT STAIRS ARE MISSING 2010 FBC 110.5. | |||
| PLUMBING FINAL | 03/26/2014 | APPROVED | JHINDMAN |
| HVAC FINAL | 03/26/2014 | APPROVED | JHINDMAN |
| ELECTRIC FINAL | 03/26/2014 | APPROVED | JHINDMAN |
| ELECTRIC - EARLY POWER | 03/12/2014 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 3/12/2014 2:53:41 PM CALLED FPL AT 9:37 | |||
| GRAVITY SEWER | 03/10/2014 | APPROVED | RMARVEL |
| U - SEWER TIE IN | 03/10/2014 | APPROVED | DSPENCER |
| ELECTRIC 1ST ROUGH | 02/05/2014 | APPROVED | JHINDMAN |
| Note: Inspection Resulted at 2/5/2014 12:54:39 PM UNDERGROUND SERVICE CONDUIT | |||
| LATH/BRICK/WATER BARRIER | 02/04/2014 | APPROVED | JHINDMAN |
| FIREWALL | 01/30/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIREWALL | 01/27/2014 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/27/2014 1:25:16 PM CONCEALED AREAS OK | |||
| INSULATION | 01/27/2014 | APPROVED | JHINDMAN |
| ALL ROUGH | 01/24/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION receptacle in stairways relocated to sidewall | |||
| ALL ROUGH | 01/23/2014 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 1/23/2014 3:40:35 PM 1. ELECTRICAL PANELS INSIDE ARE NOT READY.2010 FBC 110.1. 2. PROVIDE LETTER OF MODIFICATION FOR THE FRESH AIR INTAKE AND MOVING THE RECEPTACLE IN THE STAIRWAY. 2010 FBC 110.4.. OK TO INSULATE. | |||
| FIREWALL | 01/23/2014 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/23/2014 3:40:35 PM ATTIC SPRAY | |||
| FIREWALL | 01/13/2014 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/13/2014 1:23:31 PM TAPING IN ATTIC | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 01/10/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| EXTERIOR STRAP/CLIP | 01/09/2014 | APPROVED | DROCKWELL |
| EXTERIOR WALL SHEATHING / SHEARWALL | 01/09/2014 | APPROVED | DROCKWELL |
| ROOF SHEATHING / BRACE / TIE DOWN | 01/09/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/9/2014 3:27:21 PM COMPLETE TRUSS BRACING TO EXTERIOR WALLS/FIREWALLS/PROVIDE APPROVED REPAIR FOR ANCHORING 4X6 POSTS TO DRY-BOTTOM-CANNOT NAIL BOTH SIDES. | |||
| FIREWALL | 01/07/2014 | PARTIALLY APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/7/2014 12:20:12 PM MUD AND TAPE | |||
| FIREWALL | 01/06/2014 | PARTIALLY APPROVED | JHINDMAN |
| Note: Inspection Resulted at 1/6/2014 12:21:05 PM SCREWS IN ATTIC | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 12/30/2013 | CANCELLED BY APPLICANT | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 12/27/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 12/27/2013 2:42:42 PM LEDGER NEEDS TO BE NAILED INTO FLOOR TRUSSES...LOOSE SHEATHING...FRONT ENTRY NEEDS CONTINUOUS LOAD PATH...CHECK TRUSS ENGINEERING..OVERFRAMING DROP DOWN STRAP CAN NOT HAVE BEND IN IT.THREADED RODS NEED TO BE TIGHT.NEED TO SPECIFY ON PLANS THAT PARTY WALL IS TO BE A DOUBLE 2X4,FRAMING NOTES CALL FOR A 2X6 WALL..CHECK ALL NOT READY | |||
| ELECTRIC TEMP POLE | 10/17/2013 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 10/17/2013 3:43:24 PM CALLED AT 3:05 | |||
| MONOLITHIC SLAB | 10/03/2013 | APPROVED | RMARVEL |
| ELECTRIC 1ST ROUGH | 10/03/2013 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 10/3/2013 3:43:51 PM UFER GROUND. 20FT CONCRETE ENCASED ELECTRODE. | |||
| PLUMBING 1ST ROUGH | 09/23/2013 | APPROVED | RMARVEL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/07/2014 | 02/07/2014 |
| FI1 | COMPLETE | 02/07/2014 | 02/07/2014 |
| BLD | COMPLETE | 01/22/2014 | 01/23/2014 |
| ELEC | COMPLETE | 01/22/2014 | 01/23/2014 |
| PLUM | COMPLETE | 01/22/2014 | 01/23/2014 |
| FI1 | COMPLETE | 12/30/2013 | 12/30/2013 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 12/18/2013 | 12/18/2013 |
| ELEC | COMPLETE | 12/11/2013 | 12/12/2013 |
| FI1 | HOLD | 12/11/2013 | 12/12/2013 |
| Note: . According to the manufacturers specifications, Flame control No 20-20a (under new surfaces) states that No 20-20a will not give a fire resistive rating on metal surfaces. 2. The primer must also be compatible with the fire retardant. 2010 FBC 709.4.1.1 | |||
| MECH | COMPLETE | 12/11/2013 | 12/13/2013 |
| Note: Revision 4 dated 11-18-13. | |||
| PLUM | COMPLETE | 12/11/2013 | 12/13/2013 |
| Note: Revision 4 dated 11-18-13. | |||
| BLD | COMPLETE | 11/19/2013 | 12/12/2013 |
| BLD | COMPLETE | 11/14/2013 | 11/14/2013 |
| Note: Released By: JMCGOWEN revision, letter from D.P.O.R. on stud spacing | |||
| BLD | HOLD | 11/14/2013 | 11/15/2013 |
| Note: Divide plans into building types that corresponds with the associate permits FBC 107.2.1 | |||
| BLD | HOLD | 11/08/2013 | 11/08/2013 |
| Note: Held By: JHINDMAN1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1. | |||
| BLD | HOLD | 11/08/2013 | 11/08/2013 |
| Note: Held By: JHINDMAN 1. Provide a complete structural drawing for the header changes that is suitable for review, construction and inspection. 2010 FBC 107.2.1. | |||
| BLD | HOLD | 11/06/2013 | 11/06/2013 |
| Note: Held By: JHINDMAN 1. Provide clarification for the uplift value and the number of screws and that are required per stud to plate connection. 2010 FBC 107.2.1 | |||
| BLD | COMPLETE | 09/30/2013 | 09/30/2013 |
| BLD | HOLD | 09/23/2013 | 09/24/2013 |
| Note: 1. Provide signed and sealed drawings per 2010 FBC 107.1. | |||
| BLD | COMPLETE | 08/22/2013 | 08/22/2013 |
| FI1 | COMPLETE | 08/22/2013 | 08/22/2013 |
| ZON | COMPLETE | 08/22/2013 | 08/22/2013 |
| FI1 | HOLD | 08/07/2013 | 08/08/2013 |
| Note: 1. The Maltese Cross on page A0.3A does not have a R F designation per F.A.C.69A. | |||
| BLD | HOLD | 08/07/2013 | 08/08/2013 |
| Note: 1. Provide roof and floor truss engineering for review per 2010 FBC 107.3.5. | |||
| ZON | HOLD | 08/07/2013 | 08/09/2013 |
| Note: 1. Although the Area and Height Limitation table on Sheet A1.0 was revised, it appears that the area called out (4,611 square feet) only represents the 1st floor of the building, inclusive of the riser closet and tenant separation space. Please revise the table to reflect the total building area of 8,341 square feet. 2. The revised sheet A6.5 shows that the side elevation dimension is 51 ft-6 in. from the front face of the garages to the outer limit of the column at the rear patio. The color elevations approved with the Development Order show that same dimension at 51 ft-2 in. Please revise the plans so that the dimension matches the approved color elevations incorporated into the Development Order. As an alternative, a modification can be made to the Development Order by submitting a new color elevation with the corrected dimension consistent with the dimension shown on the elevations in the Building Permit set. | |||
| PLLA | COMPLETE | 07/16/2013 | 07/16/2013 |
| Note: Released By: WBUTLER | |||
| BLD | HOLD | 07/08/2013 | 07/09/2013 |
| Note: 1. Provide roof and floor truss engineering per 2010 FBC 107.3.5. | |||
| ELEC | COMPLETE | 07/08/2013 | 07/09/2013 |
| ENGIN1 | COMPLETE | 07/08/2013 | 07/09/2013 |
| FI1 | HOLD | 07/08/2013 | 07/09/2013 |
| Note: 1. Provide a Maltese Cross with a RF designation per F.A.C. 69A. | |||
| MECH | COMPLETE | 07/08/2013 | 07/09/2013 |
| PLLA | HOLD | 07/08/2013 | 07/09/2013 |
| Note: Reviewer: Bill Butler, Landscape Architect 7-9-13 1. Landscape and irrigation plans must be submitted for review and approval. | |||
| PLUM | COMPLETE | 07/08/2013 | 07/09/2013 |
| UD1 | COMPLETE | 07/08/2013 | 07/15/2013 |
| BLD | HOLD | 05/10/2013 | 05/21/2013 |
| Note: Held By: JMCGOWEN Held By: FREODICA 1. Provide specific plans and details applicable to this permit application per 2010 FBC 107.2.1. | |||
| ZON | HOLD | 05/10/2013 | 07/15/2013 |
| Note: 1. On Sheet A0.2a, there are inconsistencies in the building area data when the two provided tables are compared to each other. One table states that the 1st floor A/C area per unit is 560 SF, and the 1st floor non-A/C area (garage and porches) is 359 SF for a total of 919 SF of Non-A/C area. 919 SF x 5 units is 4595 SF, but the Gross Square feet called out on another table is 4611 SF. Additionally, the 2nd Floor A/C area per unit is 746 square feet per unit on one table. 746 SF x 5 units is 3730 SF, while table showing gross square feet calcs calls out 3235 SF of Living Area. Finally, the total gross area per unit on one table is 1665 SF x 5 units is 8325 SF, but the second table shows the total GSF is 8343 SF. Please revise the data tables so that all building areas expressed on them are consistent with each other. 2. On Sheet A1.0, the Area and Height Limitation Table makes references to the 1-Story Villa buildings. Please revise the table so that all references and data correspond to the Townhouse style buildings. 3. Please revise Sheet A2.5a and A2.5b to show TH-5 Area Calculations. The current sheet shows TH-4 Area Calculations. 4. Please revise the plans to state that all metal roof fasteners must be color matched to the roof panels. 5. Please revise the plans to provide screen porch elevations detailing the materials to be used on the screen enclosures, including any kickplates if applicable. 6. Please revise sheet A6.5 to include the length and width dimensions of the buildings, which should match the previously approved elevations in the Development Order approval. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤1,039.95 | 04/01/2014 |
| IMPACT FEE PARKS | ¤6,719.90 | 04/01/2014 |
| IMPACT FEE SCHOOL | ¤4,655.00 | 04/01/2014 |
| IMPACT FEE TRANSPORTATION | ¤13,578.00 | 04/01/2014 |
| INSPECTION FEE 20 | ¤20.00 | 04/01/2014 |
| MECHANICAL FEE | ¤518.40 | 09/13/2013 |
| PERMIT FEE | ¤4,202.00 | 09/13/2013 |
| PLAN CHECK FEE | ¤878.60 | 09/13/2013 |
| PLUMBING FEE | ¤518.40 | 09/13/2013 |
| FIRE PLANS REVIEW | ¤83.25 | 09/13/2013 |
| ADMIN COMMERCIAL | ¤60.00 | 09/13/2013 |
| ELECTRIC FEE | ¤518.40 | 09/13/2013 |
| SURCHARGE FS 533.721 | ¤100.44 | 09/13/2013 |
| SURCHARGE - FS 468.631 | ¤100.44 | 09/13/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤33,712.78 |