I want to search for...

Permit #2013060550

Permit Details

Status: COED

Parcel Id: 48-11-31-1710-00000-0750
CONDITIONED SPACE: 2981 sqft
GARAGE: 945 sqft
SCREEN PORCH (SOLID ROOF) : 515 sqft
OPENED PORCH (WITH ROOF) : 81 sqft
Total Square Footage: 4522 sqft
Block: 00000
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: 386-947-4481
Location Address: 7 SCARLET OAK CIR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/19/2013
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: LEMA ARNOLD H & ANN S H&W

Address

85 DE LA MER UNIT 105

PALM COAST, FL 32137

Lot: 0750
Contracted Stated Job Value: ¤375,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 02/03/2014 FINAL APPROVED DSPENCER
GAS FINAL 01/31/2014 FINAL APPROVED RMARVEL
BLD - BUILDING FINAL 01/30/2014 FINAL APPROVED CMINI
Note: approved by Mike Navarra letter of conpliance approved by Brian Pohl eng.
FINAL SURVEY (OFFICE USE ONLY) 01/29/2014 APPROVED JHINDMAN
FINAL APRON (AFTER POUR/DRIVEWAY) 01/28/2014 APPROVED GLALIMA
ROW FINAL 01/28/2014 APPROVED GLALIMA
WALL SHEATHING 01/28/2014 CANCELLED BY APPLICANT RMARVEL
Note: Inspection Resulted at 1/28/2014 2:45:06 PM WRONG ADDRESS FOR INSPECTION.
PRE-APRON (PRE-POUR/DRIVEWAY) 01/10/2014 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
PRE-APRON (PRE-POUR/DRIVEWAY) 01/09/2014 PARTIALLY APPROVED GLALIMA
Note: READY TO POUR
ELECTRIC - EARLY POWER 12/20/2013 APPROVED DROCKWELL
Note: Inspection Requested at 12/19/2013 10:09:18 AM PRIVATE PROVIDER TO PERFORM INSPECTION approved by Mike Navarra
LATH/BRICK/ WATER BARRIER 11/21/2013 AUDIT - PRIVATE PROVIDER INSPECTION RMARVEL
Note: Inspection Resulted at 11/21/2013 12:45:13 PM ITEMS FROM PREVIOUS AUDIT HAVE BEEN DONE. approved by Mike Navarra
LATH/BRICK/ WATER BARRIER 11/19/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 11/19/2013 2:50:21 PM STAPLES NEED TO PENATRATE FRAMING MEMBERS 7"O.C. ...NEED TO LAP OVER EXPOSED WOOD AREAS..NEED DOUBLE VAPOR BARRIER AT FRONT WINDOWS...FBC 7031.6.3 AND ASTM STANDARDS 1063 approved by Robert Waldrop
GAS ROUGH 11/06/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 11/6/2013 3:09:37 PM GAS LINE NOT BONDED
ALL ROUGH 11/06/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 11/6/2013 3:09:38 PM NEED REVISION SHOWING CHANGES TO ELECTRIC,,CHECK ALL...ALSO SHOW AIR SUPPLY DELETED AND CLOSE TTHAT WAS CHANGED TO WET BAR
INSULATION 11/06/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 11/6/2013 3:09:39 PM NEED REVISION SHOWING CHANGES TO ELECTRIC,,CHECK ALL...ALSO SHOW AIR SUPPLY DELETED AND CLOSE TTHAT WAS CHANGED TO WET BAR..INSULATION INSTALLED WITH FIRESTOPPING CORRECT
ALL ROUGH 11/05/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 11/5/2013 3:25:48 PM STRAPS AND BUCKETS MISSING IN GARAGE....5`` HEAD PRESSURE NEEDED ON DWV...MISSING ELECTRIC AND HVAC PLAN..NEED TO REMOVE INSULATION TO CHECK WIRING TO CAN LIGHTS IN AREAS..
ALL ROUGH 11/04/2013 CANCELLED BY INSPECTOR CMINI
Note: all trades passed, framing failed - needs strapping as indicated on plans by Mike Navarra BN 3977 Inspection Resulted at 11/4/2013 3:07:09 PM TALKED TO SUPERINTENDENT..NEED TO CALL BUILDING OFFICIAL FOR MISSED AUDITS
ELECTRIC-TUG 10/17/2013 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 10/17/2013 3:39:42 PM CALLED FPL AT 3:00 TO RELEASE POWER..SPOKE WITH SUSAN approved by Mike Navarra
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/30/2013 AUDIT - PRIVATE PROVIDER INSPECTION RMARVEL
Note: Inspection Resulted at 9/30/2013 2:56:54 PM NO PLANS ON SITE FOR INSPECTION. NOT READY. NO PAPER ON ROOF. NO VALLEY FLASHING OR DRIP EDGE INSTALLED. approved by Mark Criswell see signed and sealed inspection report on file
ELEV CERT-FOUNDATION APPROVAL 09/17/2013 APPROVED DBEVAN
Note: Per Denise Bevan Elevation Certificate "B" is approved and released.
TIE BEAM / LINTEL 08/29/2013 AUDIT - PRIVATE PROVIDER INSPECTION RMARVEL
Note: Inspection Resulted at 8/29/2013 2:54:28 PM CLEAN CELLS AT FRONT COLUMNS. approved by Robert Waldrop
FOUND SURVEY APPROVED (OFFICE) 08/28/2013 APPROVED FREODICA
GRAVITY SEWER TEST 08/09/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 8/9/2013 9:48:17 AM NO PRESSURE ON PIPE..FBC P2503.4 approved by Mike Navarra
MONOLITHIC SLAB 08/07/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 8/7/2013 11:34:28 AM NOT READY FOR AUDIT,FBC 107.3..STILL MAKING MATS FOR FOOTERS IN BACK,FOOTING STEEL SITTING ON EARTH,UPRIGHTS NOT IN PLACE,STEEL CLOSER THAN 3" TO EARTH IN OTHER AREAS..FBC 403 approved by Mike Navarra 8/7/13 see signed and sealed inspection report on file
U - SEWER TIE IN 08/07/2013 APPROVED KKING
MONOLITHIC SLAB 08/06/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: NOT READY approved by Mike Navarra 8/7/13
PLUMBING 1ST ROUGH UNDERGROUND 07/31/2013 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 7/31/2013 2:37:08 PM OK approved by Mike Navarra

Review History

Department Status Date In Date Out
PLFM COMPLETE 01/29/2014 01/31/2014
SW1 COMPLETE 01/29/2014 01/29/2014
Note: Released By: JHINDMAN final s
ELEC COMPLETE 11/13/2013 11/15/2013
PLFM COMPLETE 09/17/2013 09/17/2013
Note: No comments.
PLFM HOLD 08/28/2013 09/13/2013
Note: Please complete elevations for Section “C” subsection “e” through “h”. If machinery slab exists at this stage, please indicate within subsection “e” the applicable elevation and within Section “D” Comments, provide equipment type. Please note that pool equipment is not a permissible type of machinery for elevation data.
SW1 COMPLETE 08/28/2013 08/28/2013
Note: Released By: FREODICA foundation survey
ZON COMPLETE 08/28/2013 08/28/2013
Note: Released By: FREODICA foundation survey
ZON COMPLETE 07/16/2013 07/18/2013
ZON HOLD 07/11/2013 07/16/2013
Note: Correct site plan to include 25 x 85 rear deck
ZON HOLD 07/03/2013 07/03/2013
Note: Revise all plans to reduce the depth of the garage to 30ft in accordance with Land development code. Revise site plan to show all dimension and setbacks of the driveway.
PLFM COMPLETE 07/03/2013 07/03/2013
PLFM HOLD 06/27/2013 07/02/2013
Note: floor elevations are not the same on the Elevation Certificate and survey
ELEC COMPLETE 06/27/2013 06/27/2013
URB COMPLETE 06/27/2013 06/28/2013
BLD COMPLETE 06/27/2013 06/27/2013
MECH COMPLETE 06/27/2013 06/27/2013
ZON HOLD 06/27/2013 06/28/2013
Note: Revise site plan to show all dimension and setbacks of the driveway.
PLFM HOLD 06/24/2013 06/24/2013
Note: Revise section B1 to City of Palm Coast 120684.
BLD HOLD 06/20/2013 06/20/2013
Note: 1. Provide attic ventilation calculations. 2010 FBC R806. 2. Revise wind load data on the cover page for the current building code for chapter 16.
ELEC HOLD 06/20/2013 06/20/2013
Note: Revise outlet locations to meet NEC 210.52
ENGIN1 COMPLETE 06/20/2013 06/21/2013
Note: No swale plan required.
MECH HOLD 06/20/2013 06/21/2013
Note: Provide insulated copper tracer wire and size for non metallic piping per 2010 FBC Fuel Gas Section 404.15.3.
PLUM COMPLETE 06/20/2013 06/21/2013
SW1 COMPLETE 06/20/2013 06/20/2013
UD1 COMPLETE 06/20/2013 06/21/2013
Note: see comment in general notes Keith King 386-9318009
URB HOLD 06/20/2013 06/20/2013
Note: Need to submit a irrigation plan as this lot is over 1/2 acre using the standards set on pages 41--42 of the technical manual paragraph A through S
ZON HOLD 06/20/2013 06/24/2013
Note: Revise all plans to reduce the depth of the garage to 30ft in accordance with Land development code. Revise site plan to show all dimension and setbacks of the driveway.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 01/31/2014
SITE PLAN 20 ¤20.00 07/19/2013
SURCHARGE FS 533.721 ¤26.81 07/19/2013
SURCHARGE - FS 468.631 ¤26.81 07/19/2013
STORM WATER PERMIT FEES ¤80.00 07/19/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 07/19/2013
ADMIN FEE ¤20.00 07/19/2013
ELECTRIC FEE ¤286.80 07/19/2013
3% FIRE IMPACT FEE CREDIT (¤6.24) 07/19/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 07/19/2013
IMPACT FEE PARKS ¤1,343.98 07/19/2013
IMPACT FEE SCHOOL ¤3,600.00 07/19/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 07/19/2013
MECHANICAL FEE ¤286.80 07/19/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 07/19/2013
PLAN CHECK FEE ¤151.20 07/19/2013
PLUMBING FEE ¤286.80 07/19/2013
NEW RESIDENTIAL INSPECTIONS ¤756.00 07/19/2013
Fees Total Due: ¤0.00 Total Paid: ¤10,013.17