I want to search for...
Permit #2013060550
Permit Details
Status: COED
| Parcel Id: 48-11-31-1710-00000-0750 |
| CONDITIONED SPACE: 2981 sqft |
| GARAGE: 945 sqft |
| SCREEN PORCH (SOLID ROOF) : 515 sqft |
| OPENED PORCH (WITH ROOF) : 81 sqft |
| Total Square Footage: 4522 sqft |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: 386-947-4481 |
| Location Address: 7 SCARLET OAK CIR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/19/2013 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: LEMA ARNOLD H & ANN S H&W |
|
Address 85 DE LA MER UNIT 105 PALM COAST, FL 32137 |
| Lot: 0750 |
| Contracted Stated Job Value: ¤375,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BENJAMIN EDWARD SMITH
| Status | Location Address | State License Number | Phone |
| CANCEL |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13004288 (Exp: 08/31/2016) | 386-265-2687 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 02/03/2014 | FINAL APPROVED | DSPENCER |
| GAS FINAL | 01/31/2014 | FINAL APPROVED | RMARVEL |
| BLD - BUILDING FINAL | 01/30/2014 | FINAL APPROVED | CMINI |
| Note: approved by Mike Navarra letter of conpliance approved by Brian Pohl eng. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/29/2014 | APPROVED | JHINDMAN |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 01/28/2014 | APPROVED | GLALIMA |
| ROW FINAL | 01/28/2014 | APPROVED | GLALIMA |
| WALL SHEATHING | 01/28/2014 | CANCELLED BY APPLICANT | RMARVEL |
| Note: Inspection Resulted at 1/28/2014 2:45:06 PM WRONG ADDRESS FOR INSPECTION. | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 01/10/2014 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 01/09/2014 | PARTIALLY APPROVED | GLALIMA |
| Note: READY TO POUR | |||
| ELECTRIC - EARLY POWER | 12/20/2013 | APPROVED | DROCKWELL |
| Note: Inspection Requested at 12/19/2013 10:09:18 AM PRIVATE PROVIDER TO PERFORM INSPECTION approved by Mike Navarra | |||
| LATH/BRICK/ WATER BARRIER | 11/21/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | RMARVEL |
| Note: Inspection Resulted at 11/21/2013 12:45:13 PM ITEMS FROM PREVIOUS AUDIT HAVE BEEN DONE. approved by Mike Navarra | |||
| LATH/BRICK/ WATER BARRIER | 11/19/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 11/19/2013 2:50:21 PM STAPLES NEED TO PENATRATE FRAMING MEMBERS 7"O.C. ...NEED TO LAP OVER EXPOSED WOOD AREAS..NEED DOUBLE VAPOR BARRIER AT FRONT WINDOWS...FBC 7031.6.3 AND ASTM STANDARDS 1063 approved by Robert Waldrop | |||
| GAS ROUGH | 11/06/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 11/6/2013 3:09:37 PM GAS LINE NOT BONDED | |||
| ALL ROUGH | 11/06/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 11/6/2013 3:09:38 PM NEED REVISION SHOWING CHANGES TO ELECTRIC,,CHECK ALL...ALSO SHOW AIR SUPPLY DELETED AND CLOSE TTHAT WAS CHANGED TO WET BAR | |||
| INSULATION | 11/06/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 11/6/2013 3:09:39 PM NEED REVISION SHOWING CHANGES TO ELECTRIC,,CHECK ALL...ALSO SHOW AIR SUPPLY DELETED AND CLOSE TTHAT WAS CHANGED TO WET BAR..INSULATION INSTALLED WITH FIRESTOPPING CORRECT | |||
| ALL ROUGH | 11/05/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 11/5/2013 3:25:48 PM STRAPS AND BUCKETS MISSING IN GARAGE....5`` HEAD PRESSURE NEEDED ON DWV...MISSING ELECTRIC AND HVAC PLAN..NEED TO REMOVE INSULATION TO CHECK WIRING TO CAN LIGHTS IN AREAS.. | |||
| ALL ROUGH | 11/04/2013 | CANCELLED BY INSPECTOR | CMINI |
| Note: all trades passed, framing failed - needs strapping as indicated on plans by Mike Navarra BN 3977 Inspection Resulted at 11/4/2013 3:07:09 PM TALKED TO SUPERINTENDENT..NEED TO CALL BUILDING OFFICIAL FOR MISSED AUDITS | |||
| ELECTRIC-TUG | 10/17/2013 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 10/17/2013 3:39:42 PM CALLED FPL AT 3:00 TO RELEASE POWER..SPOKE WITH SUSAN approved by Mike Navarra | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/30/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | RMARVEL |
| Note: Inspection Resulted at 9/30/2013 2:56:54 PM NO PLANS ON SITE FOR INSPECTION. NOT READY. NO PAPER ON ROOF. NO VALLEY FLASHING OR DRIP EDGE INSTALLED. approved by Mark Criswell see signed and sealed inspection report on file | |||
| ELEV CERT-FOUNDATION APPROVAL | 09/17/2013 | APPROVED | DBEVAN |
| Note: Per Denise Bevan Elevation Certificate "B" is approved and released. | |||
| TIE BEAM / LINTEL | 08/29/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | RMARVEL |
| Note: Inspection Resulted at 8/29/2013 2:54:28 PM CLEAN CELLS AT FRONT COLUMNS. approved by Robert Waldrop | |||
| FOUND SURVEY APPROVED (OFFICE) | 08/28/2013 | APPROVED | FREODICA |
| GRAVITY SEWER TEST | 08/09/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 8/9/2013 9:48:17 AM NO PRESSURE ON PIPE..FBC P2503.4 approved by Mike Navarra | |||
| MONOLITHIC SLAB | 08/07/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 8/7/2013 11:34:28 AM NOT READY FOR AUDIT,FBC 107.3..STILL MAKING MATS FOR FOOTERS IN BACK,FOOTING STEEL SITTING ON EARTH,UPRIGHTS NOT IN PLACE,STEEL CLOSER THAN 3" TO EARTH IN OTHER AREAS..FBC 403 approved by Mike Navarra 8/7/13 see signed and sealed inspection report on file | |||
| U - SEWER TIE IN | 08/07/2013 | APPROVED | KKING |
| MONOLITHIC SLAB | 08/06/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: NOT READY approved by Mike Navarra 8/7/13 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 07/31/2013 | AUDIT - PRIVATE PROVIDER INSPECTION | CMINI |
| Note: Inspection Resulted at 7/31/2013 2:37:08 PM OK approved by Mike Navarra |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 01/29/2014 | 01/31/2014 |
| SW1 | COMPLETE | 01/29/2014 | 01/29/2014 |
| Note: Released By: JHINDMAN final s | |||
| ELEC | COMPLETE | 11/13/2013 | 11/15/2013 |
| PLFM | COMPLETE | 09/17/2013 | 09/17/2013 |
| Note: No comments. | |||
| PLFM | HOLD | 08/28/2013 | 09/13/2013 |
| Note: Please complete elevations for Section “C” subsection “e” through “h”. If machinery slab exists at this stage, please indicate within subsection “e” the applicable elevation and within Section “D” Comments, provide equipment type. Please note that pool equipment is not a permissible type of machinery for elevation data. | |||
| SW1 | COMPLETE | 08/28/2013 | 08/28/2013 |
| Note: Released By: FREODICA foundation survey | |||
| ZON | COMPLETE | 08/28/2013 | 08/28/2013 |
| Note: Released By: FREODICA foundation survey | |||
| ZON | COMPLETE | 07/16/2013 | 07/18/2013 |
| ZON | HOLD | 07/11/2013 | 07/16/2013 |
| Note: Correct site plan to include 25 x 85 rear deck | |||
| ZON | HOLD | 07/03/2013 | 07/03/2013 |
| Note: Revise all plans to reduce the depth of the garage to 30ft in accordance with Land development code. Revise site plan to show all dimension and setbacks of the driveway. | |||
| PLFM | COMPLETE | 07/03/2013 | 07/03/2013 |
| PLFM | HOLD | 06/27/2013 | 07/02/2013 |
| Note: floor elevations are not the same on the Elevation Certificate and survey | |||
| ELEC | COMPLETE | 06/27/2013 | 06/27/2013 |
| URB | COMPLETE | 06/27/2013 | 06/28/2013 |
| BLD | COMPLETE | 06/27/2013 | 06/27/2013 |
| MECH | COMPLETE | 06/27/2013 | 06/27/2013 |
| ZON | HOLD | 06/27/2013 | 06/28/2013 |
| Note: Revise site plan to show all dimension and setbacks of the driveway. | |||
| PLFM | HOLD | 06/24/2013 | 06/24/2013 |
| Note: Revise section B1 to City of Palm Coast 120684. | |||
| BLD | HOLD | 06/20/2013 | 06/20/2013 |
| Note: 1. Provide attic ventilation calculations. 2010 FBC R806. 2. Revise wind load data on the cover page for the current building code for chapter 16. | |||
| ELEC | HOLD | 06/20/2013 | 06/20/2013 |
| Note: Revise outlet locations to meet NEC 210.52 | |||
| ENGIN1 | COMPLETE | 06/20/2013 | 06/21/2013 |
| Note: No swale plan required. | |||
| MECH | HOLD | 06/20/2013 | 06/21/2013 |
| Note: Provide insulated copper tracer wire and size for non metallic piping per 2010 FBC Fuel Gas Section 404.15.3. | |||
| PLUM | COMPLETE | 06/20/2013 | 06/21/2013 |
| SW1 | COMPLETE | 06/20/2013 | 06/20/2013 |
| UD1 | COMPLETE | 06/20/2013 | 06/21/2013 |
| Note: see comment in general notes Keith King 386-9318009 | |||
| URB | HOLD | 06/20/2013 | 06/20/2013 |
| Note: Need to submit a irrigation plan as this lot is over 1/2 acre using the standards set on pages 41--42 of the technical manual paragraph A through S | |||
| ZON | HOLD | 06/20/2013 | 06/24/2013 |
| Note: Revise all plans to reduce the depth of the garage to 30ft in accordance with Land development code. Revise site plan to show all dimension and setbacks of the driveway. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 01/31/2014 |
| SITE PLAN 20 | ¤20.00 | 07/19/2013 |
| SURCHARGE FS 533.721 | ¤26.81 | 07/19/2013 |
| SURCHARGE - FS 468.631 | ¤26.81 | 07/19/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/19/2013 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 07/19/2013 |
| ADMIN FEE | ¤20.00 | 07/19/2013 |
| ELECTRIC FEE | ¤286.80 | 07/19/2013 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 07/19/2013 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 07/19/2013 |
| IMPACT FEE PARKS | ¤1,343.98 | 07/19/2013 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/19/2013 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 07/19/2013 |
| MECHANICAL FEE | ¤286.80 | 07/19/2013 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 07/19/2013 |
| PLAN CHECK FEE | ¤151.20 | 07/19/2013 |
| PLUMBING FEE | ¤286.80 | 07/19/2013 |
| NEW RESIDENTIAL INSPECTIONS | ¤756.00 | 07/19/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,013.17 |