I want to search for...

Permit #2013070003

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00070-0050
CONDITIONED SPACE: 2142 sqft
GARAGE: 612 sqft
SCREEN PORCH (SOLID ROOF) : 203 sqft
OPENED PORCH (WITH ROOF) : 232 sqft
OPENED PORCH (WITH ROOF) : 35 sqft
Total Square Footage: 3224 sqft
Block: 00070
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: (386)437-3323
Location Address: 17 EMMONS LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/22/2013
NOC: RECORDED
Applicant name: PETER JOSEPH LYDEN
Owner: PCM HOMES

Address

210 OLD KINGS ROAD S

PALM COAST, FL 32136

Address

SUITGE 600

PALM COAST, FL 32136

Lot: 0050
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

DEL CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

PO BOX 1009

BUNNELL, FL 32110

CBC1253392 (Exp: 08/31/2024) 386-931-2568

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone
CANCEL

17 UNIMAY CT

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2022) 386-931-2568
RICHARD LEE VONBROCKEN
Status Location Address State License Number Phone Fax
INACTIVE

1738 STATE AVE

HOLLY HILL, FL 32117

CAC035516 (Exp: 08/31/2026) (386)672-1950 (386)672-1952
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
IAN MICHEAL JOHNSON
Status Location Address State License Number Phone Fax
ACTIVE

4244 JACKSON STREET

PORT ORANGE, FL 32127

CCC1325915 (Exp: 08/31/2026) 386-760-0764 386-760-3080

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 02/18/2014 FINAL APPROVED DSPENCER
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 02/07/2014 APPROVED DSPENCER
U -UTILITY RESIDENTIAL FINAL 12/31/2013 Disapproved -FEE REQUIRED DSPENCER
Note: Inspection Resulted at 12/31/2013 11:55:02 AM THE SEWER TIE IN INSPECTION HAS NOT BEEN COMPLETED NO CLEANOUT FOUND BEHIND THE PEP TANK AS REQUIRED AT GRADE WITH FLUSH MOUNT SLOTTED CLEANOUT CAP. CANNOT DO A FINAL INSPECTION WITHOUT THAT VISUAL INSPECTION COMPLETED IN THE SYSTEM UNCOVER THE TANK CONNECTION AND THE CLEANOUT AND CALL FOR SEWER TIE IN INSPECTION AND THEN RECALL THIS FINAL INSPECTION IN.FOR INSPECTION. DANNY SPENCER 386-569-9082
BLD - BUILDING FINAL 12/20/2013 FINAL APPROVED CMINI
FINAL APRON (AFTER POUR/DRIVEWAY) 12/19/2013 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW FINAL 12/18/2013 APPROVED - AS NOTED RGROSS
Note: Passed as noted that the power company tore the swale up on the vacant next door installing a new power pole. Builder had extra sod and therefore covered it. New Home regrade will correct the elevation differences.
FINAL SURVEY (OFFICE USE ONLY) 12/18/2013 APPROVED JMCGOWEN
FINAL APRON (AFTER POUR/DRIVEWAY) 11/22/2013 Disapproved - NO FEE RGROSS
Note: Need hot patch along the length of the driveway at the road edge.
GRAVITY SEWER TEST 11/19/2013 APPROVED CMINI
ELECTRIC - EARLY POWER 11/19/2013 APPROVED - AS NOTED CMINI
Note: called fpl to release power at 2:00 spoke with Karen
PRE-APRON (PRE-POUR/DRIVEWAY) 11/12/2013 APPROVED - AS NOTED RGROSS
Note: Survey shows 3 ft sidewalk from driveway to enctrance. Builder had 4 ft wide forms. Site meet w/builder (Steven) and explained that sidewalk to entrance will pass as long as it is put back to 3 ft sidewalk width. Builder said He would change to match survey specs.
LATH/BRICK/ WATER BARRIER 10/25/2013 APPROVED CMINI
INSULATION 10/08/2013 APPROVED CMINI
ALL ROUGH 10/07/2013 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/25/2013 APPROVED CMINI
TIE BEAM / LINTEL 09/18/2013 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 09/13/2013 APPROVED FREODICA
MONOLITHIC SLAB 08/20/2013 APPROVED CMINI
PLUMBING 1ST ROUGH UNDERGROUND 08/15/2013 APPROVED CMINI

Review History

Department Status Date In Date Out
ZON COMPLETE 02/11/2014 02/13/2014
SW1 COMPLETE 12/18/2013 12/18/2013
Note: Released By: JMCGOWEN final survey
ZON HOLD 11/20/2013 11/25/2013
Note: Accesary structures are not permit in the front location of the house. Revise site plan and building plans to meet Chapter 13 Architectural regulations.
BLD COMPLETE 11/13/2013 11/15/2013
ZON HOLD 11/13/2013 11/19/2013
Note: Accesary structures are not permit in the front location of the house. Revise site plan and building plans to meet Chapter 13 Architectural regulations.
ZON COMPLETE 09/13/2013 09/13/2013
Note: Released By: FREODICA foundation survey
SW1 COMPLETE 09/13/2013 09/13/2013
Note: Released By: FREODICA foundation survey
UD1 COMPLETE 07/17/2013 07/18/2013
Note: see comment in general notes Kieth King 386-9318009
ELEC COMPLETE 07/17/2013 07/17/2013
BLD COMPLETE 07/17/2013 07/17/2013
URB COMPLETE 07/17/2013 07/18/2013
MECH COMPLETE 07/17/2013 07/17/2013
ZON COMPLETE 07/17/2013 07/19/2013
BLD HOLD 07/01/2013 07/02/2013
Note: Held by J. Hindman 1.Provide for hazardous location glazing per 2010 FBC R 308.4. 2. Provide pressure treated wood per 2010 FBC R 317 and 320. 3. Provide a non bearing wall detail per 2010 FBC R602.1.3.
ELEC HOLD 07/01/2013 07/02/2013
Note: Revise receptacle location to meet NEC 210.52 provide electric load calculations, locate pep tank control panel NEC 220
ENGIN1 COMPLETE 07/01/2013 07/08/2013
MECH HOLD 07/01/2013 07/02/2013
Note: 1. EPL Display Card on energy calculation shall be signed by the builder per 2010 FBC EC 405.4.3(1). 2. Provide return air from master bedroom to comply with 2010 FBCR M1602.4.
PLUM COMPLETE 07/01/2013 07/02/2013
SW1 COMPLETE 07/01/2013 07/02/2013
UD1 HOLD 07/01/2013 07/02/2013
Note: Show the PEP panel on the elec plans Keith King 386-9318009
URB HOLD 07/01/2013 07/02/2013
Note: Need to indicate on the plan a permanent irrigation system is being installed with 100% coverage. when using a non-drought tolerant sod type St. Augustine etc.
ZON HOLD 07/01/2013 07/02/2013
Note: Revise color sheeet to have garage match trim or wall color. Color choosen for the gaarage is consider a pastel and must meet the LRV of 80% or greater. Revise plans to show direct access to main house from game room and fourth bedroom. Revise landscape plan to show landscaping wrapping corners of the house. Revise site plan and lanscape plan to remove walkway from driveway. Walkway must be seperate by plantings.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 02/25/2014
REINSPECTION FEE ¤40.00 02/25/2014
NEW RESIDENTIAL INSPECTIONS ¤540.00 07/22/2013
SITE PLAN 20 ¤20.00 07/22/2013
SURCHARGE FS 533.721 ¤20.01 07/22/2013
SURCHARGE - FS 468.631 ¤20.01 07/22/2013
STORM WATER PERMIT FEES ¤80.00 07/22/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 07/22/2013
ADMIN FEE ¤20.00 07/22/2013
ELECTRIC FEE ¤222.00 07/22/2013
3% FIRE IMPACT FEE CREDIT (¤6.24) 07/22/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 07/22/2013
IMPACT FEE PARKS ¤1,343.98 07/22/2013
IMPACT FEE SCHOOL ¤3,600.00 07/22/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 07/22/2013
MECHANICAL FEE ¤222.00 07/22/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 07/22/2013
PLAN CHECK FEE ¤108.00 07/22/2013
PLUMBING FEE ¤222.00 07/22/2013
Fees Total Due: ¤0.00 Total Paid: ¤9,585.97