Permit #2013080167

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7013-00210-0150
Block: 00210
Subdivision: 2192 - SECTION 13-BELLE TERRE
Job Phone: 386-503-0906
Location Address: 50 BRUSHWOOD LN
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 09/09/2013
NOC: RECORDED
Applicant name: ANTHONY FALLONE
Owner: WELCH, MARK L & JANIE M

Address

50 BRUSHWOOD LANE

PALM COAST, FL 32137

Lot: 0150
Contracted Stated Job Value: ¤8,000.00
Job Description: REMOVING SECTION OF BACK WALL & REPLACING W/ A SLIDER
Type: CN

Contractor

FONTANA CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 351222

PALM COAST, FL 32137

CBC1250596 (Exp: 08/31/2022) 386-503-0906 (386)986-1305

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/09/2014 FINAL APPROVED RMARVEL
LATH/BRICK/ WATER BARRIER 11/20/2013 APPROVED DROCKWELL
INSULATION 11/06/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
INSULATION 11/05/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 11/5/2013 2:50:09 PM PROVIDE FIRE BLOCKING /FIRE FOAM WHERE ENTRANCE INTO ATTIC SPACES. USE APPROVED FIRE RATED FOAM.FIREBLOCKING NEEDED…..F.B.C. 302.11
ALL ROUGH 10/30/2013 APPROVED RMARVEL
WALL SHEATHING 10/17/2013 APPROVED CMINI
Note: THIS IS A REINSPECTION
WALL SHEATHING 10/16/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 10/16/2013 3:10:05 PM WALL SHEATHING NEEDS TO BE ATTACHED PER APPROVED PLANS. MISSING ATTACHMENT ANCHORS IN MULTIPLE AREAS.
MONOLITHIC SLAB 09/25/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 09/17/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 9/17/2013 2:44:03 PM NOT READY. FORMS ARE NOT IN PLACE. PREP HAS NOT BEEN DONE ACCORDING TO PLANS.(PRESSURE WASH AND BONDING AGENT)

Review History

Department Status Date In Date Out
ELEC COMPLETE 09/06/2013 09/06/2013
ELEC HOLD 09/05/2013 09/06/2013
Note: Revise receptacle locations on added wall to meet NEC 210.52, receptacles shall be located no more the 6 feet from openings and no more than 12 foot between receptacles
ELEC HOLD 09/03/2013 09/03/2013
Note: provide receptacles on the walls of the existing florida room to remain. per 2008 NEC 210.52.
MECH COMPLETE 08/27/2013 08/28/2013
ZON COMPLETE 08/27/2013 08/30/2013
ELEC HOLD 08/27/2013 08/28/2013
Note: 1. Provide a receptacle on the left side wall at the new slider and provide receptacles on the walls of the existing florida room to remain. per 2008 NEC 210.52.
BLD COMPLETE 08/27/2013 08/28/2013
MECH HOLD 08/07/2013 08/07/2013
Note: The City's record on the proposed project is an open porch under existing roof but the plan shows two existing supply air diffusersers and an existing Florida room at the adjacent space. Clarify what is existing and provide energy calculations including the existing Florida room and duct sizes to verify if hvac heating/cooling load meets the capacity of existing hvac units per 2010 FBC 107.2.1.
BLD HOLD 08/07/2013 08/07/2013
Note: 1. Provide a detail that shows the existing emergency egress for the bedroom or provide a new one.2010 FBC R310
ELEC HOLD 08/07/2013 08/07/2013
Note: Provide electric contractor doing the work, revise receptacle locations to meet NEC 210.52
ZON HOLD 08/07/2013 08/09/2013
Note: Provide a site plan for zoning approval. On the site plan note the proposed location of the sliding glass doors.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/08/2014
REINSPECTION FEE ¤40.00 01/08/2014
REINSPECTION FEE ¤40.00 01/08/2014
REMODEL/ADDITION/ACCES INSPECT ¤40.00 09/09/2013
SITE PLAN 20 ¤20.00 09/09/2013
SURCHARGE FS 533.721 ¤2.00 09/09/2013
SURCHARGE - FS 468.631 ¤2.00 09/09/2013
ADMIN FEE ¤20.00 09/09/2013
PLAN CHECK FEE ¤40.00 09/09/2013
Fees Total Due: ¤0.00 Total Paid: ¤244.00