I want to search for...
Permit #2013080234
Permit Details
Status: COED
| Parcel Id: 07-11-31-7016-00040-0320 |
| CONDITIONED SPACE: 2334 sqft |
| GARAGE: 542 sqft |
| OPENED PORCH (WITH ROOF) : 322 sqft |
| PATIO/DECK (NO ROOF) : 74 sqft |
| Total Square Footage: 3272 sqft |
| Block: 00040 |
| Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE |
| Job Phone: (386)445-9055 |
| Location Address: 10 COMMANDER CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/19/2013 |
| NOC: RECORDED |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: SOUSA, ROGERIO A & CARMEN N |
|
Address 4038 CARPENTER POND RD DURHAM, NC 27703 |
| Lot: 0320 |
| Contracted Stated Job Value: ¤219,000.00 |
| Job Description: SINGLE FAMILY HOUSE |
| Type: CN |
Contractor
NEW COASTAL HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
399 SW PALM COAST PKWY PALM COAST, FL 32137 |
STE5 PALM COAST, FL 32137 |
CRC1327024 (Exp: 08/31/2018) | (386)445-9055 | (386)445-9056 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1351 HAZELNUT ST BUNNELL, FL 32110 |
CFC1427527 (Exp: 08/31/2026) | 386-445-2532 | 386-445-5575 |
THOMAS CHARLES TALLAKSEN JR.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
503 SOUTH OLD DIXIE HWY BUNNELL, FL 32110 |
CCC1327743 (Exp: 08/31/2024) | 386-931-2990 | (386)437-2279 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 07/28/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 07/25/2014 | FINAL APPROVED | CMINI |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 07/24/2014 | APPROVED | RGROSS |
| ROW FINAL | 07/24/2014 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 07/24/2014 | APPROVED | RLEE |
| TIE BEAM / LINTEL | 07/22/2014 | APPROVED - AS NOTED | CMINI |
| Note: inspected on 12/18,it was added on but did not transfer into system that day | |||
| ELECTRIC - EARLY POWER | 07/03/2014 | APPROVED | CMINI |
| GRAVITY SEWER TEST | 05/21/2014 | APPROVED | CMINI |
| U - SEWER TIE IN | 05/21/2014 | APPROVED | DSPENCER |
| ELECTRIC-TUG | 05/08/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 5/8/2014 1:37:44 PM CALLED FPL TO RELEASE POWER AT 1:00,SPOKE WITH SUSAN | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 05/01/2014 | APPROVED - AS NOTED | GLALIMA |
| Note: CALLED IN BY OWNER / G.M DID SERVEY ON CULVERT PIPES 4 / 30 / 2014 READY TO POUR | |||
| PLUMBING 2ND ROUGH | 04/28/2014 | APPROVED | CMINI |
| INSULATION | 04/21/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 04/17/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 4/17/2014 3:41:42 PM NOT READY,INSULATION AND FIREBLOCKING NOT COMPLTE | |||
| ALL ROUGH | 04/15/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 4/15/2014 3:24:06 PM NAIL PLATES NEEDED WHERE HOLE IS LESS THAN 1-1/4" FROM AND EDGE OF FRAMING MEMBER IS LESS THAN 1-1/4" FROM WIRE NEC300.4 | |||
| LATH/BRICK/ WATER BARRIER | 04/11/2014 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/17/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/13/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 2/13/2014 3:40:17 PM TRUSS H15C MISSING STRAP..NEED CONNECTION AT SILL PLATES FOR CONTINUOUS LOAD PATH AT HEADERS IN GARAGE AND RIGHT OF FRONT ENTRY..FILL CELL ATTEMPTED TO BE FILLED NOT SOLID AT RIGHT SIDE OF HOUSE POOL BATH | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/16/2013 | APPROVED | JMCGOWEN |
| MONOLITHIC SLAB | 12/05/2013 | APPROVED | RMARVEL |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/02/2013 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/24/2014 | 07/24/2014 |
| Note: Released By: RLEE Linetl inspection passed see lintel inspection notes | |||
| SW1 | HOLD | 07/21/2014 | 07/21/2014 |
| Note: Held By: JHINDMAN we cannot approve the survey until the lintel inspection is approved in the system. JHINDMAN 986-3784. final survey | |||
| BLD | COMPLETE | 04/23/2014 | 04/23/2014 |
| ELEC | COMPLETE | 04/11/2014 | 04/14/2014 |
| SW1 | COMPLETE | 12/16/2013 | 12/16/2013 |
| Note: Released By: JMCGOWEN foundation survey | |||
| PLUM | COMPLETE | 08/16/2013 | 08/16/2013 |
| ZON | COMPLETE | 08/16/2013 | 08/19/2013 |
| BLD | COMPLETE | 08/09/2013 | 08/12/2013 |
| ELEC | COMPLETE | 08/09/2013 | 08/09/2013 |
| ENGIN1 | COMPLETE | 08/09/2013 | 08/14/2013 |
| MECH | COMPLETE | 08/09/2013 | 08/12/2013 |
| PLUM | HOLD | 08/09/2013 | 08/12/2013 |
| Note: Summer kitchen sink which is tied into the wet vented pool bathroom is not allowed per 2010 FBC R P3108.1 unless connected downstream of the bathroom group. | |||
| SW1 | COMPLETE | 08/09/2013 | 08/09/2013 |
| UD1 | COMPLETE | 08/09/2013 | 08/12/2013 |
| Note: See comment in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 08/09/2013 | 08/12/2013 |
| ZON | HOLD | 08/09/2013 | 08/13/2013 |
| Note: 1. The right-of-way utilization agreement and easement encroachment form must be signed by the owners the same exact way it appears on the deed. 2. On site and landscaping plan label all areas that are to be paved. 3. Revise site and landscape plan to remove the concrete from the middle of the circular driveway to be out of the 5’ Utility Easement. 4. Per the Land Development Code Chapter 12 Foundation shrubbery plantings are required along the side and/or rear of the foundation that faces a fresh or saltwater canal, lake, golf course, or public right-of-way. (LDC, Subsection 11.03.02.C.2.B) Revise plan accordingly. 5. What is the square/rectangular shape on the rear elevation of the house? If this is a window banding must be placed around windows that face a fresh or saltwater canal, lake, golf course, or public right-of-way. 6. Per the Landscape Specialist remove the two required rear trees from the rear side 5’ easement. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 07/28/2014 |
| CONTRACTOR CHANGE | ¤40.00 | 07/28/2014 |
| REVISION | ¤40.00 | 07/28/2014 |
| REVISION | ¤40.00 | 07/28/2014 |
| REINSPECTION FEE | ¤40.00 | 07/28/2014 |
| REINSPECTION FEE | ¤40.00 | 07/28/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤570.00 | 08/19/2013 |
| ADMIN FEE | ¤20.00 | 08/19/2013 |
| SITE PLAN 20 | ¤20.00 | 08/19/2013 |
| SURCHARGE FS 533.721 | ¤20.96 | 08/19/2013 |
| SURCHARGE - FS 468.631 | ¤20.96 | 08/19/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/19/2013 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 08/19/2013 |
| ELECTRIC FEE | ¤231.00 | 08/19/2013 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 08/19/2013 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 08/19/2013 |
| IMPACT FEE PARKS | ¤1,343.98 | 08/19/2013 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 08/19/2013 |
| RECORDING FEE REIMBURSE DOC | ¤62.50 | 08/19/2013 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 08/19/2013 |
| MECHANICAL FEE | ¤231.00 | 08/19/2013 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 08/19/2013 |
| PLAN CHECK FEE | ¤114.00 | 08/19/2013 |
| PLUMBING FEE | ¤231.00 | 08/19/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,873.37 |