I want to search for...
Permit #2013080687
Permit Details
Status: COED
| Parcel Id: 07-11-31-7009-00070-0090 |
| CONDITIONED SPACE: 2035 sqft |
| GARAGE: 463 sqft |
| OPENED PORCH (WITH ROOF) : 197 sqft |
| PATIO/DECK (NO ROOF) : 73 sqft |
| Total Square Footage: 2768 sqft |
| Block: 00070 |
| Subdivision: 2208 - SECTION 9-FLORIDA PARK |
| Job Phone: 386-672-6101 |
| Location Address: 33 FARISTON PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/23/2013 |
| NOC: RECORDED |
| Applicant name: JOHN DAVID MINABERRY |
| Owner: BYRNE, JAMES & LORI |
|
Address 33 FARISTON PL PALM COAST, FL 32137 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤220,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KEYSTONE HOMES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1339 W GRANADA BLVD ORMOND, FL 32174 |
CRC1329222 (Exp: 08/31/2026) | 386-672-6101 | 386-672-6102 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone |
| CANCEL |
17 UNIMAY CT BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2022) | 386-931-2568 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
WAYNE A PHILLIPS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
357 ANDREWS ST ORMOND BEACH, FL 32174 |
CVC56698 (Exp: 08/31/2026) | (386)673-9720 | (386)673-9840 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 06/13/2014 | APPROVED | DSPENCER |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 06/11/2014 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 06/11/2014 | APPROVED | RGROSS |
| BLD - BUILDING FINAL | 06/11/2014 | FINAL APPROVED | CMINI |
| FINAL SURVEY (OFFICE USE ONLY) | 06/09/2014 | APPROVED | JMCGOWEN |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 06/05/2014 | Disapproved -FEE REQUIRED | RGROSS |
| Note: Concrete cannot be allowed to enter the roadway. Need to cut the asphalt out at the end of the driveway and the entire width and replace with hot patch. See Paint marks. | |||
| ELECTRIC - EARLY POWER | 05/20/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 5/20/2014 3:29:13 PM CALLED FPL TO RELEASE POWER AT 2:20 PM,SPOKE WITH SUSAN | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/29/2014 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| U - SEWER TIE IN | 03/12/2014 | APPROVED | DSPENCER |
| GRAVITY SEWER TEST | 03/12/2014 | APPROVED | CMINI |
| LATH/BRICK/ WATER BARRIER | 01/21/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 01/17/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 1/17/2014 3:02:20 PM WORK NOT COMPLETED/NOT READY FOR INSPECTION | |||
| INSULATION | 01/13/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 01/09/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 1/9/2014 3:31:36 PM UNABLE TO CHECK FOR APPROVED FIRE RATED FOAM/CAULK ABOVE ELECTRICAL PANEL. MISSED MULTIPLE HOLES LEADING INTO ATTAC AREA. TOO MANY TO LIST. FIREBLOCKING NEEDED…..F.B.C. 302.11 | |||
| ALL ROUGH | 01/03/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 12/31/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/31/2013 3:29:55 PM NAIL PLATES NEEDED ON ELECTRIC, WIRES STAPLED WITHIN 1-1/4" FROM FRAMING EDGE...NEC 300.4 (D),METAL BOX IN MASTER CEILING NOT GROUNDED NEC 314.4...WIRE IN CLOSET 3RD BD.RM. HANGING BELOW CEILING LINE...FRONT ENTRY ARCH WINDOW 1 SCREW NOT CATCHING 2X | |||
| ALL ROUGH | 12/30/2013 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 12/30/2013 3:19:08 PM METAL BOXES SHALL BE GROUNDED MISSING IN MULTIPLE LOCATIONS,CHECK ALL.. NEC.314.4.NAIL PLATES NEEDED ON ELECTRIC, WIRES STAPLED WITHIN 1-1/4" FROM FRAMING EDGE.AND AT TOP OF PANEL..NEC 300.4..WINDOW HUNG UP ON TAPCON WILL NOT CLOSE,CHECK OTHER WINDOWS WITH TAPCONS NOT FULLY ANCHORED...FIRE BLOCK NEEDED AT CHASE BEHIND A/C STAND..HVAC DUCT LAYOUT MISSING FROM PLANS | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/16/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/16/2013 3:31:19 PM CORRECTIONS MADE | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/10/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: per contractor Inspection Resulted at 12/10/2013 3:01:03 PM LOOSE SHEATHING CIRCLED ON PLANS. ATTACH PER APPROVED PLANS. MISSING ENGINEERING ON TRUSS 09. REPAIR OVERNOTCHED BEARING WALL AT GARAGE. | |||
| ELECTRIC TEMP POLE | 11/06/2013 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 11/6/2013 3:09:34 PM CALLED FPL TO RELEASE POWER AT 11:45,SPOKE WITH KAREN | |||
| TIE BEAM / LINTEL | 10/31/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| TIE BEAM / LINTEL | 10/30/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 10/30/2013 2:40:30 PM CLEARANCE FROM REBAR TO MASONRY F.B.C 606.9.4 CIRCLED ON PLANS. EPOXIED DOWEL IS LOOSE. NOT BONDED TO CONCRETE. | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/29/2013 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 10/16/2013 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/11/2013 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 06/09/2014 | 06/09/2014 |
| Note: Released By: JMCGOWEN | |||
| URB | COMPLETE | 05/23/2014 | 05/27/2014 |
| ELEC | COMPLETE | 12/20/2013 | 12/20/2013 |
| ELEC | HOLD | 12/19/2013 | 12/19/2013 |
| Note: Provide signed and sealed drawing for electric revision FBC 107.1 | |||
| ZON | COMPLETE | 12/18/2013 | 12/18/2013 |
| BLD | COMPLETE | 12/06/2013 | 12/06/2013 |
| SW1 | COMPLETE | 10/29/2013 | 10/29/2013 |
| Note: Released By: FREODICA foundation survey | |||
| ZON | COMPLETE | 10/29/2013 | 10/29/2013 |
| Note: Released By: FREODICA foundation | |||
| ELEC | COMPLETE | 09/04/2013 | 09/04/2013 |
| ENGIN1 | COMPLETE | 09/04/2013 | 09/05/2013 |
| BLD | COMPLETE | 08/28/2013 | 08/29/2013 |
| ELEC | HOLD | 08/28/2013 | 08/29/2013 |
| Note: 1. Provide electrical panel location. 2008 NEC 110.26 2. Provide a receptacle at bedroom number three under the light switches. 2008 NEC 210.52. | |||
| ENGIN1 | HOLD | 08/28/2013 | 09/04/2013 |
| Note: No resubmittal required. | |||
| MECH | COMPLETE | 08/28/2013 | 08/29/2013 |
| PLUM | COMPLETE | 08/28/2013 | 08/29/2013 |
| SW1 | COMPLETE | 08/28/2013 | 08/29/2013 |
| UD1 | COMPLETE | 08/28/2013 | 08/29/2013 |
| Note: See comment in general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 08/28/2013 | 08/30/2013 |
| ZON | COMPLETE | 08/28/2013 | 09/03/2013 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 06/10/2014 |
| REINSPECTION FEE | ¤40.00 | 06/10/2014 |
| REINSPECTION FEE | ¤40.00 | 06/10/2014 |
| REINSPECTION FEE | ¤40.00 | 06/10/2014 |
| REINSPECTION FEE | ¤40.00 | 06/10/2014 |
| REINSPECTION FEE | ¤40.00 | 06/10/2014 |
| REINSPECTION FEE | ¤40.00 | 06/10/2014 |
| REINSPECTION FEE | ¤40.00 | 06/10/2014 |
| REVISION | ¤40.00 | 06/10/2014 |
| REVISION | ¤40.00 | 06/10/2014 |
| SITE PLAN 20 | ¤20.00 | 09/23/2013 |
| SURCHARGE FS 533.721 | ¤18.44 | 09/23/2013 |
| SURCHARGE - FS 468.631 | ¤18.44 | 09/23/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/23/2013 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 09/23/2013 |
| ADMIN FEE | ¤20.00 | 09/23/2013 |
| NEW RESIDENTIAL INSPECTIONS | ¤490.00 | 09/23/2013 |
| ELECTRIC FEE | ¤207.00 | 09/23/2013 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 09/23/2013 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 09/23/2013 |
| IMPACT FEE PARKS | ¤1,343.98 | 09/23/2013 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/23/2013 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 09/23/2013 |
| MECHANICAL FEE | ¤207.00 | 09/23/2013 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 09/23/2013 |
| PLAN CHECK FEE | ¤98.00 | 09/23/2013 |
| PLUMBING FEE | ¤207.00 | 09/23/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,797.83 |