I want to search for...

Permit #2013090120

Permit Details

Status: COED

Parcel Id: 07-11-31-1090-000C0-0000
Block: 000C0
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: (386) 446-3615
Location Address: 160 CYPRESS POINT PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 09/30/2013
NOC: RECORDED
Applicant name: RICHARD W HAUSEN
Owner: BETHEA PROPERTIES LLC

Address

4662 RIVER POINT RD W

JACKSONVILLE, FL 32207

Lot: 0000
Contracted Stated Job Value: ¤185,000.00
Job Description: C 113-117 -- CUE NOTE BILLIARD ROOM INTERIOR ALTERATIONS
Type: CN

Contractor

HAUSEN PROPERTIES INC
Status Location Address State License Number Phone Fax
INACTIVE

P. O. BOX 351868

Palm Coast, FL 32135

RG0029505 (Exp: 08/31/2025) (386) 446-3615 386-446-3615

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address State License Number Phone Fax
CANCEL

55 BARRISTER LN

PALM COAST, FL 32137

ER13013466 (Exp: 08/31/2014) 386-586-9144 (386)246-6305
DEREK ALLEN MCLEAN
Status Location Address State License Number Phone
CANCEL

2485 DOBBS RD

SAINT AUGUSTINE, FL 32086

CAC1816010 (Exp: 08/31/2022) 904-540-8199
THOMAS WALTER ALBANO
Status Location Address State License Number Phone Fax
INACTIVE

P. O. BOX 352075

Palm Coast, FL 32135

CFC045991 (Exp: 08/31/2024) 386-437-2795 (386)437-2781
BOB BELL
Status Location Address State License Number Phone
CANCEL

411 6TH STREET

HOLLY HILL, FL 32117

01612 (Exp: 09/18/2014) 386-252-5555

Inspection History

Type Request Date Result Inspector
ELECTRIC FINAL 09/18/2015 FINAL APPROVED RMARTIN
Note: THIS IS A REINSPECTION
BUILDING FINAL 09/18/2015 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION per contractor
BUILDING FINAL 09/10/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 9/10/2015 10:22:00 AM HANDICAP ACCESSIBLE BATH ROOM STALLS NOT TO PLAN.. ALSO NEED REVISION FOR DELETED HANDSINK IN KITCHEN
FIRE FINAL 09/08/2015 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION per contractor
ELECTRIC FINAL 09/04/2015 Disapproved -FEE REQUIRED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 9/4/2015 8:36:37 AM STILL LABELING IN PANELS NOT MATCHING APPROVED PANEL SCHEDULE, STILL NEED ARC SHIELDS OR PROTECTION IN OUTLET BOXES ON WALLS IN POOL TABEL AREA, COVER STILL NOT ON MAIN PANEL IN POOL TABLE AREA ......NEC 3OO
FIRE FINAL 09/03/2015 Disapproved -FEE REQUIRED JHINDMAN
Note: Provide panic hardware on the rear pool room door.
U - UTILITY COMMERCIAL FINAL 09/03/2015 FINAL APPROVED MBACON
U-GREASE INTERCEPTOR FLOW/DYE TESTED 08/31/2015 APPROVED MBACON
Note: THIS IS A REINSPECTION
ABOVE CEILING 08/26/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
HVAC FINAL 08/26/2015 APPROVED CMINI
PLUMBING FINAL 08/24/2015 APPROVED CMINI
ELECTRIC FINAL 08/24/2015 Disapproved -FEE REQUIRED RMARTIN
Note: Inspection Resulted at 8/24/2015 9:59:08 AM NEED TO HAVE CORRECT LABELING ON PANELS AND NEED TO MATCH APPROVED PLAN PANEL SCHEDULES, ALSO MANY OUTLETS NEED ARC SHEILDS OR FIRE CAULK......NEC.314
ELECTRIC 1ST ROUGH 08/24/2015 APPROVED RMARTIN
Note: THIS IS A REINSPECTION
GAS FINAL 08/24/2015 APPROVED CMINI
U-GREASE INTERCEPTOR FLOW/DYE TESTED 08/24/2015 APPROVED MBACON
Note: Inspection Resulted at 8/24/2015 3:12:47 PM NEED TO DYE TEST
PROJECT STATUS (OFFICE USE) 05/05/2015 APPROVED - AS NOTED JHINDMAN
Note: fire protection of steel beam inspected by affidavit.
INSULATION 08/12/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION per contractor
INSULATION 08/08/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 8/8/2014 3:06:40 PM NO ACCESS TO UNIT,DOORS LOCKED,TRIED IN MORNING ON WAY OUT OF OFFICE AND ALSO IN AFTERNOON ON WAY IN TO OFFICE
FRAMING 07/31/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ABOVE CEILING 07/31/2014 CANCELLED BY APPLICANT CMINI
HVAC ROUGH 07/31/2014 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 7/31/2014 2:26:17 PM NEED TO ADD EXHAUST FAN IN BATH THAT WAS DELETED OR SUBMIT REVISION TO DELETE IT FROM PLANS,HAVE BY HVAC FINAL
ELECTRIC 2ND ROUGH 07/31/2014 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 7/31/2014 3:11:32 PM SHOW REVISION FOR ADDED LIGHTS
GAS ROUGH 07/16/2014 APPROVED RMARVEL
ELECTRIC 1ST ROUGH 07/16/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 7/16/2014 10:34:53 AM PROVIDE CITY STAMPED APPROVED PLANS GFOR INSPECTION.
HVAC ROUGH 07/16/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 7/16/2014 10:34:53 AM MATERIAL AND DUCT LO9CATIONS DO NO MATCH APPROVED PLANS.
FRAMING 07/16/2014 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 7/16/2014 10:34:54 AM MISSING ATTACHMENT SCREWS. MULTIPLE LOCATIONS. INSTALL BRACING AND END WALL/CORNER WALL CONNECTIONS TO APPROVED PLANS DETAILS.
LATH/BRICK/WATER BARRIER 06/16/2014 APPROVED - AS NOTED CMINI
Note: PER CONTRACTOR Inspection Resulted at 6/16/2014 8:52:06 AM PER REVISION
PLUMBING 2ND ROUGH 06/16/2014 APPROVED - AS NOTED CMINI
Note: per contractor/BATH ROOM PLUMBING Inspection Resulted at 6/16/2014 8:52:06 AM PER REVISION
FRAMING 06/05/2014 PARTIALLY APPROVED CMINI
Note: doors /windows Inspection Resulted at 6/5/2014 2:30:56 PM EXTERIOR FRAMING
MONOLITHIC SLAB 01/21/2014 APPROVED RMARVEL
PLUMBING 1ST ROUGH 01/13/2014 APPROVED - AS NOTED RMARVEL
Note: Inspection Resulted at 1/13/2014 3:42:39 PM DWV HAS BEEN TESTED FOR 5FT OF HEAD PRESSURE AT 1ST ROUGH TO ABOVE FIXTURE PLACEMENT.

Review History

Department Status Date In Date Out
BLD COMPLETE 09/16/2015 09/17/2015
BLD HOLD 09/14/2015 09/15/2015
Note: 1. The revised elevation details for the grab bars does not match the toilet accessories chart for TA-4. J. Hindman 986-3784.
ELEC COMPLETE 09/01/2015 09/02/2015
ELEC HOLD 08/26/2015 08/31/2015
Note: 1. Provide electrical contractors name and license number on the drawings with the panel and wire sizes listed on the correction form. 5th. ed FBC 107.1 J. Hindman 986-3784.
BLD COMPLETE 01/12/2015 01/13/2015
FI1 COMPLETE 01/12/2015 01/13/2015
MECH COMPLETE 09/24/2014 09/30/2014
MECH HOLD 08/13/2014 08/14/2014
Note: provide revised floor plan removing dryer if exhaust vent is not being installed. Dryer on location must have exhaust vent.
ELEC COMPLETE 08/07/2014 08/07/2014
MECH HOLD 08/07/2014 08/07/2014
Note: Identify dryer exhaust system to comply with FMC504.1
BLD COMPLETE 07/30/2014 07/30/2014
ELEC COMPLETE 07/30/2014 07/30/2014
BLD HOLD 07/25/2014 07/25/2014
Note: Provide locations of changes by clouds or dated diamonds FBC 107.2.1
ELEC HOLD 07/25/2014 07/25/2014
Note: Provide locations of changes by clouds or dated diamonds FBC 107.2.1
MECH COMPLETE 07/25/2014 07/25/2014
PLUM COMPLETE 06/03/2014 06/03/2014
Note: Revision- duplication-same revision on bathroom.
FI1 COMPLETE 05/28/2014 06/02/2014
PLUM COMPLETE 05/28/2014 05/28/2014
Note: Revision - changed bathroom facilities
DSD COMPLETE 05/28/2014 06/02/2014
BLD COMPLETE 05/28/2014 05/29/2014
DSD HOLD 05/13/2014 05/14/2014
Note: 1. Please provide documents from the Condo Association, showing that the condo unit owner has been legally authorized to make the proposed changes to the exterior of the building. Typically, the Condo Association is the owner of the exterior of a condo building, thus they must approve of and authorize others to perform such work.
FI1 HOLD 05/13/2014 05/13/2014
Note: 1. Provide a new floorplan that shows the reconfigured space. J. Hindman 986-3784.
PLUM HOLD 05/13/2014 05/13/2014
Note: Revision calls for the removal of shower at office bathroom as the plan shows but the sanitary riser diagram still shows the shower. Coordinate and submit correction per 2010 FBC 107.2.1. Also, any the revision of sanitary riser diagram shall be signed by the engineer who originally designed the plumbing system for this job per FS 489.
BLD HOLD 05/12/2014 05/13/2014
Note: 1. Revise floorplan to show the reconfigured bathroom changes. 2010 FBC 107.2.1.
FI1 COMPLETE 03/27/2014 03/28/2014
ZON COMPLETE 03/27/2014 06/02/2014
BLD HOLD 03/26/2014 03/27/2014
Note: Show all door and window modifications and all elevations that are affected to include details of modified store fronts. FBC 107.2.1
PLUM COMPLETE 01/10/2014 01/10/2014
Note: Revision - changed sanitary/grease layout.
MECH COMPLETE 09/24/2013 09/24/2013
FI1 COMPLETE 09/24/2013 09/24/2013
BLD COMPLETE 09/24/2013 09/24/2013
UD1 COMPLETE 09/24/2013 09/25/2013
ELEC COMPLETE 09/24/2013 09/24/2013
BLD HOLD 09/09/2013 09/09/2013
Note: 1. provide panic hardware on the egress doors. 2010 FBC 1008.1.10. 2. Provide Florida product approval for the new exterior doors 2010 FBC 107.2.1. 3. Provide typical wall and soffit framing details that show how the walls and soffits are to be braced or attached to the structure. 2010 FBC 107.2.1.
ELEC COMPLETE 09/09/2013 09/09/2013
FI1 HOLD 09/09/2013 09/09/2013
Note: 1. Provide panic hardware on the egress doors.. 2. Provide a type K extinguisher in the kitchen. 3. (Note seperate permits will be required for the hood, fire sprinkler and fire alarm.)
MECH HOLD 09/09/2013 09/09/2013
Note: 1. Kitchen exhaust hood shall be applied under separate permit per 2010 FBC 107.2.1. 2. Provide energy calculations per 2010 FBC 107.3.5. 3. Provide gas riser diagram and gas subcontractor per 2010 FBC 107.2.1.
PLUM COMPLETE 09/09/2013 09/09/2013
SW1 COMPLETE 09/09/2013 09/09/2013
UD1 HOLD 09/09/2013 09/10/2013
Note: Provide completed DBPR form. Contact Utility Department to answer any questions (986-2355)
ZON COMPLETE 09/09/2013 09/12/2013

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/18/2015
REVISION ¤40.00 09/18/2015
REINSPECTION FEE ¤40.00 09/08/2015
REINSPECTION FEE ¤40.00 09/08/2015
REINSPECTION FEE ¤40.00 09/08/2015
REVISION ¤40.00 08/20/2015
REVISION ¤40.00 08/20/2015
REVISION ¤40.00 08/20/2015
REVISION ¤40.00 08/20/2015
REVISION ¤40.00 08/20/2015
EXTENSION ¤40.00 08/20/2015
REINSPECTION FEE ¤40.00 08/20/2015
REINSPECTION FEE ¤40.00 08/20/2015
REINSPECTION FEE ¤40.00 08/20/2015
REINSPECTION FEE ¤40.00 08/20/2015
FIRE PLANS REVIEW ¤25.00 09/30/2013
MECHANICAL FEE ¤171.00 09/30/2013
PLAN CHECK FEE ¤212.75 09/30/2013
PLUMBING FEE ¤171.00 09/30/2013
SITE PLAN 20 ¤20.00 09/30/2013
SURCHARGE FS 533.721 ¤31.21 09/30/2013
SURCHARGE - FS 468.631 ¤31.21 09/30/2013
ADMIN COMMERCIAL ¤60.00 09/30/2013
INSPECTION - COMMERCIAL ADD ¤1,295.00 09/30/2013
ELECTRIC FEE ¤171.00 09/30/2013
Fees Total Due: ¤0.00 Total Paid: ¤2,788.17